Zheheng Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zheheng Xu has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Shun Tao
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources North China Electric Power University Beijing China
2 shared publications Shaobo Xu
Power Dispatch and Control Centre State Grid Shanxi Electric Power Co., Ltd Taiyuan China
1 shared publicationShuo Yang
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources North China Electric Power University Beijing China
1 shared publicationYonghai Xu
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources North China Electric Power University Beijing China
1 shared publication- Ziyu Wang
The State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources North China Electric Power University Beijing China
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 20 (1)
Voltage Source Converter Harmonic Model Considering Frequency Coupling Effects for Harmonic Load Flow Study
Voltage source converters (VSCs) are widely used in distribution grids. Their complex wideband harmonic responses, arising from frequency coupling (FC) effects, complicate harmonic load flow (HLF) analysis and are prone to amplification due to system resonance. To address these challenges, this paper develops an efficient and accurate frequency‐coupling admittance matrix (FCAM) harmonic model for a typical VSC. First, the FC phenomena caused by asymmetry in dq ‑axis control as well as by analogue/digital sampling and pulse width modulation sideband effects are analysed, and their combined influence on transfer paths of coupled harmonics is investigated. Then, the coupling spectrum is pre‐truncated based on physical mechanisms. This yields eight key coupled harmonic components and a compact FCAM model with a small matrix size and clear physical interpretability. Using this model, a non‑iterative multi‑frequency‑coupled HLF calculation method is proposed, improving the computational efficiency and stability. Finally, the accuracy of both the VSC harmonic model and HLF calculation method is validated through hardware‑in‑the‑loop simulations and electromagnetic transient simulations, respectively. Additionally, the model is applied to a modified IEEE 33‑bus test system for HLF study, and the frequency bands most sensitively affected by FC effects are identified.
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 20 (1)
Open AccessVoltage Source Converter Harmonic Model Considering Frequency Coupling Effects for Harmonic Load Flow Study
Voltage source converters (VSCs) are widely used in distribution grids. Their complex wideband harmonic responses, arising from frequency coupling (FC) effects, complicate harmonic load flow (HLF) analysis and are prone to amplification due to system resonance. To address these challenges, this paper develops an efficient and accurate frequency‐coupling admittance matrix (FCAM) harmonic model for a typical VSC. First, the FC phenomena caused by asymmetry in dq ‑axis control as well as by analogue/digital sampling and pulse width modulation sideband effects are analysed, and their combined influence on transfer paths of coupled harmonics is investigated. Then, the coupling spectrum is pre‐truncated based on physical mechanisms. This yields eight key coupled harmonic components and a compact FCAM model with a small matrix size and clear physical interpretability. Using this model, a non‑iterative multi‑frequency‑coupled HLF calculation method is proposed, improving the computational efficiency and stability. Finally, the accuracy of both the VSC harmonic model and HLF calculation method is validated through hardware‑in‑the‑loop simulations and electromagnetic transient simulations, respectively. Additionally, the model is applied to a modified IEEE 33‑bus test system for HLF study, and the frequency bands most sensitively affected by FC effects are identified.
- Open Access
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 20 (1) , e70425
A Mechanism–Data Hybrid‐Driven Dynamic Coupling Model for Grid‐Connected Harmonic Sources in Renewable Energy Systems
The large‐scale grid integration of renewable energy sources, such as wind and photovoltaic generation, relies on power electronic converters, whose nonlinear and time‐varying characteristics introduce severe harmonic pollution and threaten power quality and grid stability. Accurate harmonic source modelling is essential for harmonic assessment, localisation, and mitigation. However, traditional static mechanism‐based models are unable to accurately capture dynamic coupling between harmonic voltages and currents, while purely data‐driven models suffer from limited interpretability and high data requirements. To address these issues, this paper proposes a mechanism–data hybrid‐driven dynamic coupling model for harmonic sources. First, a harmonic coupling admittance matrix is established from a mechanism‐based perspective, and a variable forgetting factor recursive least squares (VFF‐RLS) algorithm is applied for online dynamic identification to adapt to operating condition variations. Subsequently, a data‐driven model integrating LSTM and an iTransformer enhanced with differential multi‐head attention is proposed to capture nonlinear dynamics and stochastic disturbances that are inadequately represented by the mechanism model. Experimental validation using measured wind and photovoltaic data demonstrates that the proposed model achieves high accuracy and stability across different harmonic orders, effectively characterising dynamic cross‐frequency coupling between harmonic currents and harmonic voltages.
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 20 (1) , e70425
Open AccessA Mechanism–Data Hybrid‐Driven Dynamic Coupling Model for Grid‐Connected Harmonic Sources in Renewable Energy Systems
The large‐scale grid integration of renewable energy sources, such as wind and photovoltaic generation, relies on power electronic converters, whose nonlinear and time‐varying characteristics introduce severe harmonic pollution and threaten power quality and grid stability. Accurate harmonic source modelling is essential for harmonic assessment, localisation, and mitigation. However, traditional static mechanism‐based models are unable to accurately capture dynamic coupling between harmonic voltages and currents, while purely data‐driven models suffer from limited interpretability and high data requirements. To address these issues, this paper proposes a mechanism–data hybrid‐driven dynamic coupling model for harmonic sources. First, a harmonic coupling admittance matrix is established from a mechanism‐based perspective, and a variable forgetting factor recursive least squares (VFF‐RLS) algorithm is applied for online dynamic identification to adapt to operating condition variations. Subsequently, a data‐driven model integrating LSTM and an iTransformer enhanced with differential multi‐head attention is proposed to capture nonlinear dynamics and stochastic disturbances that are inadequately represented by the mechanism model. Experimental validation using measured wind and photovoltaic data demonstrates that the proposed model achieves high accuracy and stability across different harmonic orders, effectively characterising dynamic cross‐frequency coupling between harmonic currents and harmonic voltages.