Simultaneous real-time imaging of upper cervical cerebrospinal fluid and vascular dynamics using ultrafast inflow-weighted EPI
Open Access
- 22 September 2026
- journal article
- Published by MIT Press in Imaging Neuroscience
- Vol. 4
Abstract
Cerebrospinal fluid (CSF) circulation is tightly coupled to cerebral blood flow under the fixed-volume constraint of the cranial vault, with cardiac pulsations and respiration acting as dominant physiological drivers. Disruption of these flow dynamics has been implicated in various neurological disorders, motivating the need for imaging methods that capture CSF and vascular flow simultaneously and in real time. Conventional phase contrast MRI (PC-MRI) provides quantitative CSF velocity measurements but relies on cardiac gating and velocity encoding, which limit temporal resolution, dynamic range, and sensitivity to non-cardiac fluctuations. Here, we implement a single-slice ultrafast inflow-weighted echo-planar imaging (EPI), in which signal intensity reflects the replacement of saturated spins by freshly inflowing, unsaturated water molecules, yielding higher signal with higher flow velocity. This allows simultaneous assessment of arterial inflow, venous outflow, and CSF motion at high temporal resolution. Ultrafast EPI was acquired at the C2–C3 spinal level, enabling real-time imaging of CSF flow dynamics in the cervical spinal canal alongside arterial and venous blood flow in major cervical vessels (frame rate: 21.7 Hz). Furthermore, intrinsic arterial signal fluctuations were leveraged as a timing reference to reconstruct cardiac-resolved CSF dynamics for individual cardiac cycles without external physiological recordings. Frequency-domain analysis revealed distinct spectral signatures in CSF flow compared with neurovascular flow, including broadened cardiac peaks and enhanced respiratory modulation, particularly within the ventral spinal canal. In contrast, dorsal CSF showed increased power within the cardiac frequency band, higher coherence with cervical vasculature at the cardiac frequency, and reduced non-cardiac contributions. Time-domain analysis showed strong correlation between CSF flow waveforms derived from ultrafast EPI and PC-MRI. Beyond ensemble-averaged waveforms, ultrafast EPI enabled beat-to-beat analysis, revealing substantial cycle-to-cycle variability in CSF flow that is not captured by time-averaged gated approaches. Together, these findings establish ultrafast EPI as a rapid, complementary framework to PC-MRI, enabling real-time neurofluid imaging with integrated time- and frequency-domain characterization of CSF and neurovascular flow dynamics.Keywords
This publication has 56 references indexed in Scilit:
- Real‐time quantification of in vivo cerebrospinal fluid velocity using the functional magnetic resonance imaging inflow effectNMR in Biomedicine, 2024
- Spectral analysis of physiological brain pulsations affecting the BOLD signalHuman Brain Mapping, 2021
- Phase contrast MRI measurements of net cerebrospinal fluid flow through the cerebral aqueduct are confounded by respirationJournal of Magnetic Resonance Imaging, 2018
- Quantifying the influence of respiration and cardiac pulsations on cerebrospinal fluid dynamics using real‐time phase‐contrast MRIJournal of Magnetic Resonance Imaging, 2017
- Simultaneous multislice (SMS) imaging techniquesMagnetic Resonance in Medicine, 2015
- Effect of respiration on the B0 field in the human spinal cord at 3TMagnetic Resonance in Medicine, 2014
- Shared velocity encoding: A method to improve the temporal resolution of phase‐contrast velocity measurementsMagnetic Resonance in Medicine, 2011
- Blipped‐controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g‐factor penaltyMagnetic Resonance in Medicine, 2011
- Real‐time MRI at a resolution of 20 msNMR in Biomedicine, 2010
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999