Feifei Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Feifei Zhao has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Alexander L. Klibanov
Department of Medicine, Cardiovascular Division and Robert M. Berne Cardiovascular Research Center, University of Virginia, Charlottesville, VA, USA
1 shared publication- F. William Mauldin
Rivanna Medical, Charlottesville, VA, USA
1 shared publication - John A. Hossack
University of Virginia
1 shared publication - Yanjun Xie
Department of Biomedical Engineering, University of Virginia, Charlottesville, VA, USA
1 shared publication - Yi Huang
Department of Biomedical Engineering, University of Virginia, Charlottesville, VA, USA
1 shared publication
Latest Publications
- 4 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics
- Vol. 73 (4) , 445-459
High-Resolution Ultrasound Molecular Imaging With Incremental Burst Sequence: In Vitro and in Vivo Validation
Ultrasound localization microscopy (ULM) enables super-resolution ultrasound (SRUS) imaging of microvasculature, while ultrasound molecular imaging (USMI) characterizes molecular signatures using microbubbles (MBs) targeted to specific biomarkers. Although the co-localization of SRUS and USMI has been demonstrated previously, USMI resolution is limited by ultrasound diffraction-based effects and does not match the super-resolved microvasculature. This study introduces the Incremental Burst Sequence (IBS) method to induce the population of polydisperse targeted MBs to burst progressively, achieving MBs spatial separation and enabling high-resolution USMI (HR-USMI) localization. IBS method employs interleaved imaging and bursting pulses, with transmit voltages of bursting pulses incrementally increased to produce a gradual rise in the acoustic pressure. IBS is first validated optically in vitro using a cellulose tubing phantom, and MB remaining count during IBS is measured. Thereafter, in vivo validation is performed in a murine tumor model, and the intra-tumoral targeted MB signal intensity is measured during IBS. Furthermore, high frame-rate data for SRUS and IBS data for HR-USMI are acquired from a single bolus injection of MBs to generate composite images with high-resolution molecular signatures superimposed on the tumor microvasculature. Both in vitro and in vivo results validate the technical feasibility of the proposed IBS method. In addition, we demonstrate that higher bursting pulse repetitions lead to a faster disruption of the MB population during IBS. Finally, HR-USMI signals localized within a 50 μm × 50 μm grid are aligned with microvessels resolved better than 100 μm, presenting a combination of molecular signatures and anatomical structures at fine resolution.
- 4 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics
- Vol. 73 (4) , 445-459
High-Resolution Ultrasound Molecular Imaging With Incremental Burst Sequence: In Vitro and in Vivo Validation
Ultrasound localization microscopy (ULM) enables super-resolution ultrasound (SRUS) imaging of microvasculature, while ultrasound molecular imaging (USMI) characterizes molecular signatures using microbubbles (MBs) targeted to specific biomarkers. Although the co-localization of SRUS and USMI has been demonstrated previously, USMI resolution is limited by ultrasound diffraction-based effects and does not match the super-resolved microvasculature. This study introduces the Incremental Burst Sequence (IBS) method to induce the population of polydisperse targeted MBs to burst progressively, achieving MBs spatial separation and enabling high-resolution USMI (HR-USMI) localization. IBS method employs interleaved imaging and bursting pulses, with transmit voltages of bursting pulses incrementally increased to produce a gradual rise in the acoustic pressure. IBS is first validated optically in vitro using a cellulose tubing phantom, and MB remaining count during IBS is measured. Thereafter, in vivo validation is performed in a murine tumor model, and the intra-tumoral targeted MB signal intensity is measured during IBS. Furthermore, high frame-rate data for SRUS and IBS data for HR-USMI are acquired from a single bolus injection of MBs to generate composite images with high-resolution molecular signatures superimposed on the tumor microvasculature. Both in vitro and in vivo results validate the technical feasibility of the proposed IBS method. In addition, we demonstrate that higher bursting pulse repetitions lead to a faster disruption of the MB population during IBS. Finally, HR-USMI signals localized within a 50 μm × 50 μm grid are aligned with microvessels resolved better than 100 μm, presenting a combination of molecular signatures and anatomical structures at fine resolution.