Amir H. Shaker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Amir H. Shaker has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Arash Nazeri
Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO, United States
2 shared publications - Aristeidis Sotiras
University of Pennsylvania
2 shared publications - Bryn A. Martin
Department of Chemical and Biological Engineering, University of Idaho, Moscow, ID, United States
2 shared publications - Helia Hosseini
Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO, United States
2 shared publications Jennifer M. Strahle
Department of Neurosurgery, Washington University School of Medicine, St. Louis, MO, United States
2 shared publicationsAmir H.G. Arani
Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO, United States
1 shared publication
Latest Publications
- Open Access
- 22 September 2026
- Published by MIT Press in Imaging Neuroscience
- Vol. 4
Simultaneous real-time imaging of upper cervical cerebrospinal fluid and vascular dynamics using ultrafast inflow-weighted EPI
Cerebrospinal fluid (CSF) circulation is tightly coupled to cerebral blood flow under the fixed-volume constraint of the cranial vault, with cardiac pulsations and respiration acting as dominant physiological drivers. Disruption of these flow dynamics has been implicated in various neurological disorders, motivating the need for imaging methods that capture CSF and vascular flow simultaneously and in real time. Conventional phase contrast MRI (PC-MRI) provides quantitative CSF velocity measurements but relies on cardiac gating and velocity encoding, which limit temporal resolution, dynamic range, and sensitivity to non-cardiac fluctuations. Here, we implement a single-slice ultrafast inflow-weighted echo-planar imaging (EPI), in which signal intensity reflects the replacement of saturated spins by freshly inflowing, unsaturated water molecules, yielding higher signal with higher flow velocity. This allows simultaneous assessment of arterial inflow, venous outflow, and CSF motion at high temporal resolution. Ultrafast EPI was acquired at the C2–C3 spinal level, enabling real-time imaging of CSF flow dynamics in the cervical spinal canal alongside arterial and venous blood flow in major cervical vessels (frame rate: 21.7 Hz). Furthermore, intrinsic arterial signal fluctuations were leveraged as a timing reference to reconstruct cardiac-resolved CSF dynamics for individual cardiac cycles without external physiological recordings. Frequency-domain analysis revealed distinct spectral signatures in CSF flow compared with neurovascular flow, including broadened cardiac peaks and enhanced respiratory modulation, particularly within the ventral spinal canal. In contrast, dorsal CSF showed increased power within the cardiac frequency band, higher coherence with cervical vasculature at the cardiac frequency, and reduced non-cardiac contributions. Time-domain analysis showed strong correlation between CSF flow waveforms derived from ultrafast EPI and PC-MRI. Beyond ensemble-averaged waveforms, ultrafast EPI enabled beat-to-beat analysis, revealing substantial cycle-to-cycle variability in CSF flow that is not captured by time-averaged gated approaches. Together, these findings establish ultrafast EPI as a rapid, complementary framework to PC-MRI, enabling real-time neurofluid imaging with integrated time- and frequency-domain characterization of CSF and neurovascular flow dynamics.
- 22 September 2026
- Published by MIT Press in Imaging Neuroscience
- Vol. 4
Open AccessSimultaneous real-time imaging of upper cervical cerebrospinal fluid and vascular dynamics using ultrafast inflow-weighted EPI
Cerebrospinal fluid (CSF) circulation is tightly coupled to cerebral blood flow under the fixed-volume constraint of the cranial vault, with cardiac pulsations and respiration acting as dominant physiological drivers. Disruption of these flow dynamics has been implicated in various neurological disorders, motivating the need for imaging methods that capture CSF and vascular flow simultaneously and in real time. Conventional phase contrast MRI (PC-MRI) provides quantitative CSF velocity measurements but relies on cardiac gating and velocity encoding, which limit temporal resolution, dynamic range, and sensitivity to non-cardiac fluctuations. Here, we implement a single-slice ultrafast inflow-weighted echo-planar imaging (EPI), in which signal intensity reflects the replacement of saturated spins by freshly inflowing, unsaturated water molecules, yielding higher signal with higher flow velocity. This allows simultaneous assessment of arterial inflow, venous outflow, and CSF motion at high temporal resolution. Ultrafast EPI was acquired at the C2–C3 spinal level, enabling real-time imaging of CSF flow dynamics in the cervical spinal canal alongside arterial and venous blood flow in major cervical vessels (frame rate: 21.7 Hz). Furthermore, intrinsic arterial signal fluctuations were leveraged as a timing reference to reconstruct cardiac-resolved CSF dynamics for individual cardiac cycles without external physiological recordings. Frequency-domain analysis revealed distinct spectral signatures in CSF flow compared with neurovascular flow, including broadened cardiac peaks and enhanced respiratory modulation, particularly within the ventral spinal canal. In contrast, dorsal CSF showed increased power within the cardiac frequency band, higher coherence with cervical vasculature at the cardiac frequency, and reduced non-cardiac contributions. Time-domain analysis showed strong correlation between CSF flow waveforms derived from ultrafast EPI and PC-MRI. Beyond ensemble-averaged waveforms, ultrafast EPI enabled beat-to-beat analysis, revealing substantial cycle-to-cycle variability in CSF flow that is not captured by time-averaged gated approaches. Together, these findings establish ultrafast EPI as a rapid, complementary framework to PC-MRI, enabling real-time neurofluid imaging with integrated time- and frequency-domain characterization of CSF and neurovascular flow dynamics.
