Marek Smid
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marek Smid has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Aarre Kilpeläinen
Aalto University, Metrology Research Institute
1 shared publication - Alejandro Ferrero
Consejo Superior de Investigaciones Científicas
1 shared publication Constantinos Bouroussis
Metas
1 shared publication- Erkki Ikonen
Metrology Research Institute, Aalto University, 02150 Espoo, Finland
1 shared publication - Farshid Manoocheri
Metrology Research Institute, Aalto University, Espoo, Finland
1 shared publication - Geiland Porrovecchio
Czech Metrology Institute
1 shared publication
Latest Publications
- Open Access
- 11 November 2026
- Published by IOP Publishing in Metrologia
Luminance measurement model for high-dynamic-range imaging systems
The measurements of high-contrast scenes, where there are very different levels of luminance simultaneously, is necessary for a growing number of applications in lighting. For evaluating this kind of scene, high-dynamic-range (HDR) measurements with imaging systems are required. A methodology must be established and verified to provide traceable HDR luminance measurements. A measurement model for these measurements is proposed and described, which allows traceability of HDR luminance measurements with imaging systems. This model includes the variables that need to be considered to properly evaluate the uncertainty of the measurement. The uncertainty is derived analytically from the measurement model for luminance measured at individual pixels, and the propagation of this uncertainty is considered when the average luminance across several pixels needs to be measured, including the correlations of the errors at different pixels and luminous sources in the scene. This analytical approach to the evaluation of uncertainty is important for understanding the impact of the different sources of uncertainties. The Monte Carlo approach, which is simpler and easier to implement, is also presented and discussed.
- 11 November 2026
- Published by IOP Publishing in Metrologia
Open AccessLuminance measurement model for high-dynamic-range imaging systems
The measurements of high-contrast scenes, where there are very different levels of luminance simultaneously, is necessary for a growing number of applications in lighting. For evaluating this kind of scene, high-dynamic-range (HDR) measurements with imaging systems are required. A methodology must be established and verified to provide traceable HDR luminance measurements. A measurement model for these measurements is proposed and described, which allows traceability of HDR luminance measurements with imaging systems. This model includes the variables that need to be considered to properly evaluate the uncertainty of the measurement. The uncertainty is derived analytically from the measurement model for luminance measured at individual pixels, and the propagation of this uncertainty is considered when the average luminance across several pixels needs to be measured, including the correlations of the errors at different pixels and luminous sources in the scene. This analytical approach to the evaluation of uncertainty is important for understanding the impact of the different sources of uncertainties. The Monte Carlo approach, which is simpler and easier to implement, is also presented and discussed.
- Open Access
- 1 October 2026
- Published by IOP Publishing in Metrologia
- Vol. 63 (5) , 055010
Quantum yield of silicon in the spectral range from ultraviolet to visible
The essential steps for simulating the quantum yield of silicon have been thoroughly studied in the wavelength range from ultraviolet to visible. We have separately estimated excess quantum yield contributions arising from primary carriers created after photon absorption using the Quantum Espresso software. This is acheived by calculating the distribution functions of charge carriers over the available energy range and the probabilities of charge carriers generating secondary carriers. The resulting quantum yield values are compared to those obtained using high-accuracy measurement data from different types of silicon-based predictable quantum efficient detectors (PQEDs), indicating better than ±2.5% relative agreement within the spectral interval 200 nm—480 nm.
- 1 October 2026
- Published by IOP Publishing in Metrologia
- Vol. 63 (5) , 055010
Open AccessQuantum yield of silicon in the spectral range from ultraviolet to visible
The essential steps for simulating the quantum yield of silicon have been thoroughly studied in the wavelength range from ultraviolet to visible. We have separately estimated excess quantum yield contributions arising from primary carriers created after photon absorption using the Quantum Espresso software. This is acheived by calculating the distribution functions of charge carriers over the available energy range and the probabilities of charge carriers generating secondary carriers. The resulting quantum yield values are compared to those obtained using high-accuracy measurement data from different types of silicon-based predictable quantum efficient detectors (PQEDs), indicating better than ±2.5% relative agreement within the spectral interval 200 nm—480 nm.
- Open Access
- 8 September 2026
- Published by IOP Publishing in Metrologia
- Vol. 63 (5) , 055003
Optical fibre power metre calibration against cryogenic radiometers at telecom wavelengths
A study of optical fibre power metre calibrations is presented based on comparison with fibre-coupled cryogenic radiometry. Three nearly identical cryogenic radiometers are used together with a free-space absolute spectral responsivity measurement facility. The results show that the dominant sources of uncertainty originate not from the radiometers or the transfer standard detector, but from the optical path components used to convey light from the source to the detector. The properties of the optical radiation, defined by wavelength, polarization, and modal quality, together with system components such as optical fibres, fibre switches, fibre splitters, polarization controllers, and external influences including temperature and vibration, limit the achievable uncertainty. Measurements are performed at optical power levels near 100 µW, a regime in which the underlying measurement technology has matured over several decades. The absolute uncertainty ranges from approximately 0.0010 A W −1 to 0.0043 A W −1 , depending on the wavelength and components. The results provide a quantitative basis for assessing the limits of uncertainty reduction in fibre-based optical power measurements and are relevant to future uncertainty analyses of fibre-coupled single-photon detector efficiency in quantum communications and quantum technologies in general.
- 8 September 2026
- Published by IOP Publishing in Metrologia
- Vol. 63 (5) , 055003
Open AccessOptical fibre power metre calibration against cryogenic radiometers at telecom wavelengths
A study of optical fibre power metre calibrations is presented based on comparison with fibre-coupled cryogenic radiometry. Three nearly identical cryogenic radiometers are used together with a free-space absolute spectral responsivity measurement facility. The results show that the dominant sources of uncertainty originate not from the radiometers or the transfer standard detector, but from the optical path components used to convey light from the source to the detector. The properties of the optical radiation, defined by wavelength, polarization, and modal quality, together with system components such as optical fibres, fibre switches, fibre splitters, polarization controllers, and external influences including temperature and vibration, limit the achievable uncertainty. Measurements are performed at optical power levels near 100 µW, a regime in which the underlying measurement technology has matured over several decades. The absolute uncertainty ranges from approximately 0.0010 A W −1 to 0.0043 A W −1 , depending on the wavelength and components. The results provide a quantitative basis for assessing the limits of uncertainty reduction in fibre-based optical power measurements and are relevant to future uncertainty analyses of fibre-coupled single-photon detector efficiency in quantum communications and quantum technologies in general.