XNXiaoming Nie

Xiaoming Nie

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiaoming Nie has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Laser Doppler Gas Flowmeter with Synchronous Three-Point Measurement

    by Jian Zhou, Bolin Li, Shuang Zhang, Xiaoming Nie

    To address the challenges of susceptibility to interference and limited accuracy inherent in conventional gas flow rate measurement methods, this paper proposes and investigates a laser Doppler gas flow rate measurement method based on synchronous three-point velocity measurement. This method simultaneously measures the flow velocities at three characteristic points within the pipeline cross-section, subsequently fits and reconstructs the velocity distribution across the entire profile, and ultimately achieves high-precision flow measurement. The feasibility of selecting the center point, the quarter-width point, and the near-wall point as the three characteristic measurement positions is analyzed through computational fluid dynamics simulations, and the full-profile velocity distribution is fitted accordingly. A three-point synchronous velocity-flow rate measurement system is designed and constructed, employing a transmitting optical path based on the “three beam splitters and two mirrors” scheme and a receiving optical path based on the “multi-lens independent reception” scheme, and experimental validation is conducted. Experimental results demonstrate that the system operates stably with good repeatability. In contrast to the flow calculation method using a single-point Pitot tube combined with an empirical formula, the proposed system, which directly fits the velocity profile and integrates it for flow calculation, effectively avoids the significant model errors caused by using fixed empirical coefficients in non-circular pipe flows, and is inherently more universally applicable in principle. Through comparison with the TSI reference standard (3D LDV), the measurement results of the proposed system are in close agreement with the reference values, with relative errors all below −0.8%. This paper provides an effective solution for high-precision gas flow measurement in square pipelines.

  • Open Access

    Investigation of a Dual-Wavelength Solid-State Laser Self-Mixing Vibration Measurement Method

    by Jian Zhou, Bolin Li, Yicong Feng, Qi Wang, Xiaoming Nie

    To address the contradiction between high resolution and structural complexity in traditional laser self-mixing measurement systems, the co-axial dual-wavelength solid-state laser self-mixing technology was proposed and studied. An LD pumped the Nd:YVO4 crystal and doubled the frequency to generate two wavelengths laser at 1064 nm and 532 nm, and a co-axial dual-wavelength laser self-mixing measurement system was constructed. A 90° phase difference between the two wavelengths was produced by adjusting the angle of incidence of the parallel glass plate. As a result, a set of orthogonal signals was built to distinguish the direction of the displacement for the target. The experiments showed that the measuring system can adapt to different vibration waveforms and that the frequency measurement upper limit can be reached at 7 kHz. The system exhibited high precision in displacement measurement, with an RMS displacement noise of 8.64 nm and a cumulative error of 33.66 nm at a peak-to-peak amplitude of 5000 nm, along with a short-term resolution better than 2 nm.


  • Transmittance characteristics of Gaussian beam passing through multi-circular-aperture chopper: modeling and simulation

    by Xiaoming Nie, Jian Zhou, Qi Wang

    Traditionally, the transmittance analysis of a beam passing through an optical chopper is based on the assumption of a top‑hat beam. However, most practical laser sources emit Gaussian beams. This paper establishes a complete theoretical model for the transmittance of a Gaussian beam passing through a multi‑circular‑aperture chopper, in which the luminous flux contributions of all apertures are considered simultaneously. An analytical transmittance expression is derived by using the Marcum Q function, which avoids cumbersome two‑dimensional numerical integration and improves computational efficiency significantly. Two dimensionless characteristic parameters dominating the transmittance behavior are identified: \(c_{1}=w/R\) (the ratio of the beam radius to the offset distance between the beam center and the chopper rotation center) and \(c_{2}=w/r_{a}\) (the ratio of the beam radius to the aperture radius). Based on the proposed model, the influences of the aperture number \(N\) and dimensionless parameters \(c_{1}\) and \(c_{2}\) on the period, waveform shape, and modulation depth of the transmittance curve are simulated and analyzed systematically. The results show that the modulation frequency increases linearly with \(N\), while \(c_{1}\) and \(c_{2}\) dominate the waveform smoothness and spectral distribution. This research provides accurate theoretical support for the structural design, parameter optimization, and engineering application of circular‑aperture choppers, and has important reference value for improving the modulation performance of optical systems.c2=w/ra(the ratio of beam radius to the aperture radius). Based on the proposed model, the influence of the aperture number $N$ and dimensionless parameters c1 and c2 on the period and shape of the transmittance curve was simulated and analyzed. The research results provide accurate theoretical support for the structural design, parameter optimization, and engineering application of circular-aperture choppers, and have important reference value for improving the modulation performance of optical systems.

  • Open Access

    Signal Processing Method and Evaluation Method for Weak Doppler Signal Detection

    by Chongbin Xi, Jian Zhou, Xiaoming Nie, Shilong Jin

    When the amplitude of the laser Doppler signal is less than that of the noise amplitude, the speed information cannot be identified. In this paper, the recognition of weak Doppler signals is accomplished by superimposing multiple-frame Doppler signals in the frequency domain and eliminating the base noise. Meanwhile, the relative prominence is defined to assess the quality of Doppler signals. The theoretical analysis and experimental results demonstrate that the relative prominence can be enhanced by more than two orders of magnitude through the stacking of 10,000 frames of Doppler signals. Moreover, this paper establishes a foundation for determining the threshold of relative prominence in practical measurements. When the relative prominence at a specific point on the spectrum is 3, there is at least a 99.08% probability that this point corresponds to the target signal.