Hamzah Bany-Ata
Hamzah Bany-Ata
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hamzah Bany-Ata has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Ammar Bany-Ata
Mechanical Engineering Department, American University of Madaba (AUM), Madaba 11821, Jordan
2 shared publications - Sameeh Baqain
Mechanical Engineering Department, American University of Madaba (AUM), Madaba 11821, Jordan
2 shared publications Hussein Kokash
1 shared publication- Hussein Kokash
Mechanical Engineering Department, American University of Madaba (AUM), Madaba 11821, Jordan
1 shared publication Mwafak Shakoor
1 shared publication- Mwafak Shakoor
Mechanical Engineering Department, American University of Madaba (AUM), Madaba 11821, Jordan
1 shared publication
Latest Publications
- Open Access
- 3 August 2026
- Published by MDPI AG in Clean Technologies
- Vol. 8 (4) , 120
Dynamic Exergoenvironmental Priority Inversion in Power-to-Ammonia-to-Power Systems: The Static T0 Fallacy in Hot-Arid Climates
Power-to-Ammonia-to-Power (P2A2P) systems in hot-arid MENA climates reject waste heat through Recuperated Organic Rankine Cycles (RORCs) whose condensation temperature tracks ambient conditions across annual swings exceeding 35 K. Standard exergoenvironmental assessments evaluate priorities at a single dead-state temperature, an assumption this study terms the Static Fallacy. A four-way advanced exergy decomposition is combined with an off-design model (Stodola’s ellipse, constant- scaling) to sweep the dead-state temperature from C to C. At C, 95.8% of total exergy destruction is endogenous, confirming weak inter-component coupling. The condenser carries the largest avoidable environmental impact rate (4.02 mPts/h, 74% of the system total). At C, the recuperator undergoes a priority inversion from destruction-dominated () to fully capital-dominated (). Ammonia’s wet-fluid thermodynamic coupling eliminates the recuperator’s duty as the condensation temperature approaches the cold-side outlet constraint. The recuperator’s avoidable environmental impact rate drops by 100% relative to the standard assessment, while the condenser’s rises by 49%. This inversion mechanism is fluid-specific: the ammonia recuperator’s endogenous fraction reaches 99.5% at C. The toluene recuperator, swept at its own independently optimised operating point, has an endogenous fraction between 59.08% and 82.31% over the same range. For P2A2P installations where the annual ambient swing exceeds 15 K, exergoenvironmental analysis should be performed at both design-season and summer-peak dead-state temperatures, with the summer-peak result governing capital allocation.- 3 August 2026
- Published by MDPI AG in Clean Technologies
- Vol. 8 (4) , 120
Open AccessDynamic Exergoenvironmental Priority Inversion in Power-to-Ammonia-to-Power Systems: The Static T0 Fallacy in Hot-Arid Climates
Power-to-Ammonia-to-Power (P2A2P) systems in hot-arid MENA climates reject waste heat through Recuperated Organic Rankine Cycles (RORCs) whose condensation temperature tracks ambient conditions across annual swings exceeding 35 K. Standard exergoenvironmental assessments evaluate priorities at a single dead-state temperature, an assumption this study terms the Static Fallacy. A four-way advanced exergy decomposition is combined with an off-design model (Stodola’s ellipse, constant- scaling) to sweep the dead-state temperature from C to C. At C, 95.8% of total exergy destruction is endogenous, confirming weak inter-component coupling. The condenser carries the largest avoidable environmental impact rate (4.02 mPts/h, 74% of the system total). At C, the recuperator undergoes a priority inversion from destruction-dominated () to fully capital-dominated (). Ammonia’s wet-fluid thermodynamic coupling eliminates the recuperator’s duty as the condensation temperature approaches the cold-side outlet constraint. The recuperator’s avoidable environmental impact rate drops by 100% relative to the standard assessment, while the condenser’s rises by 49%. This inversion mechanism is fluid-specific: the ammonia recuperator’s endogenous fraction reaches 99.5% at C. The toluene recuperator, swept at its own independently optimised operating point, has an endogenous fraction between 59.08% and 82.31% over the same range. For P2A2P installations where the annual ambient swing exceeds 15 K, exergoenvironmental analysis should be performed at both design-season and summer-peak dead-state temperatures, with the summer-peak result governing capital allocation.