AYAhmet Can Yalcin

Ahmet Can Yalcin

*This is an algorithmically generated author record based on publicly available information.

Ahmet Can Yalcin has a total of 3 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Effect of Conductor Geometry on Electric Field Distribution in Air-Insulated Medium Voltage Busbar Systems

    by Ahmet Can Yalcin, Huseyin Akdemir, Cihat Cagdas Uydur, Bekir Dursun

    In the design processes of medium-voltage (MV) systems, ensuring insulation safety is considered a critical parameter in terms of both system sustainability and the service life of the components used. In this study, the direct effects of the cross-sectional geometry of conductors used in air-insulated switchgear (AIS) systems on electric field distribution and dielectric strength characteristics were quantitatively investigated through numerical analysis methods. Within the scope of the research, conductor models with different geometric structures were created based on a rated line-to-line voltage level of 17.5 kV, and these models were analyzed using the finite element method with COMSOL Multiphysics® (AC/DC Module 6.2 version) software under the rated peak inter-phase potential difference (24.75 kV). Simulation studies demonstrate that curved transitions at the rounded edges on conductor surfaces cause electric field lines to concentrate at these boundaries, leading to local electric field intensification. In calculations performed on a standard rectangular cross-section conductor with dimensions CU-6 × 180 mm, the maximum electric field strength reached 10.90 kV/cm at the rounded edges. For wider rectangular profiles such as CU-12 × 220 mm and CU-12 × 360 mm, maximum field strengths remained at 7.77 kV/cm and 7.42 kV/cm, respectively. In contrast, adopting equal-area cylindrical configurations for these profiles reduced the peak electric field to 4.54 kV/cm (for the 12 × 220 mm equivalent) and 4.22 kV/cm (for the 12 × 360 mm equivalent) owing to the uniform charge distribution across the continuous cylindrical boundary. Beyond the qualitative understanding of electrostatic curvature, this study quantitatively benchmarks the dielectric safety margins and field utilization factors for standardized industrial MV busbar profiles at 17.5 kV, providing practical geometric criteria for partial discharge mitigation in compact switchgear designs. The findings indicate that profile geometry serves as an effective design measure in mitigating electrical stress and reducing partial discharge risk in medium-voltage equipment.

  • Open Access

    Multi-Physics (Electromagnetic–Thermal–CFD) and Techno-Economic Analysis of Double-Neutral and Increased Cross-Section Scenarios in Harmonically Loaded Busbar Trunking Systems

    by Huseyin Akdemir, Ahmet Can Yalcin, Bekir Dursun, Cihat Cagdas Uydur

    In this study, the double-neutral (3P + 2N) configuration, considered a traditional solution for busbar systems subjected to overcurrent and thermal stresses under harmonic loads, and alternative cross-sectional expansion (from 6 mm × 55 mm to 6 mm × 65 mm) scenarios are investigated using a multidisciplinary approach. In this context, the electrical, electromagnetic, current density distributions, and magnetic flux densities (Bmax) of the systems are modeled in the COMSOL Multiphysics® (AC/DC Module 6.2 version) environment; the obtained q″ (W/m3) loss maps were transferred to FLOEFD convective airflow (CFD) simulations as volumetric heat sources, and steady-state electro-thermal analyses were performed. Convergence tests were conducted with the BiCGStab solver to ensure numerical stability, solver convergence, and spatial grid independence, and high accuracy was obtained at a margin of error of 3.5222 × 10−4. The findings showed that the proximity effect, due to the close placement of the pair of neutral conductors at the 150 Hz harmonic frequency, increased the current density to 4.68 A/mm2 and turned the neutral line into an additional heat source. In contrast, in the 4-conductor scheme where all conductor cross-sections were increased by 18.18%, the magnetic flux density at 150 Hz was suppressed from 27.21 mT to 23.50 mT, and the current density was distributed more homogeneously, optimizing the temperature rise limits (ΔT). Furthermore, the techno-economic cost analysis conducted revealed that, under premium scenarios for LME raw copper and processed bar copper, the application of increased cross-sectional area offered an optimization that was approximately 5.77% more economical per meter (approximately $36 USD for a standard 3 m length) compared to the double-neutral configuration. Consequently, it has been proven that in BTS designs, not only total harmonic distortion (THD) but also the triplen harmonic ratio, frequency-dependent AC resistance (Rac) variations, and material mass–cost balance should be considered together.

  • Open Access

    Analysis of Geometry-Dependent Skin Effect in High-Current Conductors: A Comparative Study of Busbar and Cable Geometries

    by Cihat Cagdas Uydur, Huseyin Akdemir, Ahmet Can Yalcin, Bekir Dursun

    Given the modernization of power systems in recent years, the quality of electrical energy is changing. With the increasing prevalence of harmonic components and rising current densities, conductor efficiency has become critically important. This study investigates the skin effect as a function of conductor geometry within the framework of electromagnetic field theory. Classical circular cross-section cable geometries and rectangular busbar systems were compared under an AC current of 1350 A (peak) across a frequency range of 50–500 Hz. The findings are comparatively presented, and their electromagnetic and thermal implications are discussed. Numerical modeling and simulation studies were performed using the Finite Element Method. COMSOL Multiphysics® software AC/DC Module 6.2 version was used for the analyses. In the simulation studies, the magnetic flux density distribution within the conductor and the current concentration induced by eddy currents were analyzed. Frequency-dependent behavioral characteristics were examined in the analyses. The results revealed that the conductor with circular geometry exhibited a more severe skin effect. The rectangular conductor used in busbar systems was found to effectively distribute the current density across its surface area. Thus, rectangular geometry optimizes AC resistance. The analysis results revealed that conductor design and material selection depend not only on the cross-sectional area but also on the geometric shape factor. In this context, it was determined that conductor design has a decisive effect on electromagnetic power losses, which directly govern the heat generation potential within high-current systems. This study serves as a technical guide to evaluate frequency-dependent electromagnetic performance across a 50–500 Hz range—reflecting frequencies relevant to harmonic components—to assist in the design and optimization of high-current energy distribution systems.