Ariel Fernandez-Pirez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ariel Fernandez-Pirez has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Anton Maksimenko
Australian Synchrotron, ANSTO, Clayton, VIC 3168, Australia
2 shared publications - Caroline Kachana Pwamang
University of Ghana, Accra, Ghana, Ghana
2 shared publications - Stevan Vrbaski
Faculty of Medicine, University of Novi Sad, 21137 Novi Sad, Serbia
2 shared publications - Luca Brombal
Department of Physics, University of Trieste 1 , Trieste
1 shared publication - Luca Brombal
University of Trieste, Trieste, Italy, Italy
1 shared publication - Luigi Rigon
University of Trieste
1 shared publication
Latest Publications
- Open Access
- 29 August 2026
- Published by MDPI AG in Tomography
- Vol. 12 (9) , 124
Radiomic Characterization of Breast Tissue from Breast CT Images Obtained with Synchrotron Beams
Background/Objective: Radiomics offers a powerful, non-invasive approach for extracting quantitative features to predict lesion phenotypes. This study performs a radiomic characterization of breast tissue using synchrotron radiation breast computed tomography (SR-bCT). Method: Four mastectomy samples were imaged at the Australian Synchrotron (ANSTO) using five energies (25, 32, 35, 40, and 60 keV). From 10 slices per energy for each sample, 1546 regions of interest (ROIs) were extracted across four tissue subtypes: fatty, glandular, fibrous, and microcalcified. Using Pyradiomics, 93 features were initially calculated and then reduced to 34, eliminating highly correlated variables to reduce redundancies. Seven linear regression models and a discriminant analysis evaluated subtype tissue separation and radiomic characterization across individuals and combined samples and energies with a good fit (0.81 ≤ R ≤ 0.98). Results: The study identified six possible robust exploratory candidate features independent of sample variability and energy levels, whose mean values are significantly different among the four tissue subtypes (clusters, p < 0.001). The selected candidate features were 90th Percentile, Kurtosis, Skewness, GLCM IDM, GLDM LDE, and NGTDM Coarseness. These metrics successfully differentiated all tissue pairs (microcalcifications/fat, microcalcifications/gland, microcalcifications/fiber, fat/gland, fat/fiber and gland/fiber), with p < 0.05 inside the most general regression model and p < 0.0001 with the linear discriminant separation in clusters. Conclusions: Findings indicate that some first-order and second-order texture metrics reflecting global dependencies remain stable across experimental conditions. Conversely, fine-texture metrics are highly sensitive to sample energy changes, limiting their generalizability. These results align with successful biomarkers in mammography and validate the potential of radiomics in SR-bCT characterization.
- 29 August 2026
- Published by MDPI AG in Tomography
- Vol. 12 (9) , 124
Open AccessRadiomic Characterization of Breast Tissue from Breast CT Images Obtained with Synchrotron Beams
Background/Objective: Radiomics offers a powerful, non-invasive approach for extracting quantitative features to predict lesion phenotypes. This study performs a radiomic characterization of breast tissue using synchrotron radiation breast computed tomography (SR-bCT). Method: Four mastectomy samples were imaged at the Australian Synchrotron (ANSTO) using five energies (25, 32, 35, 40, and 60 keV). From 10 slices per energy for each sample, 1546 regions of interest (ROIs) were extracted across four tissue subtypes: fatty, glandular, fibrous, and microcalcified. Using Pyradiomics, 93 features were initially calculated and then reduced to 34, eliminating highly correlated variables to reduce redundancies. Seven linear regression models and a discriminant analysis evaluated subtype tissue separation and radiomic characterization across individuals and combined samples and energies with a good fit (0.81 ≤ R ≤ 0.98). Results: The study identified six possible robust exploratory candidate features independent of sample variability and energy levels, whose mean values are significantly different among the four tissue subtypes (clusters, p < 0.001). The selected candidate features were 90th Percentile, Kurtosis, Skewness, GLCM IDM, GLDM LDE, and NGTDM Coarseness. These metrics successfully differentiated all tissue pairs (microcalcifications/fat, microcalcifications/gland, microcalcifications/fiber, fat/gland, fat/fiber and gland/fiber), with p < 0.05 inside the most general regression model and p < 0.0001 with the linear discriminant separation in clusters. Conclusions: Findings indicate that some first-order and second-order texture metrics reflecting global dependencies remain stable across experimental conditions. Conversely, fine-texture metrics are highly sensitive to sample energy changes, limiting their generalizability. These results align with successful biomarkers in mammography and validate the potential of radiomics in SR-bCT characterization.
