Jialin Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jialin Huang has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Can Mo
Shenzhen Campus of Sun Yat-sen University
2 shared publications- Shuai Hu
Shenzhen Campus of Sun Yat-sen University
2 shared publications - Tengda Zhang
Heidelberg University
2 shared publications - Yong-Sheng Huang
Sun Yat-sen University
2 shared publications Yuanchun Ye
Shenzhen Campus of Sun Yat-sen University
2 shared publications- Yuanjie Bi
Shenzhen Campus of Sun Yat-sen University
2 shared publications
Latest Publications
- Open Access
- 25 November 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (22) , 225023
A concentration-source-driven and GPU-accelerated standalone radiochemistry framework for continuous water radiolysis and pulse-structure simulation
Objective. Radiochemistry modeling plays a critical role in understanding the evolution of radiolytic species and their potential role in radiation-induced biological responses. Conventional Monte Carlo approaches can resolve early non-homogeneous chemistry, but their direct use in long-time, large-volume, or multi-pulse chemical-stage simulations is limited by high computational cost and boundary-condition constraints. This study aims to develop a GPU-accelerated, standalone radiochemistry framework driven by species concentration distribution sources (SCDS), enabling continuous water radiolysis modeling from the early non-homogeneous stage to the homogeneous stage and supporting flexible construction of pulse structures. Approach. SCDS were generated from Geant4-DNA simulations at t start = 5 ns and used as source terms for subsequent reaction–diffusion calculations. A concentration-dependent correction (CDC), fitted as a function of the local reactant concentration product, was incorporated to account for non-homogeneous reaction kinetics not captured by classical mass-action reaction–diffusion equations (RDEs). A 1 nm minimum reaction unit and a dual-grid GPU implementation were used to preserve simulation accuracy while ensuring efficiency. The model was benchmarked against Geant4-DNA for 50 and 500 MeV protons, 100 MeV u − 1 4 He ions and 200 MeV u − 1 12 C ions, and was used to simulate inter-track effects and macro-pulse irradiation. Main results. The fitted CDC functions captured the concentration-dependent kinetic discrepancy with R 2 > 0.99 for representative reactions and became negligible in the low-concentration regime, thereby recovering classical RDE kinetics. Using a single set of CDC functions, RDEs-extended reproduced Geant4-DNA time-dependent G -values for 50 and 500 MeV protons, 100 MeV u − 1 4 He ions and 200 MeV u − 1 12 C ions, with most species showing deviations within ± 5 % at 1 μ s . The GPU-accelerated implementation reduced computation time by 193.74 – 1191.37 × for the 1 μ s benchmark cases. Pulse-structure simulations showed stronger depletion of e aq − and OH − under shorter source separation and higher dose per pulse, indicating enhanced radical overlap and recombination. Significance. This work establishes an SCDS-driven, GPU-accelerated radiochemistry framework for continuous chemical-stage simulation of water radiolysis. The framework improves computational efficiency, reduces dependence on incident-particle tracking and boundary conditions, and supports pulse-structure simulations for studying radiolytic species evolution. The proposed model provides an efficient and extensible tool for simulating pulsed radiochemistry in realistic radiotherapy scenarios.
- 25 November 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (22) , 225023
Open AccessA concentration-source-driven and GPU-accelerated standalone radiochemistry framework for continuous water radiolysis and pulse-structure simulation
Objective. Radiochemistry modeling plays a critical role in understanding the evolution of radiolytic species and their potential role in radiation-induced biological responses. Conventional Monte Carlo approaches can resolve early non-homogeneous chemistry, but their direct use in long-time, large-volume, or multi-pulse chemical-stage simulations is limited by high computational cost and boundary-condition constraints. This study aims to develop a GPU-accelerated, standalone radiochemistry framework driven by species concentration distribution sources (SCDS), enabling continuous water radiolysis modeling from the early non-homogeneous stage to the homogeneous stage and supporting flexible construction of pulse structures. Approach. SCDS were generated from Geant4-DNA simulations at t start = 5 ns and used as source terms for subsequent reaction–diffusion calculations. A concentration-dependent correction (CDC), fitted as a function of the local reactant concentration product, was incorporated to account for non-homogeneous reaction kinetics not captured by classical mass-action reaction–diffusion equations (RDEs). A 1 nm minimum reaction unit and a dual-grid GPU implementation were used to preserve simulation accuracy while ensuring efficiency. The model was benchmarked against Geant4-DNA for 50 and 500 MeV protons, 100 MeV u − 1 4 He ions and 200 MeV u − 1 12 C ions, and was used to simulate inter-track effects and macro-pulse irradiation. Main results. The fitted CDC functions captured the concentration-dependent kinetic discrepancy with R 2 > 0.99 for representative reactions and became negligible in the low-concentration regime, thereby recovering classical RDE kinetics. Using a single set of CDC functions, RDEs-extended reproduced Geant4-DNA time-dependent G -values for 50 and 500 MeV protons, 100 MeV u − 1 4 He ions and 200 MeV u − 1 12 C ions, with most species showing deviations within ± 5 % at 1 μ s . The GPU-accelerated implementation reduced computation time by 193.74 – 1191.37 × for the 1 μ s benchmark cases. Pulse-structure simulations showed stronger depletion of e aq − and OH − under shorter source separation and higher dose per pulse, indicating enhanced radical overlap and recombination. Significance. This work establishes an SCDS-driven, GPU-accelerated radiochemistry framework for continuous chemical-stage simulation of water radiolysis. The framework improves computational efficiency, reduces dependence on incident-particle tracking and boundary conditions, and supports pulse-structure simulations for studying radiolytic species evolution. The proposed model provides an efficient and extensible tool for simulating pulsed radiochemistry in realistic radiotherapy scenarios.
