Jiannan Tang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jiannan Tang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Weihao Wu
State Key Laboratory of Dark Matter Physics, Key Laboratory for Particle Astrophysics and Cosmology (MoE), Shanghai Key Laboratory for Particle Physics and Cosmology, School of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai 200240
2 shared publications - Yang Liu
State Key Laboratory of Dark Matter Physics, Key Laboratory for Particle Astrophysics and Cosmology (MoE), Shanghai Key Laboratory for Particle Physics and Cosmology, School of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai 200240
2 shared publications M. Wang
State Key Laboratory of Dark Matter Physics, Key Laboratory for Particle Astrophysics and Cosmology (MoE), Shanghai Key Laboratory for Particle Physics and Cosmology, School of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai 200240
1 shared publicationW. Zhi
State Key Laboratory of Dark Matter Physics, Key Laboratory for Particle Astrophysics and Cosmology (MoE), Shanghai Key Laboratory for Particle Physics and Cosmology, School of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai 200240
1 shared publicationWei Zhi
The State Key Laboratory of Dark Matter Physics, Key Laboratory for Particle Astrophysics and Cosmology (MoE), Shanghai Key Laboratory for Particle Physics and Cosmology, School of Physics and Astronomy, Shanghai Jiao Tong University , Shanghai 200240
1 shared publicationY. Guo
State Key Laboratory of Dark Matter Physics, Key Laboratory for Particle Astrophysics and Cosmology (MoE), Shanghai Key Laboratory for Particle Physics and Cosmology, School of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai 200240
1 shared publication
Latest Publications
- 1 October 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (10) , P10031
The high speed analog optical readout system designed for low temperature experiments
For low-temperature experiments such as liquid xenon dark matter detectors, it is crucial to read out detector signals from cryostats. Traditionally, photoelectrical signals are transmitted from the cryogenic region to the outside using coaxial cables through vacuum feedthroughs on the cryostats. In this paper, we investigate an analog optical transmission method in which the raw electrical signals are converted into optical signals with light intensity linearly proportional to the electrical amplitude, transmitted out of the cryogenic environment through optical fiber, and subsequently converted back into electrical signals by photoelectric devices while preserving the signal waveform. This new approach offers advantages, including low attenuation over long-distance transmission and reduced crosstalk across the feedthroughs. Additionally, the low-temperature optical wavelength multiplexing scheme has been investigated and applied, increasing the transmission capability of a single fiber. At -100 ∘ C, the proposed analog optical readout system achieves a -3 dB bandwidth of larger than 150 MHz, a dynamic range of up to 500 mV, and a low cryogenic-region power consumption of 70 mW per channel, demonstrating its strong potential for low-temperature experiments.
- 1 October 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (10) , P10031
The high speed analog optical readout system designed for low temperature experiments
For low-temperature experiments such as liquid xenon dark matter detectors, it is crucial to read out detector signals from cryostats. Traditionally, photoelectrical signals are transmitted from the cryogenic region to the outside using coaxial cables through vacuum feedthroughs on the cryostats. In this paper, we investigate an analog optical transmission method in which the raw electrical signals are converted into optical signals with light intensity linearly proportional to the electrical amplitude, transmitted out of the cryogenic environment through optical fiber, and subsequently converted back into electrical signals by photoelectric devices while preserving the signal waveform. This new approach offers advantages, including low attenuation over long-distance transmission and reduced crosstalk across the feedthroughs. Additionally, the low-temperature optical wavelength multiplexing scheme has been investigated and applied, increasing the transmission capability of a single fiber. At -100 ∘ C, the proposed analog optical readout system achieves a -3 dB bandwidth of larger than 150 MHz, a dynamic range of up to 500 mV, and a low cryogenic-region power consumption of 70 mW per channel, demonstrating its strong potential for low-temperature experiments.
- 1 August 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (8)
A cryogenic characterization platform for commercial off-the-shelf (COTS) electronic devices in liquid xenon detectors for high-energy physics experiments
The increasing deployment of cryogenic noble-liquid detectors in high-energy physics experiments has created a growing demand for reliable qualification methods for electronic components operating at temperatures beyond their specified ranges. However, the operating temperature range specified for commercial off-the-shelf electronic components typically does not extend to cryogenic temperatures, leaving their low-temperature characteristics insufficiently characterized and introducing uncertainties in detector electronics design. This study presents a versatile cryogenic characterization platform that enables systematic qualification of commercial electronic components under detector-relevant operating conditions. The platform provides a stable temperature environment centered at 165 K, corresponding to liquid xenon detector operation, while maintaining the relative humidity below 15% to minimize condensation-related failures. Furthermore, an FPGA-based digital electronics subsystem was developed to support device evaluation, with its key functional modules individually qualified to ensure reliable operation at 165 K before system-level integration. The platform was used to evaluate the performance of an ADI ADS52J65 analog-to-digital converter (ADC) and to characterize the cryogenic behavior of a Hamamatsu S13370 silicon photomultiplier (SiPM). Both devices operated reliably at 165 K. The ADC achieved a signal-to-noise ratio of ∼64 dB with a near-full-scale 1.1 MHz sinusoidal input, while the dark count rate of the SiPM was reduced to below 1 Hz. This study demonstrates a practical platform for the cryogenic characterization of front-end electronic devices intended for liquid xenon detectors. By combining a controlled cryogenic environment with a qualified digital electronics subsystem, the platform provides a reusable experimental infrastructure for evaluating commercial electronic components under cryogenic operating conditions and offers a practical solution for reducing uncertainties in the development of front-end electronics for liquid xenon detectors.
- 1 August 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (8)
A cryogenic characterization platform for commercial off-the-shelf (COTS) electronic devices in liquid xenon detectors for high-energy physics experiments
The increasing deployment of cryogenic noble-liquid detectors in high-energy physics experiments has created a growing demand for reliable qualification methods for electronic components operating at temperatures beyond their specified ranges. However, the operating temperature range specified for commercial off-the-shelf electronic components typically does not extend to cryogenic temperatures, leaving their low-temperature characteristics insufficiently characterized and introducing uncertainties in detector electronics design. This study presents a versatile cryogenic characterization platform that enables systematic qualification of commercial electronic components under detector-relevant operating conditions. The platform provides a stable temperature environment centered at 165 K, corresponding to liquid xenon detector operation, while maintaining the relative humidity below 15% to minimize condensation-related failures. Furthermore, an FPGA-based digital electronics subsystem was developed to support device evaluation, with its key functional modules individually qualified to ensure reliable operation at 165 K before system-level integration. The platform was used to evaluate the performance of an ADI ADS52J65 analog-to-digital converter (ADC) and to characterize the cryogenic behavior of a Hamamatsu S13370 silicon photomultiplier (SiPM). Both devices operated reliably at 165 K. The ADC achieved a signal-to-noise ratio of ∼64 dB with a near-full-scale 1.1 MHz sinusoidal input, while the dark count rate of the SiPM was reduced to below 1 Hz. This study demonstrates a practical platform for the cryogenic characterization of front-end electronic devices intended for liquid xenon detectors. By combining a controlled cryogenic environment with a qualified digital electronics subsystem, the platform provides a reusable experimental infrastructure for evaluating commercial electronic components under cryogenic operating conditions and offers a practical solution for reducing uncertainties in the development of front-end electronics for liquid xenon detectors.