O.I. Khomenko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
O.I. Khomenko has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Alexandre Khomenko
Odessa State Academy of Civil Engineering and Architecture
1 shared publication - Anna Holubenko
Odesa State Academy of Civil Engineering and Architecture
1 shared publication - E.A. Geraskina
Odessa State Academy of Civil Engineering and Architecture
1 shared publication - V.D. Petrash
Odesa State Academy of Civil Engineering and Architecture
1 shared publication - Volodymyr Makarov
Odesa State Academy of Civil Engineering and Architecture
1 shared publication
Latest Publications
- Open Access
- 29 September 2026
- Published by Odessa State Academy of Civil Engineering and Architecture in Modern construction and architecture
- No. 17,p. 85-91
INTERACTION OF BUILDING MATERIALS WITH AIR FLOWS IN PNEUMATIC CONVEYING AND ASPIRATION SYSTEMS
The article examines the features of the interaction of flows of bulk building materials with air flows in pneumatic transport and aspiration systems of construction industry enterprises. The relevance of the study is due to the fact that the processes of receiving, transporting and overloading bulk materials are accompanied by intensive dust emission, which is largely determined by the nature of the interaction of material and air streams. In modern practice of designing receiving devices and aspiration systems, these processes are mostly considered separately, without taking into account their interconnection, which leads to a decrease in the efficiency of aspiration installations and deterioration of operating conditions of production equipment. Based on the conducted research, the kinematic patterns of the addition of air masses to flows of bulk materials during their gravitational movement in gravity pipelines were determined. Analytical dependencies were obtained for determining the ejection pressure, volumes and air velocities that arise in the process of transporting the material. It is shown that the magnitude of the ejection pressure and the volume of air moving through gravity pipelines depend on the geometric parameters of the pipelines, the physical and mechanical properties of the material, the mass flow rate and the degree of tightness of the system. The patterns of static pressure distribution along the transport elements are established and the conditions for the formation of zones of excess and reduced pressure that affect the processes of dust emission are determined. Based on the results obtained, a scientifically substantiated method for calculating the aerodynamic parameters of aspiration sampling is proposed, which takes into account the ejection properties of bulk materials and the conditions of their transportation in gravity pipelines and transfer units. The proposed approach allows you to determine the required volumes of aspiration air, evaluate the parameters of dust air flows and increase the efficiency of aspiration systems. The results of the study can be used in engineering calculations and design of dust removal and pneumatic transport systems at construction industry enterprises.
- 29 September 2026
- Published by Odessa State Academy of Civil Engineering and Architecture in Modern construction and architecture
- No. 17,p. 85-91
Open AccessINTERACTION OF BUILDING MATERIALS WITH AIR FLOWS IN PNEUMATIC CONVEYING AND ASPIRATION SYSTEMS
The article examines the features of the interaction of flows of bulk building materials with air flows in pneumatic transport and aspiration systems of construction industry enterprises. The relevance of the study is due to the fact that the processes of receiving, transporting and overloading bulk materials are accompanied by intensive dust emission, which is largely determined by the nature of the interaction of material and air streams. In modern practice of designing receiving devices and aspiration systems, these processes are mostly considered separately, without taking into account their interconnection, which leads to a decrease in the efficiency of aspiration installations and deterioration of operating conditions of production equipment. Based on the conducted research, the kinematic patterns of the addition of air masses to flows of bulk materials during their gravitational movement in gravity pipelines were determined. Analytical dependencies were obtained for determining the ejection pressure, volumes and air velocities that arise in the process of transporting the material. It is shown that the magnitude of the ejection pressure and the volume of air moving through gravity pipelines depend on the geometric parameters of the pipelines, the physical and mechanical properties of the material, the mass flow rate and the degree of tightness of the system. The patterns of static pressure distribution along the transport elements are established and the conditions for the formation of zones of excess and reduced pressure that affect the processes of dust emission are determined. Based on the results obtained, a scientifically substantiated method for calculating the aerodynamic parameters of aspiration sampling is proposed, which takes into account the ejection properties of bulk materials and the conditions of their transportation in gravity pipelines and transfer units. The proposed approach allows you to determine the required volumes of aspiration air, evaluate the parameters of dust air flows and increase the efficiency of aspiration systems. The results of the study can be used in engineering calculations and design of dust removal and pneumatic transport systems at construction industry enterprises.
