Kehan Qiu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kehan Qiu has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Qiaojue Liu
Nanjing University of Aeronautics and Astronautics
2 shared publications - Shuqun Wu
Nanjing University of Aeronautics and Astronautics
2 shared publications - Miao Lyu
Nanjing University of Aeronautics and Astronautics
1 shared publication Xinyu Tao
Nanjing University of Aeronautics and Astronautics
1 shared publicationYangyang Chen
State Grid Electric Power Research Institute, NARI Group Corporation
1 shared publication- Zheng Qiu
Nanjing University of Aeronautics and Astronautics
1 shared publication
Latest Publications
- 22 October 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (42) , 425204
Design and implementation of a flexible high-voltage pulsed power supply for wearable applications
Kilovolt-level flexible wearable electronic systems are in critical demand for advanced applications spanning healthcare, human-machine interaction, and soft robotics. This paper proposes a flexible high-voltage pulsed power supply based on a multi-stage collaborative step-up architecture. Constructed on the flexible substrate, the power supply integrates a front-end DC Boost converter, a solid-state half-bridge pulse modulator, and an input-parallel output-series micro-transformer network. It employs a non-uniform layout strategy that combines the localized concentration of rigid components with serpentine routing to buffer mechanical deformation. Furthermore, multiphysics finite element models encompassing electric, thermal, and solid mechanics fields were established to systematically validate the design rationale. Experimental evaluations demonstrate that the developed prototype delivers microsecond pulses with a peak voltage amplitude of up to 4.5 kV and a rise time of 250 ns. The highly compact prototype features a total footprint of 13.92 cm 2 and a weight of 5.1 g, while sustaining macroscopic bending angles of up to 120°. Notably, the prototype successfully drives a cold plasma load with an active area of 20 cm 2 . This work validates the novel concept of a flexible kilovolt-level pulsed power supply, overcoming the inherent voltage bottlenecks of wearable electronics and providing a critical hardware foundation for frontier applications such as chronic wound healing, deep neuromodulation, and soft robotics. These results demonstrate the feasibility of a flexible kilovolt-level pulsed power platform and provide an implementation pathway for future flexible systems requiring localized high-electric-field excitation.
- 22 October 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (42) , 425204
Design and implementation of a flexible high-voltage pulsed power supply for wearable applications
Kilovolt-level flexible wearable electronic systems are in critical demand for advanced applications spanning healthcare, human-machine interaction, and soft robotics. This paper proposes a flexible high-voltage pulsed power supply based on a multi-stage collaborative step-up architecture. Constructed on the flexible substrate, the power supply integrates a front-end DC Boost converter, a solid-state half-bridge pulse modulator, and an input-parallel output-series micro-transformer network. It employs a non-uniform layout strategy that combines the localized concentration of rigid components with serpentine routing to buffer mechanical deformation. Furthermore, multiphysics finite element models encompassing electric, thermal, and solid mechanics fields were established to systematically validate the design rationale. Experimental evaluations demonstrate that the developed prototype delivers microsecond pulses with a peak voltage amplitude of up to 4.5 kV and a rise time of 250 ns. The highly compact prototype features a total footprint of 13.92 cm 2 and a weight of 5.1 g, while sustaining macroscopic bending angles of up to 120°. Notably, the prototype successfully drives a cold plasma load with an active area of 20 cm 2 . This work validates the novel concept of a flexible kilovolt-level pulsed power supply, overcoming the inherent voltage bottlenecks of wearable electronics and providing a critical hardware foundation for frontier applications such as chronic wound healing, deep neuromodulation, and soft robotics. These results demonstrate the feasibility of a flexible kilovolt-level pulsed power platform and provide an implementation pathway for future flexible systems requiring localized high-electric-field excitation.
- 18 August 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (33) , 335202
Closed-loop regulation of surface temperature for suppressing thermal drift in dielectric barrier discharge
Flexible dielectric barrier discharge (FDBD) devices are promising plasma sources for thermally sensitive plasma-treatment scenarios and potential biomedical applications for their flexibility and conformal adaptability. However, continuous discharge can cause surface heat accumulation, which may further contribute to thermally induced discharge-state drift. In this study, a feedback closed-loop surface-temperature regulation method is developed for an FDBD device. An infrared sensor is used to monitor the two-dimensional temperature field, and the average surface temperature in the discharge region is selected as the controlled target. Open-loop experiments at different driving frequencies are used to identify a first-order thermal model, with the pulse frequency serving as the manipulated variable for regulating the energy input. Based on this model, PI and BP-PID controllers are implemented as two closed-loop control strategies on an STM32 embedded platform. The closed-loop experiments show that the average surface temperature tracks the selected setpoints of 34, 37, and 40 °C, with the BP-PID implementation providing improved tracking and disturbance-rejection behavior relative to the PI baseline. Optical-emission analysis further shows that the spectral intensity ratio I 391.4 / I 337.1 , used here as an E/N -sensitive optical proxy for relative variations in the excitation conditions, exhibits a positive long-term drift under open-loop operation. This drift is weakened under active temperature control, indicating that closed-loop thermal regulation can reduce the long-term variation of the E/N -sensitive optical proxy during continuous FDBD operation. The results provide an experimental basis for the active thermal regulation of FDBD systems to achieve stable, repeatable operation in thermally sensitive plasma applications.
- 18 August 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (33) , 335202
Closed-loop regulation of surface temperature for suppressing thermal drift in dielectric barrier discharge
Flexible dielectric barrier discharge (FDBD) devices are promising plasma sources for thermally sensitive plasma-treatment scenarios and potential biomedical applications for their flexibility and conformal adaptability. However, continuous discharge can cause surface heat accumulation, which may further contribute to thermally induced discharge-state drift. In this study, a feedback closed-loop surface-temperature regulation method is developed for an FDBD device. An infrared sensor is used to monitor the two-dimensional temperature field, and the average surface temperature in the discharge region is selected as the controlled target. Open-loop experiments at different driving frequencies are used to identify a first-order thermal model, with the pulse frequency serving as the manipulated variable for regulating the energy input. Based on this model, PI and BP-PID controllers are implemented as two closed-loop control strategies on an STM32 embedded platform. The closed-loop experiments show that the average surface temperature tracks the selected setpoints of 34, 37, and 40 °C, with the BP-PID implementation providing improved tracking and disturbance-rejection behavior relative to the PI baseline. Optical-emission analysis further shows that the spectral intensity ratio I 391.4 / I 337.1 , used here as an E/N -sensitive optical proxy for relative variations in the excitation conditions, exhibits a positive long-term drift under open-loop operation. This drift is weakened under active temperature control, indicating that closed-loop thermal regulation can reduce the long-term variation of the E/N -sensitive optical proxy during continuous FDBD operation. The results provide an experimental basis for the active thermal regulation of FDBD systems to achieve stable, repeatable operation in thermally sensitive plasma applications.