Hasnain Ali Shah
Hasnain Ali Shah has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Abdul Samad Saleem
National University of Singapore
1 shared publication - Asad Ullah
Department of Mechanical Engineering, University of Engineering and Technology, Mardan 23200, KPK, Pakistan
1 shared publication - Luqman Ali Khan
Department of Mechanical Engineering, University of Engineering and Technology
1 shared publication - Malik Sarmad Zahid
Department of Mechanical Engineering, University of Engineering and Technology
1 shared publication - Muhammad Ali
Department of Mechanical Engineering, University of Engineering and Technology, Mardan 23200, KPK, Pakistan
1 shared publication - Sana Ullah
Department of Mechanical Engineering, University of Engineering and Technology, Peshawar, Pakistan
1 shared publication
Latest Publications
- Open Access
- 2 July 2026
- Published by MDPI AG in Chemengineering
- Vol. 10 (7) , 84
Numerical Investigation of Fin-Enhanced Phase Change Material for Advanced Thermal Management of Lithium-Ion Batteries
This study presents a numerical investigation of a slit fin-enhanced phase change material (PCM)-based battery thermal management system (BTMS) for an 18650 cylindrical LiNixCoγMnzO2 lithium-ion battery. The proposed design modifies the conventional solid rectangular external fins by introducing four longitudinal slit fins with uniformly distributed rectangular through-thickness slot cutouts along the fin height. This modification increases the PCM-fin interfacial contact area and creates additional natural convective heat dissipation pathways from the PCM region to the ambient environment while maintaining the same BTMS envelope, PCM thickness, fin count, housing geometry, and material selection as the validated rectangular-fin baseline. The lumped-capacitance thermal model was used for battery heat generation, while the enthalpy-porosity approach was employed to model PCM melting. Simulations were performed in ANSYS Fluent 2024/R2 at 1C, 3C, 5C, and 7C discharge rates at an ambient temperature of 308.15 K. Paraffin wax PCM with a latent heat of approximately 240,000 J/kg was used. The rectangular fin model was first validated against the baseline study, achieving an average cell wall temperature error of 1.03% and a maximum error of 1.47% at 5C, while the total temperature and liquid fraction deviations remained below 0.73%, confirming the reliability of the numerical model. Mesh independence and temporal convergence studies further confirmed that the selected 0.50 mm polyhedral mesh and 0.5 s time step provided accurate and stable results. The results demonstrate that the slit fin geometry provides metric-dependent improvements in PCM utilization, thermal protection duration, and high-rate latent-heat activation rates. At 1C, both configurations remained well below the 318.15 K safety threshold, but the slit fin configuration maintained approximately 0.7 K lower total temperature at 2500 s and delayed PCM melting by about 300 s compared with rectangular fins, preserving more latent heat capacity for later thermal loading. At 3C, the slit fin design extended the thermal protection duration from 1650 s to 2500 s, corresponding to a 51.5% improvement, and increased PCM latent heat utilization from LF = 0.42 to LF = 0.49, representing a 16.7% increase. At 5C, slit fins initiated PCM melting approximately 3.5 times earlier, around 100 s, compared with 350–400 s for rectangular fins, and reached LF = 0.50 at 620 s, whereas rectangular fins reached only LF = 0.37 at 1480 s. This corresponds to approximately 2.87 times faster PCM utilization and 35.1% greater PCM melting. At 7C, the slit fin system again showed stronger PCM engagement, corresponding to 35.7% greater PCM utilization. Temperature and liquid fraction contours confirmed that the slit openings intensify localised PCM melting near the heat source, improve heat spreading through the PCM domain, and support natural convection-assisted melting. Overall, the slit-fin geometry provides a geometry-based enhancement for PCM utilization and thermal protection without changing system size or material selection for PCM-based BTMSs, improving latent heat utilization and thermal protection without increasing system size, PCM volume, or material complexity.