- Open Access
- 30 June 2026
- Published by Institute of Engineering Thermophysics of NAS of Ukraine in Thermophysics and Thermal Power Engineering
- Vol. 48 (2) , 113-123
POSSIBILITIES OF STEAM-COMPRESSION HEAT AND COOLING SUPPLY BASED ON ENERGY FROM A BINARY LOW-TEMPERATURE -SOURCE IN CONDITIONS OF REGULATED HEAT STORAG
The article is devoted to the development of opportunities and conceptual foundations for improving heat pump-based heating systems, including the development of new technical solutions for the rational combined use of binary low-temperature heat sources to provide energy-efficient heating and cooling for residential buildings during the relevant seasons. The aim of this work is to improve the structural and functional design of the proposed heating and cooling supply system, providing a theoretical justification for the efficient utilisation of the energy potential of the binary heat exchange system utilising ground heat and ventilation air flows. The paper establishes the relationship between the output parameters in the process of vapour-compression heat extraction from a low-temperature source in the evaporator, in accordance with the established relationship, as well as the conditions of its consumption by user subsystems downstream of the condenser under operational control conditions, forms the basis for a multi-factor assessment of the energy potential of a binary low-temperature source and the subsequent determination of the energy efficiency of the vapour compression heating and cooling system under consideration. It has been established that in buildings with sufficient thermal energy resources in the ventilation air, the use of an improved heat pump system allows for a further extension of the period during which recovered heat is accumulated in the soil mass – at the beginning and end of the heating season. It has been demonstrated that the start of heat accumulation in the ground mass in buildings with a heat pump heating system can be achieved in regions of Ukraine where the outdoor air temperature equals its average value for the heating season. The graphical relationships obtained show that an increase in the flow rate of the heat transfer medium through the ground heat exchanger, resulting from a reduction in the cross-sectional area of the heat exchanger used to cool the ventilation air, significantly reduces the system’s energy efficiency across the range of characteristic changes in circulating flow rates - through the evaporator 1 and condenser 3 GВ/GК over the entire considered range of outdoor air temperature variation (0...-18)°C. It has also been established that high energy efficiency in the conversion of energy flows in the analysed system can be achieved even under design conditions for the heating period (tзовн. = -18°C) with a ratio of circulating energy flow rates through the evaporator and the GВ/GК condenser > 1.8, provided that heat consumption is predominantly for heating and ventilation processes. The performance characteristics of the improved system utilising integrated heat demonstrate enhanced efficiency in the conversion of energy flows for the heating and cooling of buildings, which indirectly justifies the feasibility of maximising the storage of excess heat from air flows in the ground, combined with the simultaneous cooling of buildings during the non-heating season. It follows that the use of integrated heat not only allows for the implementation of a combined or sequential process of general energy extraction, rationally coordinated with the optimal operational control regime of heat consumption systems, but also to ensure highly efficient accumulation of excess heat from a low-temperature source in the soil mass for its subsequent use during the heating season. Conclusions. For the proposed vapour-compression heating and cooling system for buildings, a multifactorial relationship has been established for the actual conversion coefficient used to assess the efficiency of transforming low-grade heat from the ground and ventilation air. This allows for the analysis of the individual influence of parameters and operating modes of structural subsystems in the search for optimal conditions for utilising the energy of integrated flows for heating and cooling buildings during the relevant periods of the year. It has been established that high energy efficiency of the system is ensured under design and operating conditions during the heating season with a specific ratio of circulating energy carriers through the evaporator and condenser of the heat pump equipment.
- 30 June 2026
- Published by Institute of Engineering Thermophysics of NAS of Ukraine in Thermophysics and Thermal Power Engineering
- Vol. 48 (2) , 113-123
Open AccessPOSSIBILITIES OF STEAM-COMPRESSION HEAT AND COOLING SUPPLY BASED ON ENERGY FROM A BINARY LOW-TEMPERATURE -SOURCE IN CONDITIONS OF REGULATED HEAT STORAG
The article is devoted to the development of opportunities and conceptual foundations for improving heat pump-based heating systems, including the development of new technical solutions for the rational combined use of binary low-temperature heat sources to provide energy-efficient heating and cooling for residential buildings during the relevant seasons. The aim of this work is to improve the structural and functional design of the proposed heating and cooling supply system, providing a theoretical justification for the efficient utilisation of the energy potential of the binary heat exchange system utilising ground heat and ventilation air flows. The paper establishes the relationship between the output parameters in the process of vapour-compression heat extraction from a low-temperature source in the evaporator, in accordance with the established relationship, as well as the conditions of its consumption by user subsystems downstream of the condenser under operational control conditions, forms the basis for a multi-factor assessment of the energy potential of a binary low-temperature source and the subsequent determination of the energy efficiency of the vapour compression heating and cooling system under consideration. It has been established that in buildings with sufficient thermal energy resources in the ventilation air, the use of an improved heat pump system allows for a further extension of the period during which recovered heat is accumulated in the soil mass – at the beginning and end of the heating season. It has been demonstrated that the start of heat accumulation in the ground mass in buildings with a heat pump heating system can be achieved in regions of Ukraine where the outdoor air temperature equals its average value for the heating season. The graphical relationships obtained show that an increase in the flow rate of the heat transfer medium through the ground heat exchanger, resulting from a reduction in the cross-sectional area of the heat exchanger used to cool the ventilation air, significantly reduces the system’s energy efficiency across the range of characteristic changes in circulating flow rates - through the evaporator 1 and condenser 3 GВ/GК over the entire considered range of outdoor air temperature variation (0...-18)°C. It has also been established that high energy efficiency in the conversion of energy flows in the analysed system can be achieved even under design conditions for the heating period (tзовн. = -18°C) with a ratio of circulating energy flow rates through the evaporator and the GВ/GК condenser > 1.8, provided that heat consumption is predominantly for heating and ventilation processes. The performance characteristics of the improved system utilising integrated heat demonstrate enhanced efficiency in the conversion of energy flows for the heating and cooling of buildings, which indirectly justifies the feasibility of maximising the storage of excess heat from air flows in the ground, combined with the simultaneous cooling of buildings during the non-heating season. It follows that the use of integrated heat not only allows for the implementation of a combined or sequential process of general energy extraction, rationally coordinated with the optimal operational control regime of heat consumption systems, but also to ensure highly efficient accumulation of excess heat from a low-temperature source in the soil mass for its subsequent use during the heating season. Conclusions. For the proposed vapour-compression heating and cooling system for buildings, a multifactorial relationship has been established for the actual conversion coefficient used to assess the efficiency of transforming low-grade heat from the ground and ventilation air. This allows for the analysis of the individual influence of parameters and operating modes of structural subsystems in the search for optimal conditions for utilising the energy of integrated flows for heating and cooling buildings during the relevant periods of the year. It has been established that high energy efficiency of the system is ensured under design and operating conditions during the heating season with a specific ratio of circulating energy carriers through the evaporator and condenser of the heat pump equipment.