Shi’En Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shi’En Zhang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Changhao Wei
Shaanxi Key Laboratory of Safety and Durability of Concrete Structures, Xijing University, Xi’an 710123, China
4 shared publications - Jian Wu
Shaanxi Key Laboratory of Safety and Durability of Concrete Structures, Xijing University, Xi’an 710123, China
4 shared publications - Weigao Ding
School of Infrastructure Engineering, Dalian University of Technology, Dalian 116024, China
3 shared publications - Chunjuan Zhou
Shaanxi Architectural Design and Research Institute (Group) Co., Ltd., Xi’an 710003, China
2 shared publications - Chaoqun Hu
Shaanxi Key Laboratory of Safety and Durability of Concrete Structures, Xijing University, Xi’an 710123, China
1 shared publication - Hongyang Yu
Shaanxi Key Laboratory of Safety and Durability of Concrete Structures, Xijing University, Xi’an 710123, China
1 shared publication
Latest Publications
- Open Access
Seismic Performance Test and Finite-Element Analysis of T-Shaped Steel Plate Connection for Strengthening Reinforced Concrete Beam–Column Joints
To enhance the seismic performance of existing reinforced concrete (RC) buildings during retrofitting, the study introduces a new type of joint connected by a T-shaped steel plate. Compared with previous similar strengthening methods, this novel structure incorporating a post-installed beam not only effectively improves the mechanical properties of RC columns, but the connectors also further enhance the integrity of the post-installed beam. Low-cycle reversed loading tests on one cast-in-place specimen (RC) and three T-shaped steel plate connection specimens (TRC1–TRC3) were conducted to evaluate failure modes, hysteresis and skeleton curves, and energy dissipation. Results show that the novel joint failure concentrates at beam-end–column steel jacket weld seams and column-side steel plate cracking, while the core-zone concrete remains intact. Compared with RC, the novel joints TRC1–TRC3 exhibit bearing capacity variations of −1.03%~+15.80% and significantly enhanced energy dissipation. The thickness of the beam’s wrapped steel improves the carrying capacity and energy dissipation, whereas the T-shaped connector thickness has limited influence on bearing capacity. ABAQUS parametric analysis indicates that bolt quantity, concrete strength, and connector thickness have limited influence and serve as secondary design factors. These findings provide a theoretical basis for retrofitting existing buildings.
Open AccessSeismic Performance Test and Finite-Element Analysis of T-Shaped Steel Plate Connection for Strengthening Reinforced Concrete Beam–Column Joints
To enhance the seismic performance of existing reinforced concrete (RC) buildings during retrofitting, the study introduces a new type of joint connected by a T-shaped steel plate. Compared with previous similar strengthening methods, this novel structure incorporating a post-installed beam not only effectively improves the mechanical properties of RC columns, but the connectors also further enhance the integrity of the post-installed beam. Low-cycle reversed loading tests on one cast-in-place specimen (RC) and three T-shaped steel plate connection specimens (TRC1–TRC3) were conducted to evaluate failure modes, hysteresis and skeleton curves, and energy dissipation. Results show that the novel joint failure concentrates at beam-end–column steel jacket weld seams and column-side steel plate cracking, while the core-zone concrete remains intact. Compared with RC, the novel joints TRC1–TRC3 exhibit bearing capacity variations of −1.03%~+15.80% and significantly enhanced energy dissipation. The thickness of the beam’s wrapped steel improves the carrying capacity and energy dissipation, whereas the T-shaped connector thickness has limited influence on bearing capacity. ABAQUS parametric analysis indicates that bolt quantity, concrete strength, and connector thickness have limited influence and serve as secondary design factors. These findings provide a theoretical basis for retrofitting existing buildings.
