Gakuto Kagawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gakuto Kagawa has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Hidetoshi Takahashi
Keio University
2 shared publications Hinata Mitomo
Research Center for Advanced Science and Technology (RCAST), The University of Tokyo, Tokyo, Japan
1 shared publication- Hiroshi Arao
Department of Human Sciences, Taisho University, Tokyo, Japan
1 shared publication Hirotoshi Asano
College of Systems Engineering and Science, Shibaura Institute of Technology, Tokyo, Japan
1 shared publication- Huimin Gong
Research Center for Advanced Science and Technology (RCAST), The University of Tokyo, Tokyo, Japan
1 shared publication - Jiheong Kang
Seoul National University
1 shared publication
Latest Publications
- 6 November 2026
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 65 (21) , 216502
Dual-camera sampling moiré measurement of root-induced stress distribution using a phosphorescent agar grid
Plant root growth generates deformation and stress in the surrounding medium; however, measuring stress distribution remains challenging. In this study, a dual-camera sampling moiré system was developed using a phosphorescent grid agar medium. The same grid pattern was observed from both sides, and the images were independently analyzed to obtain in-plane displacement distributions, resulting in calculations of strain and stress distributions, with a noise level of 15 µm determined from static measurements over 3.5 d. The rod insertion experiments showed that partial grid blocking affected the displacement distribution, whereas the opposite view reproduced the overall spatial trend observed in the simulation. Finally, the method was demonstrated during radish sprout root growth, in which the complementary view compensated for partial grid blocking, enabling the evaluation of displacement, strain, and stress distributions. Therefore, this dual-view system enables root-induced stress distribution measurements while assessing the influence of partial grid blocking.
- 6 November 2026
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 65 (21) , 216502
Dual-camera sampling moiré measurement of root-induced stress distribution using a phosphorescent agar grid
Plant root growth generates deformation and stress in the surrounding medium; however, measuring stress distribution remains challenging. In this study, a dual-camera sampling moiré system was developed using a phosphorescent grid agar medium. The same grid pattern was observed from both sides, and the images were independently analyzed to obtain in-plane displacement distributions, resulting in calculations of strain and stress distributions, with a noise level of 15 µm determined from static measurements over 3.5 d. The rod insertion experiments showed that partial grid blocking affected the displacement distribution, whereas the opposite view reproduced the overall spatial trend observed in the simulation. Finally, the method was demonstrated during radish sprout root growth, in which the complementary view compensated for partial grid blocking, enabling the evaluation of displacement, strain, and stress distributions. Therefore, this dual-view system enables root-induced stress distribution measurements while assessing the influence of partial grid blocking.
- Open Access
- 15 July 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (29) , eaee6417
Reduction of appearance artifacts in wearable on-skin electronics.
Facial electrophysiological signals are crucial to human-machine interfaces and health care monitoring. Soft and skin-conformable electrodes enabled long-term and comfortable signal monitoring. However, the appearance of the electrodes affects the wearer's social interactions and self-identity, making daily usage difficult and leaving appearance artifacts. Here, we developed fully invisible and unperceivable on-skin electrodes free from appearance artifacts. Neither the wearer nor observers can detect the visual and tactile presence of the electrodes on the skin. The unperceivable property was confirmed with sensory experiments and physical characterizations of the film on skin. Furthermore, our invisible electrodes did not affect the psychological conditions of the wearers, which confirms the feasibility of artifact-free monitoring in daily lives. Last, we demonstrated the functionality of our electrode with successful monitoring of various facial electrophysiological signals, including electrooculogram (EOG), electromyogram (EMG), and electroencephalogram (EEG). Our fully invisible electrodes provide a promising direction in developing on-skin bioelectronics, seamlessly integrating health monitoring and human-computer interaction technologies into people's daily lives.
- 15 July 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (29) , eaee6417
Open AccessReduction of appearance artifacts in wearable on-skin electronics.
Facial electrophysiological signals are crucial to human-machine interfaces and health care monitoring. Soft and skin-conformable electrodes enabled long-term and comfortable signal monitoring. However, the appearance of the electrodes affects the wearer's social interactions and self-identity, making daily usage difficult and leaving appearance artifacts. Here, we developed fully invisible and unperceivable on-skin electrodes free from appearance artifacts. Neither the wearer nor observers can detect the visual and tactile presence of the electrodes on the skin. The unperceivable property was confirmed with sensory experiments and physical characterizations of the film on skin. Furthermore, our invisible electrodes did not affect the psychological conditions of the wearers, which confirms the feasibility of artifact-free monitoring in daily lives. Last, we demonstrated the functionality of our electrode with successful monitoring of various facial electrophysiological signals, including electrooculogram (EOG), electromyogram (EMG), and electroencephalogram (EEG). Our fully invisible electrodes provide a promising direction in developing on-skin bioelectronics, seamlessly integrating health monitoring and human-computer interaction technologies into people's daily lives.