Millie A. Barron
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Millie A. Barron has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Charlotte R. Sappo
Institute of Imaging Science Vanderbilt University Nashville Tennessee USA
3 shared publications - John C. Gore
Vanderbilt University Institute of Imaging Science, Nashville, TN, USA
2 shared publications - Jonathan B. Martin
Vanderbilt University Institute of Imaging Science Vanderbilt University Medical Center Nashville Tennessee USA
2 shared publications - Aaron R. Purchase
Department of Oncology, Division of Medical Physics, University of Alberta, Edmonton, AB, Canada
1 shared publication - Christopher E. Vaughn
Department of Biomedical Engineering Case Western Reserve University Cleveland Ohio USA
1 shared publication - Efraín Torres
Center for Magnetic Resonance Research and Department of Radiology University of Minnesota Minneapolis Minnesota USA
1 shared publication
Latest Publications
- Open Access
- 17 November 2026
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (12)
Development of RF Probes and Preamplifiers for MRI at Low Fields
Magnetic resonance imaging (MRI) systems operating at low magnetic fields ( T) have experienced renewed interest due to the emergence of portable, point‐of‐care (POC) scanners, and new approaches to mitigating the intrinsically lower signal‐to‐noise ratios (SNR). The performance of radiofrequency (RF) components is a large factor in determining overall system sensitivity. In contrast to conventional MRI, at higher fields where SNR is typically sample‐noise dominated, many low field (LF) systems operate in a coil‐noise dominated regime, requiring careful optimization of RF coil design, conductor losses, and receiver electronics. This manuscript surveys RF coil technologies and associated hardware considerations for MRI systems operating below approximately 0.18T, within the range that we designate as low field in this manuscript (0–250 mT). We begin by revisiting early low‐field imaging systems and the historical development of RF coil architectures for large‐volume imaging. The fundamental noise mechanisms governing low‐frequency MR detection are then examined, including Johnson noise in conductors, sample‐induced losses, receiver noise figure, and electromagnetic interference (EMI). Design strategies for improving sensitivity are discussed, including conductor optimization (e.g., Litz wire), coil geometry selection such as solenoidal and saddle configurations, and methods for managing coil bandwidth and quality factor. Recent developments in transmit‐receive switching, preamplifier design, EMI mitigation, and coil‐preamplifier co‐design are also reviewed. Finally, we highlight emerging directions for RF hardware development in low‐field MRI, including RF coils for encoding, multi‐element receive arrays for parallel imaging, and receiver architectures inspired by related modalities such as magnetic particle imaging and ultrasound. Continued advances in RF coil and receiver‐chain design will be essential for improving sensitivity and enabling low‐field MRI systems for clinical and research applications.
- 17 November 2026
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (12)
Open AccessDevelopment of RF Probes and Preamplifiers for MRI at Low Fields
Magnetic resonance imaging (MRI) systems operating at low magnetic fields ( T) have experienced renewed interest due to the emergence of portable, point‐of‐care (POC) scanners, and new approaches to mitigating the intrinsically lower signal‐to‐noise ratios (SNR). The performance of radiofrequency (RF) components is a large factor in determining overall system sensitivity. In contrast to conventional MRI, at higher fields where SNR is typically sample‐noise dominated, many low field (LF) systems operate in a coil‐noise dominated regime, requiring careful optimization of RF coil design, conductor losses, and receiver electronics. This manuscript surveys RF coil technologies and associated hardware considerations for MRI systems operating below approximately 0.18T, within the range that we designate as low field in this manuscript (0–250 mT). We begin by revisiting early low‐field imaging systems and the historical development of RF coil architectures for large‐volume imaging. The fundamental noise mechanisms governing low‐frequency MR detection are then examined, including Johnson noise in conductors, sample‐induced losses, receiver noise figure, and electromagnetic interference (EMI). Design strategies for improving sensitivity are discussed, including conductor optimization (e.g., Litz wire), coil geometry selection such as solenoidal and saddle configurations, and methods for managing coil bandwidth and quality factor. Recent developments in transmit‐receive switching, preamplifier design, EMI mitigation, and coil‐preamplifier co‐design are also reviewed. Finally, we highlight emerging directions for RF hardware development in low‐field MRI, including RF coils for encoding, multi‐element receive arrays for parallel imaging, and receiver architectures inspired by related modalities such as magnetic particle imaging and ultrasound. Continued advances in RF coil and receiver‐chain design will be essential for improving sensitivity and enabling low‐field MRI systems for clinical and research applications.
- Open Access
- 17 November 2026
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 393
Diffusion imaging with a pulsed radiofrequency gradient spin-echo
- 17 November 2026
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 393
Open AccessDiffusion imaging with a pulsed radiofrequency gradient spin-echo
- Open Access
- 17 September 2026
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 135
Radiofrequency field gradient encoding methods and applications for magnetic resonance imaging
- 17 September 2026
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 135
Open AccessRadiofrequency field gradient encoding methods and applications for magnetic resonance imaging