SLSuyang Li

Suyang Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Suyang Li has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • Kuidong Gao

    College of Mechanical and Electronic Engineering, Shandong University of Science and Technology, Qingdao 266590, China

    1 shared publication
  • Lin Li

    College of Energy and Mining Engineering, Shandong University of Science and Technology 3 , Qingdao 266590

    1 shared publication
  • Liqing Sun

    College of Mechanical and Electronic Engineering, Shandong University of Science and Technology 1 , Qingdao 266590

    1 shared publication
  • Shenghao Ma

    College of Mechanical and Electronic Engineering, Shandong University of Science and Technology 1 , Qingdao 266590

    1 shared publication

Latest Publications

  • Study on the transient flow field evolution and mixing characteristics of a fluidic oscillator under ultrasonic excitation

    by Liqing Sun, Suyang Li, Shenghao Ma, Kuidong Gao, Lin Li

    To enhance reagent dispersion in high-viscosity systems, this study employs computational fluid dynamics simulations and high-speed photography to evaluate the transient flow and mixing characteristics of a fluidic oscillator mixer, comparing performance with and without ultrasonic excitation. The results indicated that ultrasonic intervention did not alter the inherent sweeping frequency but induced intensive alternating pressure pulsations. Quantitatively, over a 2.0 s period, the number of connected components (Ncc) exhibits a stepwise amplification with increasing ultrasonic intensity, confirming that high-frequency acoustic energy effectively shatters large-scale fluid structures to expand the mixing interfacial area. Concurrently, the introduction of ultrasound elevates the mean velocity but reduces the maximum velocity, revealing a stronger dependency on power over frequency, where higher power enhances internal momentum transport. Furthermore, the time-averaged volume-averaged turbulent kinetic energy and its corresponding dissipation rate under the ultrasonic condition are elevated by 45.6% and 10.2%, respectively. Quantitative image analysis confirmed that ultrasound significantly accelerates the initial mixing rate, reducing the concentration standard deviation at 0.23 s from 2.01 to 1.31. Throughout the subsequent evolution, ultrasound effectively suppresses localized concentration oscillations, steadily decreasing the final coefficient of variation of the flow field to approximately 0.14 to simultaneously enhance global mixing efficiency and homogeneity. This study offers useful fluid-dynamic insights for the design and optimization of ultrasound-assisted jet mixers.