Feng Yin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Feng Yin has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Di Lu
Department of Neurosurgery Aerospace Center Hospital Beijing China
2 shared publications - Mingming Zhao
Department of Neurosurgery Aerospace Center Hospital Beijing China
2 shared publications Xin Yan
Department of Neurosurgery Aerospace Center Hospital Beijing China
1 shared publicationZhitao Li
Department of Neurosurgery Huanhu Hospital Affiliated to Tianjin Medical University Tianjin China
1 shared publication
Latest Publications
- Open Access
- 8 July 2026
- Published by Oxford University Press (OUP) in Oxford Medical Case Reports
- Vol. 2026 (7)
Charging failure due to pulse generator rotation after deep brain stimulation: a case report
A 54-year-old man with Parkinson’s disease presented with gait instability and difficulty charging his rechargeable deep brain stimulation (DBS) pulse generator. Chest radiography revealed horizontal rotation and anterior-to-posterior inversion of the device within the subcutaneous pocket, which was not seen in prior imaging. Surgical revision confirmed the device malorientation, and repositioning restored charging efficiency. This case highlights that pulse generator rotation, a rare but relevant hardware complication, can cause charging difficulties despite normal device interrogation. It underscores the importance of considering mechanical causes and using chest imaging in postoperative assessments.
- 8 July 2026
- Published by Oxford University Press (OUP) in Oxford Medical Case Reports
- Vol. 2026 (7)
Open AccessCharging failure due to pulse generator rotation after deep brain stimulation: a case report
A 54-year-old man with Parkinson’s disease presented with gait instability and difficulty charging his rechargeable deep brain stimulation (DBS) pulse generator. Chest radiography revealed horizontal rotation and anterior-to-posterior inversion of the device within the subcutaneous pocket, which was not seen in prior imaging. Surgical revision confirmed the device malorientation, and repositioning restored charging efficiency. This case highlights that pulse generator rotation, a rare but relevant hardware complication, can cause charging difficulties despite normal device interrogation. It underscores the importance of considering mechanical causes and using chest imaging in postoperative assessments.