- Open Access
Moving Past Tonsil Position: Craniocervical Junction Crowding Shapes Cerebrospinal Fluid Effective Motility in Chiari I Malformation
Chiari I malformation (CM-I) is conventionally defined by cerebellar tonsil position, yet tonsil position is an indirect surrogate for the anatomic obstruction that impairs cerebrospinal fluid (CSF) flow across the craniocervical junction (CCJ). We hypothesized that CCJ crowding, quantified as subarachnoid space narrowing at the foramen magnum and C1, would explain CSF flow impairment more directly than tonsil position. Using non-invasive low b-value diffusion-weighted MRI (low-b dMRI), we quantified effective CSF motility, indexed by mean pseudo-diffusivity (MΨ), across the upper cervical spine, CCJ, and posterior fossa. Voxel-wise CCJ CSF pseudo-diffusion spatial statistics were integrated with CSF Waterways atlas-based regional analyses. We applied this approach in 81 pediatric and adult participants with CM-I to determine how CCJ structural features shape regional CSF dynamics and clinical outcomes. Voxel-wise analyses revealed that crowding at the foramen magnum was the dominant structural determinant of reduced intracranial CSF effective motility across the CCJ, basilar cisterns, and fourth ventricular outflow pathways (family-wise error corrected p < 0.05). While lower tonsil position and C1 level crowding were also associated with reduced CSF effective motility across the CCJ and fourth ventricular outflow pathways, but their associations within the basilar cisterns were spatially restricted to regions adjacent to the Liliequist membrane. Atlas-based region-of-interest analyses confirmed that greater foramen magnum crowding was associated with lower MΨ across multiple basilar cisterns, but with higher MΨ in the ventral spinal CSF compartment. Mediation analyses indicated that CCJ crowding at the foramen magnum and C1 accounted for the majority of the relationship between tonsil position and reduced CSF motility in the basilar cisterns. Multivariate MΨ profiles across the CSF regions identified data-driven foramen magnum crowding thresholds of 69.5% and 77.5%, stratifying patients into mild, moderate, and severe physiological crowding groups. Exploratory analyses linked lower pre-operative CSF MΨ to greater pain-related functional impairment, reduced cognitive function, and a higher likelihood of subsequent decompression surgery. Together, these findings demonstrate that CCJ crowding, particularly at the foramen magnum, exerts a quantifiable, region-specific impact on CSF effective motility in CM-I, and that low-b dMRI provides a sensitive, complementary marker of CSF flow impairment. This integrative CCJ structural and CSF flow imaging framework establishes a mechanistic link between CCJ anatomy, CSF dynamics, and symptom burden, offering a scalable tool for phenotyping CM-I and informing clinical decision-making.
Open AccessMoving Past Tonsil Position: Craniocervical Junction Crowding Shapes Cerebrospinal Fluid Effective Motility in Chiari I Malformation
Chiari I malformation (CM-I) is conventionally defined by cerebellar tonsil position, yet tonsil position is an indirect surrogate for the anatomic obstruction that impairs cerebrospinal fluid (CSF) flow across the craniocervical junction (CCJ). We hypothesized that CCJ crowding, quantified as subarachnoid space narrowing at the foramen magnum and C1, would explain CSF flow impairment more directly than tonsil position. Using non-invasive low b-value diffusion-weighted MRI (low-b dMRI), we quantified effective CSF motility, indexed by mean pseudo-diffusivity (MΨ), across the upper cervical spine, CCJ, and posterior fossa. Voxel-wise CCJ CSF pseudo-diffusion spatial statistics were integrated with CSF Waterways atlas-based regional analyses. We applied this approach in 81 pediatric and adult participants with CM-I to determine how CCJ structural features shape regional CSF dynamics and clinical outcomes. Voxel-wise analyses revealed that crowding at the foramen magnum was the dominant structural determinant of reduced intracranial CSF effective motility across the CCJ, basilar cisterns, and fourth ventricular outflow pathways (family-wise error corrected p < 0.05). While lower tonsil position and C1 level crowding were also associated with reduced CSF effective motility across the CCJ and fourth ventricular outflow pathways, but their associations within the basilar cisterns were spatially restricted to regions adjacent to the Liliequist membrane. Atlas-based region-of-interest analyses confirmed that greater foramen magnum crowding was associated with lower MΨ across multiple basilar cisterns, but with higher MΨ in the ventral spinal CSF compartment. Mediation analyses indicated that CCJ crowding at the foramen magnum and C1 accounted for the majority of the relationship between tonsil position and reduced CSF motility in the basilar cisterns. Multivariate MΨ profiles across the CSF regions identified data-driven foramen magnum crowding thresholds of 69.5% and 77.5%, stratifying patients into mild, moderate, and severe physiological crowding groups. Exploratory analyses linked lower pre-operative CSF MΨ to greater pain-related functional impairment, reduced cognitive function, and a higher likelihood of subsequent decompression surgery. Together, these findings demonstrate that CCJ crowding, particularly at the foramen magnum, exerts a quantifiable, region-specific impact on CSF effective motility in CM-I, and that low-b dMRI provides a sensitive, complementary marker of CSF flow impairment. This integrative CCJ structural and CSF flow imaging framework establishes a mechanistic link between CCJ anatomy, CSF dynamics, and symptom burden, offering a scalable tool for phenotyping CM-I and informing clinical decision-making.