WYWentao Yang

Wentao Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Wentao Yang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Impedance Reshaping Control for Stability Enhancement of Grid-Following Inverters in Weak Grids

    by Bogu Huang, Yibo Wang, Yuhan Guo, Wentao Yang, Yuxuan Wu, Yanxin Hu

    Although the weak-grid stability of grid-following inverters has been widely studied, traditional SCR-based assessment mainly describes grid strength and does not directly quantify the minimum SCR required for stable operation under a specified active-power command. This paper uses a critical-SCR-oriented operating-boundary evaluation to compare the control-dependent dynamic stability requirement with the physical steady-state feasibility limit. It proposes a channel-specific impedance-reshaping extension that retains the PLL-related q-q and d-q compensation paths and adds a voltage-loop-related q-d compensation path. The added path reduces the control-induced dynamic critical SCR, thereby allowing stable operation at lower SCR than with the original control structure. Firstly, the steady-state critical SCR is derived from the steady-state power-transfer relation under a specified active-power command to define the physical feasibility lower bound, and the dynamic critical SCR is identified using a scanning procedure based on the generalized Nyquist criterion. The resulting control-induced SCR gap quantifies the additional grid-strength requirement introduced by the control dynamics. Secondly, a simplified d-q admittance representation is used to relate established PLL-related and voltage-loop-related coupling effects to the corresponding compensation paths. Thirdly, the proposed channel-specific impedance-reshaping design is used to mitigate these effects while retaining the selected voltage-loop bandwidth, and an anti-drift correction is further introduced to improve implementation robustness. Frequency-domain analysis and time-domain simulations validate the dynamic critical-SCR evaluation, while hardware-in-the-loop experiments demonstrate the real-time operation of the proposed controller. The results show that it moves the dynamic critical-SCR boundary close to the steady-state physical boundary and improves the weak-grid stability margin. The hardware-in-the-loop results further confirm bounded operation under SCR and frequency steps.


  • Open Access

    A Unified VSG–VAM Energy Function for Stability Assessment of Coupled Electric–Thermal Microgrids

    by Wentao Yang, Yibo Wang, Bogu Huang, Yuhan Guo, Yuxuan Wu

    This paper develops a measurable unified electric–thermal energy indicator for converter-dominated microgrids, containing virtual synchronous generator (VSG) and virtual asynchronous machine (VAM) dynamics. The principal contribution comprises the scalar energy indicator HΣ and its normalized margin ηstab; together, they combine active-power–frequency, reactive-power–voltage, thermal-flow, current-boundary, and electric–thermal coupling information obtained from point-of-common-coupling measurements and thermal states. A bounded event-triggered thermal–electric action is used only as a secondary demonstration of how the indicator can support current-constrained coordination; it is not proposed as a replacement for the inner VSG controller. Local positive-definiteness, dissipation, invariant-sublevel-set, and two-time-scale conditions are derived in an explicitly defined operating domain. The framework was evaluated in a three-phase Simulink/Simscape model using a 26-run matrix of disturbance and parameter cases, together with three severe-case baselines and four reduced-order channel-isolation cases. For voltage-sag depths of 5–20%, the event increase in HΣ/Hcrit rose from 0.137 to 0.385. In the severe 20% combined case, bounded coordination increased the minimum margin from 0.048 to 0.138, with 0.0897 kWh of heat-load reduction; however, its trajectory was identical to that of the matched current-threshold trigger, so no controller-performance superiority is claimed. Omitting Hqv, Hth, Hlim and Hcpl eliminated 100.0%, 99.7%, 90.8% and 87.3%, respectively, of the corresponding event-window sensitivity. Under deep-current saturation, the limiter gain fell to 0.466 and ηstab reached zero, numerically identifying a boundary beyond which the local stability guarantee must not be extrapolated.

  • Open Access

    Energy-Auditable Distributed Virtual Asynchronous Machine Control for Thermal-Energy-Storage-Based Virtual Energy Storage Systems

    by Wentao Yang, Yibo Wang, Yuhan Guo, Runze Zhang

    Converter-dominated power systems increasingly require flexible resources that can support frequency while preserving a physically interpretable energy trajectory. Thermal-energy-storage (TES)-based virtual energy storage systems (VESSs) can shift electrical demand within thermal-energy and comfort constraints, and have therefore attracted extensive interest. However, existing studies commonly coordinate requested or normalized power without fully connecting it to actuator execution and the electrical-to-thermal energy path. Command-level sharing cannot be directly equated with executed physical power, and controller storage cannot be combined with joule-valued hardware energy without dimensional separation. Therefore, this paper proposes a physically coupled and energy-traceable virtual asynchronous machine (VAM) control method for TES-based VESSs. First, a loss-resolved averaged model establishes the point-of-common-coupling (PCC)–converter–DC-link–actuator–TES physical chain and separates the hardware Hamiltonian from the dimensionless control Lyapunov function. Second, a neighbor-coupled marginal controller is embedded in a command–projection–execution chain so that frequency regulation and weighted sharing are evaluated using the executed service. Third, a constraint-handling mechanism combines directional headroom gating, actuator saturation and ramp limits, thermal comfort bounds, and request-inactive state reset to maintain executable trajectories under the declared constraints. Simulations under a sustained 120kW disturbance show that primary-only control retains a −0.08883Hz steady-state offset, whereas the proposed nominal case restores frequency. In the constrained case, the 30 s terminal trend remains above the prescribed limit, while both terminal windows of the 60 s run satisfy the restoration criterion; the final-window mean error and dimensionless eligible-unit sharing spread are −6.317×10−5Hz and 6.564×10−5, respectively. The model-internal electrical–thermal balance achieves a dimensionless relative RMS residual of 6.2361×10−8. Because the PCC voltage/current pair is reconstructed from the same power source, this residual quantifies model-internal consistency rather than independent measured closure. These results demonstrate constrained frequency restoration, executed-power coordination, and energy traceability within the averaged-model scope.