- 30 June 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (13) , 135001
Development and characterization of a 1–2 MeV electron beam platform with magnetic focusing and steering for shallow high-dose-rate irradiation
Objective. To develop and experimentally characterize a 1–2 MeV electron linac platform with magnetic focusing and steering for superficial FLASH-compatible irradiation and electronically tunable spatial dose modulation. Approach. A preclinical 1–2 MeV electron linac was equipped with a solenoid for magnetic focusing and nested saddle-type scanning magnets for two-dimensional beam steering. Three-dimensional magnetic-field maps were computed in Opera and imported into a TOPAS Monte Carlo (MC) model incorporating the accelerator geometry, titanium exit foil, air gap, and water phantom for dose scoring. Dose distributions were measured using Gafchromic EBT-XD film. Film measurements of spot size, lateral dose profiles, and percentage depth-dose curves were compared with MC simulations. Multi-spot dose patterns were generated by varying scanning-magnet field strength, and peak spacing, peak-to-valley dose ratio, and dose rate as a function of repetition frequency were quantified. Main Results. In the solenoid-focused configuration, the beam size at the 80% isodose diameter was reduced from approximately 6 cm without solenoid focusing to 2 cm, and the measured dose rate reached 125 Gy s − 1 at 50 Hz. The measured full-width-at-half-maximum of the focused beam was 1.26 cm in the X direction and 1.39 cm in the Y direction, and the TOPAS model agreed with EBT-XD film measurements to within about 4% in the high-dose region. Magnetic steering generated tunable three-spot shallow dose distributions with peak-to-peak spacing up to approximately 2.9 cm and a maximum peak-to-valley dose ratio of 28.0. By superposition of adjacent scanned beam positions, the system also produced a broadened shallow field with a 95% D max flat-top width of 2.46 cm. Significance. The results demonstrate that a compact low-energy electron linac can provide a useful platform for studying FLASH-compatible superficial irradiation and electronically controlled spatial dose modulation in a regime where shallow dose confinement is advantageous.
- 30 June 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (13) , 135001
Development and characterization of a 1–2 MeV electron beam platform with magnetic focusing and steering for shallow high-dose-rate irradiation
Objective. To develop and experimentally characterize a 1–2 MeV electron linac platform with magnetic focusing and steering for superficial FLASH-compatible irradiation and electronically tunable spatial dose modulation. Approach. A preclinical 1–2 MeV electron linac was equipped with a solenoid for magnetic focusing and nested saddle-type scanning magnets for two-dimensional beam steering. Three-dimensional magnetic-field maps were computed in Opera and imported into a TOPAS Monte Carlo (MC) model incorporating the accelerator geometry, titanium exit foil, air gap, and water phantom for dose scoring. Dose distributions were measured using Gafchromic EBT-XD film. Film measurements of spot size, lateral dose profiles, and percentage depth-dose curves were compared with MC simulations. Multi-spot dose patterns were generated by varying scanning-magnet field strength, and peak spacing, peak-to-valley dose ratio, and dose rate as a function of repetition frequency were quantified. Main Results. In the solenoid-focused configuration, the beam size at the 80% isodose diameter was reduced from approximately 6 cm without solenoid focusing to 2 cm, and the measured dose rate reached 125 Gy s − 1 at 50 Hz. The measured full-width-at-half-maximum of the focused beam was 1.26 cm in the X direction and 1.39 cm in the Y direction, and the TOPAS model agreed with EBT-XD film measurements to within about 4% in the high-dose region. Magnetic steering generated tunable three-spot shallow dose distributions with peak-to-peak spacing up to approximately 2.9 cm and a maximum peak-to-valley dose ratio of 28.0. By superposition of adjacent scanned beam positions, the system also produced a broadened shallow field with a 95% D max flat-top width of 2.46 cm. Significance. The results demonstrate that a compact low-energy electron linac can provide a useful platform for studying FLASH-compatible superficial irradiation and electronically controlled spatial dose modulation in a regime where shallow dose confinement is advantageous.