- Open Access
Seismic Behavior of Π-Shaped Connector RC Beam–Column Joints: Experimental and Numerical Investigation
Numerous existing RC frame buildings in China suffer from seismic deficiencies. This paper proposes a novel Π-shaped connector connection joint for the rapid strengthening of existing beam–column joints: steel plates are wrapped around existing columns, and Π-shaped connectors are welded to link new beam reinforcement. Quasi-static cyclic loading tests were conducted on one RC reference specimen and three strengthened specimens. The strengthened joints showed varying performance—two specimens (JGJ1 and JGJ2) exhibited peak loads below the RC reference, while the best specimen (JGJ3) achieved 9.8% enhancement in peak load and a nearly threefold increase in cumulative energy dissipation. The failure mode transitioned from brittle concrete crushing in the RC specimen to weld cracking and bolt fracture in the strengthened joints, thereby preserving the integrity of the core concrete. Finite element models were established using ABAQUS and validated against the test data. A parametric study investigated the effects of bolt quantity, beam and column dimensions, concrete strength, and steel plate thickness. The FE results indicate that increasing beam height from 400 mm to 450 mm yields the most significant improvement, with peak load increasing by up to 15.59% relative to the base parametric model. Favorable seismic performance was achieved with column concrete grade C50, beam concrete grade C40, steel plate thickness of 6 mm, eight bolts, and connector thickness of 6 mm. The proposed connection provides a potential strengthening alternative for existing RC frame structures.
Open AccessSeismic Behavior of Π-Shaped Connector RC Beam–Column Joints: Experimental and Numerical Investigation
Numerous existing RC frame buildings in China suffer from seismic deficiencies. This paper proposes a novel Π-shaped connector connection joint for the rapid strengthening of existing beam–column joints: steel plates are wrapped around existing columns, and Π-shaped connectors are welded to link new beam reinforcement. Quasi-static cyclic loading tests were conducted on one RC reference specimen and three strengthened specimens. The strengthened joints showed varying performance—two specimens (JGJ1 and JGJ2) exhibited peak loads below the RC reference, while the best specimen (JGJ3) achieved 9.8% enhancement in peak load and a nearly threefold increase in cumulative energy dissipation. The failure mode transitioned from brittle concrete crushing in the RC specimen to weld cracking and bolt fracture in the strengthened joints, thereby preserving the integrity of the core concrete. Finite element models were established using ABAQUS and validated against the test data. A parametric study investigated the effects of bolt quantity, beam and column dimensions, concrete strength, and steel plate thickness. The FE results indicate that increasing beam height from 400 mm to 450 mm yields the most significant improvement, with peak load increasing by up to 15.59% relative to the base parametric model. Favorable seismic performance was achieved with column concrete grade C50, beam concrete grade C40, steel plate thickness of 6 mm, eight bolts, and connector thickness of 6 mm. The proposed connection provides a potential strengthening alternative for existing RC frame structures.
- Open Access
Study on the Compressive Performance of Fabricated Reinforced Concrete Columns Strengthened with CFRP Sheets: Experimental and Finite Element Analysis
Fabricated reinforced concrete columns are important components of reinforced concrete structures. During the design reference period, columns are prone to degradation in mechanical and deformation properties, which affects the normal service of the structure. Based on compressive tests of fabricated reinforced concrete columns, this paper uses ABAQUS 2021 finite element analysis software to explore how factors such as column damage and CFRP sheet layout affect the compressive performance of fabricated concrete columns under eccentric compression in order to investigate their mechanical properties and the confinement effect of CFRP sheets on such columns. The results indicate that the change trend of the bearing capacity of the finite element model is largely in agreement with that of the test specimens, and the ultimate bearing capacity error is below 3%, thereby confirming the validity of the finite element model. Compared with strip confinement, full-wrap confinement achieves a greater improvement in ultimate bearing capacity, and two to three layers are recommended as the ideal number of CFRP sheets for strengthening. The maximum increase in ultimate bearing capacity can reach 19.18%. When the strip width is constant, the smaller the spacing, the smaller the concrete strain in the compression zone. When the net spacing is constant, reducing the strip width increases the number of cracks and decreases crack width, but reduces the ultimate bearing capacity of the column accordingly. Strengthening with CFRP sheets can enhance the ultimate bearing capacity, deformability, and ductility of columns with initial damage under both small and large eccentric compression. The maximum increase in ultimate bearing capacity can reach 8.31%. The results obtained in this paper are conducive to promoting the reinforcement and reconstruction of fabricated reinforced concrete columns and reinforced concrete structures.
