Cristiano Augusto Paulino de Alvarenga
Research Interests
Cristiano Augusto Paulino de Alvarenga has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Aline Soares Do Nascimento
São Leopoldo Mandic School of Dentistry
1 shared publication - Grace Kelly Moraes de Andrade Pinheiro
São Leopoldo Mandic School of Dentistry
1 shared publication - Igor Henrique Teixeira Fumagalli
Universidade de São Paulo, Brasil
1 shared publication - Iris Nogueira Bincelli Seckler
São Leopoldo Mandic School of Dentistry
1 shared publication - Marcos Frozoni
Faculdade São Leopoldo Mandic
1 shared publication - Renata Capelupe Simões Fumagalli
Universidade de São Paulo, Brasil
1 shared publication
Latest Publications
- Open Access
- 10 September 2026
- Published by Anima Educação in Journal of Research in Dentistry
- Vol. 14 (2) , 51-58
Evaluation of the Performance of Rotary Glide Path Instruments with Different Morphometric Characteristics in Reaching the Working Length.
Aims: To evaluate the performance and the time required for Rotate Glider 15/.04 and Univy Glider 15/.04 instruments to reach the working length in mesiobuccal canals of three-dimensional (3D) printed replicas of mandibular molars. Methods: Thirty replicas were divided into two groups (n = 15): Rotate Glider 15/.04 and Univy Glider 15/.04. Glide path preparation was performed using a VDW Silver motor at 350 rpm and 1.5 N/cm² torque. Ability to reach WL and required time were recorded by video analysis. Success was defined as reaching WL within nine pecking motions. Data were analyzed using Fisher’s exact and Student’s t-tests. Scanning electron microscopy evaluated instruments’ cutting angle, helical angle, spiral number, and cross-sectional design. Results: No statistically significant differences were observed between the tested instruments regarding the number of pecking motions required to reach the WL or the instrumentation time (p > 0.05). Morphological analysis demonstrated differences in geometric characteristics between the instruments; however, these differences did not influence their overall performance. Conclusions: Both rotary glide path instruments demonstrated similar and satisfactory performance in reaching the WL and may be safely used prior to mechanized root canal preparation procedures.
- 10 September 2026
- Published by Anima Educação in Journal of Research in Dentistry
- Vol. 14 (2) , 51-58
Open AccessEvaluation of the Performance of Rotary Glide Path Instruments with Different Morphometric Characteristics in Reaching the Working Length.
Aims: To evaluate the performance and the time required for Rotate Glider 15/.04 and Univy Glider 15/.04 instruments to reach the working length in mesiobuccal canals of three-dimensional (3D) printed replicas of mandibular molars. Methods: Thirty replicas were divided into two groups (n = 15): Rotate Glider 15/.04 and Univy Glider 15/.04. Glide path preparation was performed using a VDW Silver motor at 350 rpm and 1.5 N/cm² torque. Ability to reach WL and required time were recorded by video analysis. Success was defined as reaching WL within nine pecking motions. Data were analyzed using Fisher’s exact and Student’s t-tests. Scanning electron microscopy evaluated instruments’ cutting angle, helical angle, spiral number, and cross-sectional design. Results: No statistically significant differences were observed between the tested instruments regarding the number of pecking motions required to reach the WL or the instrumentation time (p > 0.05). Morphological analysis demonstrated differences in geometric characteristics between the instruments; however, these differences did not influence their overall performance. Conclusions: Both rotary glide path instruments demonstrated similar and satisfactory performance in reaching the WL and may be safely used prior to mechanized root canal preparation procedures.