- 2 July 2026
- Published by MDPI AG in Chemengineering
- Vol. 10 (7) , 84
Open AccessNumerical Investigation of Fin-Enhanced Phase Change Material for Advanced Thermal Management of Lithium-Ion Batteries
This study presents a numerical investigation of a slit fin-enhanced phase change material (PCM)-based battery thermal management system (BTMS) for an 18650 cylindrical LiNixCoγMnzO2 lithium-ion battery. The proposed design modifies the conventional solid rectangular external fins by introducing four longitudinal slit fins with uniformly distributed rectangular through-thickness slot cutouts along the fin height. This modification increases the PCM-fin interfacial contact area and creates additional natural convective heat dissipation pathways from the PCM region to the ambient environment while maintaining the same BTMS envelope, PCM thickness, fin count, housing geometry, and material selection as the validated rectangular-fin baseline. The lumped-capacitance thermal model was used for battery heat generation, while the enthalpy-porosity approach was employed to model PCM melting. Simulations were performed in ANSYS Fluent 2024/R2 at 1C, 3C, 5C, and 7C discharge rates at an ambient temperature of 308.15 K. Paraffin wax PCM with a latent heat of approximately 240,000 J/kg was used. The rectangular fin model was first validated against the baseline study, achieving an average cell wall temperature error of 1.03% and a maximum error of 1.47% at 5C, while the total temperature and liquid fraction deviations remained below 0.73%, confirming the reliability of the numerical model. Mesh independence and temporal convergence studies further confirmed that the selected 0.50 mm polyhedral mesh and 0.5 s time step provided accurate and stable results. The results demonstrate that the slit fin geometry provides metric-dependent improvements in PCM utilization, thermal protection duration, and high-rate latent-heat activation rates. At 1C, both configurations remained well below the 318.15 K safety threshold, but the slit fin configuration maintained approximately 0.7 K lower total temperature at 2500 s and delayed PCM melting by about 300 s compared with rectangular fins, preserving more latent heat capacity for later thermal loading. At 3C, the slit fin design extended the thermal protection duration from 1650 s to 2500 s, corresponding to a 51.5% improvement, and increased PCM latent heat utilization from LF = 0.42 to LF = 0.49, representing a 16.7% increase. At 5C, slit fins initiated PCM melting approximately 3.5 times earlier, around 100 s, compared with 350–400 s for rectangular fins, and reached LF = 0.50 at 620 s, whereas rectangular fins reached only LF = 0.37 at 1480 s. This corresponds to approximately 2.87 times faster PCM utilization and 35.1% greater PCM melting. At 7C, the slit fin system again showed stronger PCM engagement, corresponding to 35.7% greater PCM utilization. Temperature and liquid fraction contours confirmed that the slit openings intensify localised PCM melting near the heat source, improve heat spreading through the PCM domain, and support natural convection-assisted melting. Overall, the slit-fin geometry provides a geometry-based enhancement for PCM utilization and thermal protection without changing system size or material selection for PCM-based BTMSs, improving latent heat utilization and thermal protection without increasing system size, PCM volume, or material complexity.
- 23 June 2026
- Published by Yildiz Technical University in Journal of Thermal Engineering
Energy and exergy analyses of a lab-scale open-cycle steam power plant at different boiler pressures
In contrast to conventional steam power plants, which employ high-pressure closed cycles, this study presents energy and exergy analyses of a non-conventional lab-scale steam power plant across different boiler pressures, with an emphasis on the effect of cycle openness. Energy loss from the condenser, turbine work, and thermal efficiency of the cycle have been investigated at different boiler pressures, using energy analysis. Exergy analysis is performed at varying boiler pressures to examine the exergy destruction in the boiler and the condenser, and to evaluate the cycle’s exergetic efficiency. Experimental results show that minimizing exergy loss in one component of the cycle by varying the boiler pressure may increase it in another component; therefore, an optimal boiler pressure was investigated. As boiler pressure increases, turbine work and efficiencies initially increase because of higher exergy input but subsequently decrease as exergy destruction rises. The optimum boiler pressure is around 2.6 bar, as it minimizes exergy destruction in the cycle and energy loss in the condenser. Because the exergy input is less than the corresponding heat input, the energy efficiency (5-6.5 %) is found to be lower than the exergetic efficiency (15-21 %). In contrast to previous literature on conventional closed-cycle power plants, the current study finds condenser exergy destruction (542-564 kJ/kg) higher than that of the boiler (20-98 kJ/kg); this is due to the lack of condensate recirculation and consequent exergy loss at the condenser’s open end.
- 23 June 2026
- Published by Yildiz Technical University in Journal of Thermal Engineering
Energy and exergy analyses of a lab-scale open-cycle steam power plant at different boiler pressures
In contrast to conventional steam power plants, which employ high-pressure closed cycles, this study presents energy and exergy analyses of a non-conventional lab-scale steam power plant across different boiler pressures, with an emphasis on the effect of cycle openness. Energy loss from the condenser, turbine work, and thermal efficiency of the cycle have been investigated at different boiler pressures, using energy analysis. Exergy analysis is performed at varying boiler pressures to examine the exergy destruction in the boiler and the condenser, and to evaluate the cycle’s exergetic efficiency. Experimental results show that minimizing exergy loss in one component of the cycle by varying the boiler pressure may increase it in another component; therefore, an optimal boiler pressure was investigated. As boiler pressure increases, turbine work and efficiencies initially increase because of higher exergy input but subsequently decrease as exergy destruction rises. The optimum boiler pressure is around 2.6 bar, as it minimizes exergy destruction in the cycle and energy loss in the condenser. Because the exergy input is less than the corresponding heat input, the energy efficiency (5-6.5 %) is found to be lower than the exergetic efficiency (15-21 %). In contrast to previous literature on conventional closed-cycle power plants, the current study finds condenser exergy destruction (542-564 kJ/kg) higher than that of the boiler (20-98 kJ/kg); this is due to the lack of condensate recirculation and consequent exergy loss at the condenser’s open end.