Kirill Lukianov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kirill Lukianov has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Arsenii Litvinov
Trusted AI Research Center, Russian Academy of Sciences, Moscow 109004, Russia
1 shared publication - Egor Ushakov
Trusted AI Research Center, Russian Academy of Sciences, Moscow 109004, Russia
1 shared publication - Evgeny Karpulevich
Trusted AI Research Center, Russian Academy of Sciences, Moscow 109004, Russia
1 shared publication - Sofia Senotrusova
Trusted AI Research Center, Russian Academy of Sciences, Moscow 109004, Russia
1 shared publication - Sofya N. Zimina
Lomonosov Moscow State University
1 shared publication - Tigran G. Gevorkyan
Federal State Budgetary Institution “N.N. Blokhin National Medical Research Center of Oncology” of the Ministry of Health of the Russian Federation, Moscow 115478, Russia
1 shared publication
Latest Publications
- Open Access
- 31 July 2026
- Published by MDPI AG in Informatics
- Vol. 13 (8) , 125
Optimizing the Mammography AI Pipeline: From Data Filtering to Vision-Language Models
The performance of AI solutions in mammography is largely determined by data quality, preprocessing methods, and augmentation strategies. However, systematic evaluation of these factors for models trained on aggregated multicenter datasets remains underexplored. This article presents a comparative assessment of the effects of different stages of the training pipeline on the final diagnostic accuracy. Using a pooled dataset (VinDr-Mammo, INBreast, CMMD, CBIS-DDSM), we evaluated each pipeline step—from filtering to architecture selection (EfficientNet-B3, CLIP). External testing was conducted on the MosMed database. Among the tested preprocessing steps, filtering the darkest 5% of images proved most effective. For EfficientNet-B3, optimal geometric and photometric augmentations increased test AUROC on the prepared MosMed test set from 0.844 to 0.900. Domain-specific pretraining and high resolution yielded the best performance: Mammo-CLIP achieved an AUROC of 0.949 ± 0.012, and EfficientNet-B3 reached 0.934 ± 0.013. Overall, this study developed a standardized pipeline that includes sequential data filtering and harmonization, augmentation optimization, and architecture selection. This approach ensures reliable and reproducible results for automated mammogram classification.
- 31 July 2026
- Published by MDPI AG in Informatics
- Vol. 13 (8) , 125
Open AccessOptimizing the Mammography AI Pipeline: From Data Filtering to Vision-Language Models
The performance of AI solutions in mammography is largely determined by data quality, preprocessing methods, and augmentation strategies. However, systematic evaluation of these factors for models trained on aggregated multicenter datasets remains underexplored. This article presents a comparative assessment of the effects of different stages of the training pipeline on the final diagnostic accuracy. Using a pooled dataset (VinDr-Mammo, INBreast, CMMD, CBIS-DDSM), we evaluated each pipeline step—from filtering to architecture selection (EfficientNet-B3, CLIP). External testing was conducted on the MosMed database. Among the tested preprocessing steps, filtering the darkest 5% of images proved most effective. For EfficientNet-B3, optimal geometric and photometric augmentations increased test AUROC on the prepared MosMed test set from 0.844 to 0.900. Domain-specific pretraining and high resolution yielded the best performance: Mammo-CLIP achieved an AUROC of 0.949 ± 0.012, and EfficientNet-B3 reached 0.934 ± 0.013. Overall, this study developed a standardized pipeline that includes sequential data filtering and harmonization, augmentation optimization, and architecture selection. This approach ensures reliable and reproducible results for automated mammogram classification.