Leandro Sanches Sampaio
Research Subjects
Leandro Sanches Sampaio has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Luiz Vicente Gomes Tarelho
Dmtic - Inmetro - Av. Nossa Senhora das Graças, 50 - Xerém, Duque de Caxias, RJ - Brazil
1 shared publication - Mila Rosendahl Avelino
National Institute of Metrology, Quality and Technology - INMETRO, Xerém, Brazil
1 shared publication
Latest Publications
- Open Access
- 18 May 2026
- Published by IMEKO International Measurement Confederation in ACTA IMEKO
- Vol. 15 (2) , 1-11
On the microvolume measurement from 0.1 μL up to 100 mL using a microsyringe and micropipette
This work focuses on the measurement of small liquid volumes, comparing results obtained using the gravimetric method with different resolutions. The main objective of this study is to characterize the behaviour of microsyringes and micropipettes during the measurement of microvolumes in the range between 0.1 and 1 µL using the gravimetric method, with metrological traceability, and compare the results in the range up to 100 µL. The methodology addresses the challenges associated with measurements below 1 µL by establishing metrological traceability through mass measurement using the gravimetric method. Given that the smallest standard weight is nominally 1 mg, relying solely on the dispensed liquid volume would result in a lack of metrological traceability for volumes under 1 µL. To enhance reliability, eleven independent measurements are taken at each volume point to calculate an average. The results are presented, to conclude the analysis, and simulations were conducted to explore potential improvements by employing a scale with a resolution of 0.001 mg, along with its associated measurement uncertainty.
- 18 May 2026
- Published by IMEKO International Measurement Confederation in ACTA IMEKO
- Vol. 15 (2) , 1-11
Open AccessOn the microvolume measurement from 0.1 μL up to 100 mL using a microsyringe and micropipette
This work focuses on the measurement of small liquid volumes, comparing results obtained using the gravimetric method with different resolutions. The main objective of this study is to characterize the behaviour of microsyringes and micropipettes during the measurement of microvolumes in the range between 0.1 and 1 µL using the gravimetric method, with metrological traceability, and compare the results in the range up to 100 µL. The methodology addresses the challenges associated with measurements below 1 µL by establishing metrological traceability through mass measurement using the gravimetric method. Given that the smallest standard weight is nominally 1 mg, relying solely on the dispensed liquid volume would result in a lack of metrological traceability for volumes under 1 µL. To enhance reliability, eleven independent measurements are taken at each volume point to calculate an average. The results are presented, to conclude the analysis, and simulations were conducted to explore potential improvements by employing a scale with a resolution of 0.001 mg, along with its associated measurement uncertainty.