KAKazunori Asakura

Kazunori Asakura

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kazunori Asakura has a total of 53 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    CCD driving technique to suppress anomalous charge intrusion from outside the imaging area for soft X-ray imager of Xtend onboard XRISM

    by Hirofumi Noda, Mio Aoyagi, Koji Mori, Hiroshi Tomida, Hiroshi Nakajima, Takaaki Tanaka, Hiromasa Suzuki, Hiroshi Murakami, Hiroyuki Uchida, Takeshi G. Tsuru, et al.

    The X-Ray Imaging and Spectroscopy Mission (XRISM) is the seventh X-ray astronomical satellite of Japan, successfully launched on September 7, 2023 (JST). It is equipped with two soft X-ray observational instruments.1 One is the soft X-ray spectroscopic telescope, Resolve, which combines an X-ray Mirror Assembly (XMA)2 and an X-ray microcalorimeter.3 The other is the soft X-ray imaging telescope, Xtend, which combines an XMA4 and an X-ray charge-coupled device (CCD) camera.5 The X-ray microcalorimeter of Resolve achieves unprecedentedly high energy resolution compared with previous X-ray detectors, allowing it to resolve fine spectral features that are blurred in conventional X-ray observations. Xtend achieves a wide field of view (FOV) of 38′×38′ in the 0.4 to 13 keV range, which is crucial for maximizing the spectroscopic performance of Resolve. For example, Xtend can precisely evaluate the contamination in the Resolve FOV (2.9′×2.9′) from outside sources by utilizing its wide FOV. When Resolve observes a point source within a diffuse object, emission from the diffuse object might contaminate the spectrum. Xtend can assess this contamination, allowing accurate extraction of target signals from a precise spectrum of Resolve. In addition, Xtend can complete some orbital operations and calibrations that Resolve alone cannot, such as the initial alignment of the XMA central axis and detector aim point. The pixel size of Resolve is 832  μm, whereas the CCD camera of Xtend has a pixel size of 24  μm, enabling Xtend to achieve more precise alignment than the PSF core of XMA. Naturally, Xtend is powerful not only in combination with Resolve but also on its own, capable of observing broadly extended diffuse sources and discovering new transient objects in its wide FOV, even during a single pointing observation.

  • Multi-image X-ray interferometer module: II. Demonstration of high-resolution X-ray imaging with regular-interval coded apertures

    by Kazunori Asakura, Kiyoshi Hayashida, Tomokage Yoneyama, Hirofumi Noda, Marina Yoshimoto, Tomohiro Hakamata, Hironori Matsumoto, Hiroshi Tsunemi

    We have been developing an X-ray imaging system, multi-image X-ray interferometer module (MIXIM), to achieve a high angular resolution with a compact system size. MIXIM is comprised of a mask with equally spaced apertures and an X-ray detector. The aperture size and the mask-detector distance determine the system’s angular resolution. Although a smaller aperture gives a better resolution, the degree of improvement is limited by a diffraction effect. MIXIM circumvents this problem by utilizing the Talbot effect. Our experiment with the previous model equipped with a multi-pinhole mask obtained an angular resolution of 0.5″ with a mask-detector distance of 92 cm. A major downside of the multi-pinhole mask is, however, that it has a very low opening fraction, which results in a very low effective area. Here, we newly adopt a multiple coded aperture (MCA) mask, an array of coded aperture patterns. Our proof-of-concept experiment demonstrates that the Talbot effect works even for the MCA mask with a high opening fraction of ∼50% at 12.4 keV. Consequently, the new MIXIM realizes ∼25 times as large an effective area as that of the previous model while maintaining a high angular resolution of 0.2″ and a compact size of ∼1.5 m.


  • Multi-image x-ray interferometer module: I. Design concept and proof-of-concept experiments with fine-pitch slits

    by Kazunori Asakura, Kiyoshi Hayashida, Tomoki Kawabata, Yoneyama Tomokage, Hirofumi Noda, Hironori Matsumoto, Hiroshi Tsunemi, Hiroshi Nakajima, Hisamitsu Awaki, Junko S. Hiraga

    We propose an x-ray imaging system, multi-image x-ray interferometer module (MIXIM), with which a very high angular resolution can be achieved even with a small system size. MIXIM is composed of equally spaced multiple slits and an x-ray detector, and its angular resolution is inversely proportional to the distance between them. Here, we report our evaluation experiments of MIXIM with a newly adopted CMOS sensor with a high spatial resolution of 2.5 μm. Our previous experiments with a prototype MIXIM were limited to one-dimensional imaging, and more importantly, the achieved angular resolution was only ∼1 ″ , severely constrained due to the spatial resolution of the adopted sensor with a pixel size of 4.25 μm. By contrast, one-dimensional images obtained in this experiment had a higher angular resolution of 0.5″ when a configured system size was only ∼1 m, which demonstrates that MIXIM can simultaneously realize a high angular resolution and compact size. We also successfully obtained a two-dimensional profile of an x-ray beam for the first time for MIXIM by introducing a periodic pinhole mask. The highest angular resolution achieved in our experiments is smaller than 0.1″ with a mask-sensor distance of 866.5 cm, which shows the high scalability of MIXIM.


  • Open Access

    Measuring the atomic scattering factors near the iridium L-edges for the Athena silicon pore optics reflector

    by Hisamitsu Awaki, Yoshitomo Maeda, Hironori Matsumoto, Sara Svendsen, Marcos Bavdaz, Maximilien Collon, Kazunori Asakura, Finn E. Christensen, Desiree D. M. Ferreira, Matteo Guainazzi, et al.

    The Advanced Telescope for High-Energy Astrophysics (Athena)1 is a next-generation x-ray telescope to be developed by the European Space Agency (ESA) as a part of its Cosmic Vision L2 program. Athena is expected to operate in the energy range of 0.2 to 12 keV and realize the advanced x-ray imaging and spectroscopy of the hot Universe. The key scientific objectives are to determine how and when large-scale hot gas structures formed in the Universe, to perform a complete census of black hole growth in the Universe, and explore high-energy phenomena, which are expected to provide a valuable basis for astrophysics research in the 2030s.


  • X-ray imaging polarimetry with a 2.5-μm pixel CMOS sensor for visible light at room temperature

    by Kazunori Asakura, Kiyoshi Hayashida, Takashi Hanasaka, Tomoki Kawabata, Tomokage Yoneyama, Koki Okazaki, Shuntaro Ide, Hirofumi Noda, Hironori Matsumoto, Hiroshi Tsunemi, et al.

    X-ray polarimetry in astronomy has not been exploited well, despite its importance. The recent innovation of instruments is changing this situation. We focus on a complementary metal–oxide–semiconductor (CMOS) pixel detector with small pixel size and employ it as an x-ray photoelectron tracking polarimeter. The CMOS detector we employ is developed by GPixel Inc. and has a pixel size of 2.5 μm × 2.5 μm. Although it is designed for visible light, we succeed in detecting x-ray photons with an energy resolution of 176 eV (FWHM) at 5.9 keV at room temperature and the atmospheric condition. We measure the x-ray detection efficiency and polarimetry sensitivity by irradiating polarized monochromatic x-rays at BL20B2 in SPring-8, the synchrotron radiation facility in Japan. We obtain modulation factors of 7.63 % ± 0.07 % and 15.5 % ± 0.4 % at 12.4 and 24.8 keV, respectively. It demonstrates that this sensor can be used as an x-ray imaging spectrometer and polarimeter with the highest spatial resolution ever tested.