Open AccessStudy on the Compressive Performance of Fabricated Reinforced Concrete Columns Strengthened with CFRP Sheets: Experimental and Finite Element Analysis
Fabricated reinforced concrete columns are important components of reinforced concrete structures. During the design reference period, columns are prone to degradation in mechanical and deformation properties, which affects the normal service of the structure. Based on compressive tests of fabricated reinforced concrete columns, this paper uses ABAQUS 2021 finite element analysis software to explore how factors such as column damage and CFRP sheet layout affect the compressive performance of fabricated concrete columns under eccentric compression in order to investigate their mechanical properties and the confinement effect of CFRP sheets on such columns. The results indicate that the change trend of the bearing capacity of the finite element model is largely in agreement with that of the test specimens, and the ultimate bearing capacity error is below 3%, thereby confirming the validity of the finite element model. Compared with strip confinement, full-wrap confinement achieves a greater improvement in ultimate bearing capacity, and two to three layers are recommended as the ideal number of CFRP sheets for strengthening. The maximum increase in ultimate bearing capacity can reach 19.18%. When the strip width is constant, the smaller the spacing, the smaller the concrete strain in the compression zone. When the net spacing is constant, reducing the strip width increases the number of cracks and decreases crack width, but reduces the ultimate bearing capacity of the column accordingly. Strengthening with CFRP sheets can enhance the ultimate bearing capacity, deformability, and ductility of columns with initial damage under both small and large eccentric compression. The maximum increase in ultimate bearing capacity can reach 8.31%. The results obtained in this paper are conducive to promoting the reinforcement and reconstruction of fabricated reinforced concrete columns and reinforced concrete structures.
- Open Access
Experimental and Finite Element Study on the Seismic Performance of Reinforced New-Type Joints: Adding Beams to Existing Columns
Currently, the development of civil engineering industry is gradually slowing down, with the focus gradually shifting toward the reinforcement and renovation of existing buildings. Among these existing structures, reinforced concrete (RC) structure is a kind of structure with high proportion. Therefore, this paper conducts research on the seismic properties of RC buildings after adding new beams to existing columns. This paper first introduces the design situation of the specimen, followed by an experimental investigation of its mechanical properties using pseudo-static tests. Based on the failure patterns and hysteresis curves, the differences between the new-type specimen and RC specimen are analyzed. The findings indicate that, while ensuring load-bearing capacity, the new-type joints exhibit better seismic performance: the bearing capacity and maximum displacement are increased by at most 9.2% and 14.9% respectively, and the fuller hysteresis curve shows that the new-type specimen has better energy dissipation capacity. Finally, this paper extends the analysis of the design parameters of the specimens using finite element components. The modeling results reveal that the bearing capacity varies by less than 1% with different parameters such as connector thickness, concrete strength grade, and bolts quantity and strength, indicating that these parameters have a relatively small impact on the bearing capacity. While for the specimen dimensions and thickness and strength of wrapped steel of beam, the maximum increase in bearing capacity is 32.3% and 6.0%, respectively. Indicating that their impact is quite significant. The findings of this paper provide a reference for structural design and contribute to advancing the work of reinforcement and renovation of existing concrete structures.
Open AccessExperimental and Finite Element Study on the Seismic Performance of Reinforced New-Type Joints: Adding Beams to Existing Columns
Currently, the development of civil engineering industry is gradually slowing down, with the focus gradually shifting toward the reinforcement and renovation of existing buildings. Among these existing structures, reinforced concrete (RC) structure is a kind of structure with high proportion. Therefore, this paper conducts research on the seismic properties of RC buildings after adding new beams to existing columns. This paper first introduces the design situation of the specimen, followed by an experimental investigation of its mechanical properties using pseudo-static tests. Based on the failure patterns and hysteresis curves, the differences between the new-type specimen and RC specimen are analyzed. The findings indicate that, while ensuring load-bearing capacity, the new-type joints exhibit better seismic performance: the bearing capacity and maximum displacement are increased by at most 9.2% and 14.9% respectively, and the fuller hysteresis curve shows that the new-type specimen has better energy dissipation capacity. Finally, this paper extends the analysis of the design parameters of the specimens using finite element components. The modeling results reveal that the bearing capacity varies by less than 1% with different parameters such as connector thickness, concrete strength grade, and bolts quantity and strength, indicating that these parameters have a relatively small impact on the bearing capacity. While for the specimen dimensions and thickness and strength of wrapped steel of beam, the maximum increase in bearing capacity is 32.3% and 6.0%, respectively. Indicating that their impact is quite significant. The findings of this paper provide a reference for structural design and contribute to advancing the work of reinforcement and renovation of existing concrete structures.