- Open Access
- 10 July 2026
- Published by MDPI AG in Preprints.org
Radiomic Characterization of Breast Tissue from Breast CT Images Obtained with Synchrotron Beams
Backgroung / Objective: Radiomics offers a powerful, non-invasive approach for extracting quantitative features to predict lesion phenotypes. This study performs a radiomic characterization of breast tissue using synchrotron radiation breast computed tomography (SR-bCT). Method: Four mastectomy samples were imaged at the Australian Synchrotron (ANSTO) using five energies (25, 32, 35, 40, and 60 keV). From 10 slices per energy for each sample, 1546 regions of interest (ROIs) were extracted across four tissue subtypes: fatty, glandular, fibrous, and microcalcified. Using Pyradiomics, 93 features were initially calculated and then reduced to 34, eliminating highly correlated variables to reduce redundancies. Seven linear regression models and a discriminant analysis evaluated subtype tissue separation and radiomic characterization across individuals and combined samples and energies with a good fit (0.81≤ R ≤ 0.98). Results: The study identified 6 robust possible biomarkers independent of sample variability and energy levels, whose mean values are significantly different among the 4 tissue subtypes (clusters, p< 0.001). The selected biomarkers were: 90th Percentile, Kurtosis, Skewness, GLCM IDM, GLDM LDE, and NGTDM Coarseness. These metrics successfully differentiated all tissue pairs (microcalcifications/fat, microcalcifications/gland, microcalcifications/fiber, fat/gland, fat/fiber and gland/fiber), with p < 0.05 inside the most general regression model and p< 0.0001 with the linear discriminant separation in clusters. Conclusion: Findings indicate that some first-order and second-order texture metrics reflecting global dependencies remain stable across experimental conditions. Conversely, fine-texture metrics are highly sensitive to sample energy changes, limiting their generalizability. These results align with successful biomarkers in mammography and validate the potential of radiomics in SR-bCT characterization.
- 10 July 2026
- Published by MDPI AG in Preprints.org
Open AccessRadiomic Characterization of Breast Tissue from Breast CT Images Obtained with Synchrotron Beams
Backgroung / Objective: Radiomics offers a powerful, non-invasive approach for extracting quantitative features to predict lesion phenotypes. This study performs a radiomic characterization of breast tissue using synchrotron radiation breast computed tomography (SR-bCT). Method: Four mastectomy samples were imaged at the Australian Synchrotron (ANSTO) using five energies (25, 32, 35, 40, and 60 keV). From 10 slices per energy for each sample, 1546 regions of interest (ROIs) were extracted across four tissue subtypes: fatty, glandular, fibrous, and microcalcified. Using Pyradiomics, 93 features were initially calculated and then reduced to 34, eliminating highly correlated variables to reduce redundancies. Seven linear regression models and a discriminant analysis evaluated subtype tissue separation and radiomic characterization across individuals and combined samples and energies with a good fit (0.81≤ R ≤ 0.98). Results: The study identified 6 robust possible biomarkers independent of sample variability and energy levels, whose mean values are significantly different among the 4 tissue subtypes (clusters, p< 0.001). The selected biomarkers were: 90th Percentile, Kurtosis, Skewness, GLCM IDM, GLDM LDE, and NGTDM Coarseness. These metrics successfully differentiated all tissue pairs (microcalcifications/fat, microcalcifications/gland, microcalcifications/fiber, fat/gland, fat/fiber and gland/fiber), with p < 0.05 inside the most general regression model and p< 0.0001 with the linear discriminant separation in clusters. Conclusion: Findings indicate that some first-order and second-order texture metrics reflecting global dependencies remain stable across experimental conditions. Conversely, fine-texture metrics are highly sensitive to sample energy changes, limiting their generalizability. These results align with successful biomarkers in mammography and validate the potential of radiomics in SR-bCT characterization.