I. M. Markevtsev
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
I. M. Markevtsev has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- A. A. Agapov
Russian Federal Nuclear Center - All-Russian Research Institute of Experimental Physics (RFNC-VNIIEF) , 607188 Sarov
1 shared publication - A. P. Orlov
Russian Federal Nuclear Center - All-Russian Research Institute of Experimental Physics (RFNC-VNIIEF) , 607188 Sarov
1 shared publication - Alexey Filippov
Russian Federal Nuclear Center - All-Russian Research Institute of Experimental Physics (RFNC-VNIIEF) , 607188 Sarov
1 shared publication - B. G. Repin
Russian Federal Nuclear Center - All-Russian Research Institute of Experimental Physics (RFNC-VNIIEF) , 607188 Sarov
1 shared publication - D. S. Pokrovskiy
Russian Federal Nuclear Center - All-Russian Research Institute of Experimental Physics (RFNC-VNIIEF) , 607188 Sarov
1 shared publication - M. D. Baryshnikov
Russian Federal Nuclear Center - All-Russian Research Institute of Experimental Physics (RFNC-VNIIEF) , 607188 Sarov
1 shared publication
Latest Publications
- 1 September 2026
- Published by AIP Publishing in Physics of Plasmas
- Vol. 33 (9)
Generation of aluminum K -line in devices based on explosive magnetic generator
For several years, RFNC-VNIIEF has been conducting research on the generation of powerful soft x-ray (SXR) pulses during the stagnation of multi-wire cylindrical array systems powered by microsecond current pulses from both explosive and stationary current sources. In recent experiments generating the aluminum K-line using a helical explosive magnetic generator (EMG) with a 200 mm helix diameter, equipped with an explosive opening switch, the SXR pulse energy in the full spectrum reaches 70.4 kJ, and in the quantum energy range above 1 keV, it reaches 25.7 kJ, which is approximately 36% of the total radiation energy. The current pulse amplitude in the load is ∼5 MA, and the implosion time is ∼0.75–1 μs. The realized efficiency of the radiation generation with quantum energy above 1 keV is comparable with the best results obtained in the world's pulsed power installations with aluminum multi-wire loads. This paper presents the main results of the experimental studies conducted, as well as scaling calculations using the radiation magneto-hydrodynamic FLUX-rz and FLUX-3D codes to optimize the aluminum K-line generation for various load configurations powered by the helical EMG.
- 1 September 2026
- Published by AIP Publishing in Physics of Plasmas
- Vol. 33 (9)
Generation of aluminum K -line in devices based on explosive magnetic generator
For several years, RFNC-VNIIEF has been conducting research on the generation of powerful soft x-ray (SXR) pulses during the stagnation of multi-wire cylindrical array systems powered by microsecond current pulses from both explosive and stationary current sources. In recent experiments generating the aluminum K-line using a helical explosive magnetic generator (EMG) with a 200 mm helix diameter, equipped with an explosive opening switch, the SXR pulse energy in the full spectrum reaches 70.4 kJ, and in the quantum energy range above 1 keV, it reaches 25.7 kJ, which is approximately 36% of the total radiation energy. The current pulse amplitude in the load is ∼5 MA, and the implosion time is ∼0.75–1 μs. The realized efficiency of the radiation generation with quantum energy above 1 keV is comparable with the best results obtained in the world's pulsed power installations with aluminum multi-wire loads. This paper presents the main results of the experimental studies conducted, as well as scaling calculations using the radiation magneto-hydrodynamic FLUX-rz and FLUX-3D codes to optimize the aluminum K-line generation for various load configurations powered by the helical EMG.