BLBolin Li

Bolin Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bolin Li has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Laser Doppler Gas Flowmeter with Synchronous Three-Point Measurement

    by Jian Zhou, Bolin Li, Shuang Zhang, Xiaoming Nie

    To address the challenges of susceptibility to interference and limited accuracy inherent in conventional gas flow rate measurement methods, this paper proposes and investigates a laser Doppler gas flow rate measurement method based on synchronous three-point velocity measurement. This method simultaneously measures the flow velocities at three characteristic points within the pipeline cross-section, subsequently fits and reconstructs the velocity distribution across the entire profile, and ultimately achieves high-precision flow measurement. The feasibility of selecting the center point, the quarter-width point, and the near-wall point as the three characteristic measurement positions is analyzed through computational fluid dynamics simulations, and the full-profile velocity distribution is fitted accordingly. A three-point synchronous velocity-flow rate measurement system is designed and constructed, employing a transmitting optical path based on the “three beam splitters and two mirrors” scheme and a receiving optical path based on the “multi-lens independent reception” scheme, and experimental validation is conducted. Experimental results demonstrate that the system operates stably with good repeatability. In contrast to the flow calculation method using a single-point Pitot tube combined with an empirical formula, the proposed system, which directly fits the velocity profile and integrates it for flow calculation, effectively avoids the significant model errors caused by using fixed empirical coefficients in non-circular pipe flows, and is inherently more universally applicable in principle. Through comparison with the TSI reference standard (3D LDV), the measurement results of the proposed system are in close agreement with the reference values, with relative errors all below −0.8%. This paper provides an effective solution for high-precision gas flow measurement in square pipelines.

  • Open Access

    Investigation of a Dual-Wavelength Solid-State Laser Self-Mixing Vibration Measurement Method

    by Jian Zhou, Bolin Li, Yicong Feng, Qi Wang, Xiaoming Nie

    To address the contradiction between high resolution and structural complexity in traditional laser self-mixing measurement systems, the co-axial dual-wavelength solid-state laser self-mixing technology was proposed and studied. An LD pumped the Nd:YVO4 crystal and doubled the frequency to generate two wavelengths laser at 1064 nm and 532 nm, and a co-axial dual-wavelength laser self-mixing measurement system was constructed. A 90° phase difference between the two wavelengths was produced by adjusting the angle of incidence of the parallel glass plate. As a result, a set of orthogonal signals was built to distinguish the direction of the displacement for the target. The experiments showed that the measuring system can adapt to different vibration waveforms and that the frequency measurement upper limit can be reached at 7 kHz. The system exhibited high precision in displacement measurement, with an RMS displacement noise of 8.64 nm and a cumulative error of 33.66 nm at a peak-to-peak amplitude of 5000 nm, along with a short-term resolution better than 2 nm.