Hiroshi Tsunemi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hiroshi Tsunemi has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
Kiyoshi Hayashida
Osaka Univ
5 shared publicationsHironori Matsumoto
Osaka Univ
4 shared publications- Hiroshi Nakajima
College of Science and Engineering, Kanto Gakuin University
4 shared publications Hirofumi Noda
Tōhoku Univ
3 shared publicationsJunko S. Hiraga
National Astronomical Observatory of Japan
3 shared publications- Kazunori Asakura
Osaka University, Graduate School of Science, Department of Earth and Space Science, Toyonaka, Japan
3 shared publications
Latest Publications
- Open Access
- 11 March 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 11 (04) , 042003-14
Initial operations of the Soft X-ray Imager onboard XRISM
X-Ray Imaging and Spectroscopy Mission (XRISM)1 – 3 is Japan’s seventh X-ray astronomical satellite mission, which is equipped with the microcalorimeter “Resolve”4 and charge-coupled device (CCD) camera “Xtend”5 – 7 in combination with the X-ray mirror assemblies.8,9 XRISM was successfully launched into a low-earth orbit on September 6, 2023 (UT). The focal plane detector of Xtend is the Soft X-ray Imager (SXI), which consists of back-illuminated, fully depleted X-ray CCDs.10,11 Xtend is designed to cover a large field of view () with an angular resolution of [Half Power Diameter (HPD)]. The required energy resolution is [full-width half maximum (FWHM)] at 6 keV, typical for X-ray CCD sensors.- 11 March 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 11 (04) , 042003-14
Open AccessInitial operations of the Soft X-ray Imager onboard XRISM
X-Ray Imaging and Spectroscopy Mission (XRISM)1 – 3 is Japan’s seventh X-ray astronomical satellite mission, which is equipped with the microcalorimeter “Resolve”4 and charge-coupled device (CCD) camera “Xtend”5 – 7 in combination with the X-ray mirror assemblies.8,9 XRISM was successfully launched into a low-earth orbit on September 6, 2023 (UT). The focal plane detector of Xtend is the Soft X-ray Imager (SXI), which consists of back-illuminated, fully depleted X-ray CCDs.10,11 Xtend is designed to cover a large field of view () with an angular resolution of [Half Power Diameter (HPD)]. The required energy resolution is [full-width half maximum (FWHM)] at 6 keV, typical for X-ray CCD sensors. - 1 October 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 10 (04) , 045002-13
Multi-image X-ray interferometer module: II. Demonstration of high-resolution X-ray imaging with regular-interval coded apertures
We have been developing an X-ray imaging system, multi-image X-ray interferometer module (MIXIM), to achieve a high angular resolution with a compact system size. MIXIM is comprised of a mask with equally spaced apertures and an X-ray detector. The aperture size and the mask-detector distance determine the system’s angular resolution. Although a smaller aperture gives a better resolution, the degree of improvement is limited by a diffraction effect. MIXIM circumvents this problem by utilizing the Talbot effect. Our experiment with the previous model equipped with a multi-pinhole mask obtained an angular resolution of 0.5″ with a mask-detector distance of 92 cm. A major downside of the multi-pinhole mask is, however, that it has a very low opening fraction, which results in a very low effective area. Here, we newly adopt a multiple coded aperture (MCA) mask, an array of coded aperture patterns. Our proof-of-concept experiment demonstrates that the Talbot effect works even for the MCA mask with a high opening fraction of ∼50% at 12.4 keV. Consequently, the new MIXIM realizes ∼25 times as large an effective area as that of the previous model while maintaining a high angular resolution of 0.2″ and a compact size of ∼1.5 m.
- 1 October 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 10 (04) , 045002-13
Multi-image X-ray interferometer module: II. Demonstration of high-resolution X-ray imaging with regular-interval coded apertures
We have been developing an X-ray imaging system, multi-image X-ray interferometer module (MIXIM), to achieve a high angular resolution with a compact system size. MIXIM is comprised of a mask with equally spaced apertures and an X-ray detector. The aperture size and the mask-detector distance determine the system’s angular resolution. Although a smaller aperture gives a better resolution, the degree of improvement is limited by a diffraction effect. MIXIM circumvents this problem by utilizing the Talbot effect. Our experiment with the previous model equipped with a multi-pinhole mask obtained an angular resolution of 0.5″ with a mask-detector distance of 92 cm. A major downside of the multi-pinhole mask is, however, that it has a very low opening fraction, which results in a very low effective area. Here, we newly adopt a multiple coded aperture (MCA) mask, an array of coded aperture patterns. Our proof-of-concept experiment demonstrates that the Talbot effect works even for the MCA mask with a high opening fraction of ∼50% at 12.4 keV. Consequently, the new MIXIM realizes ∼25 times as large an effective area as that of the previous model while maintaining a high angular resolution of 0.2″ and a compact size of ∼1.5 m.
- 1 April 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 9 (02) , 025004-16
Multi-image x-ray interferometer module: I. Design concept and proof-of-concept experiments with fine-pitch slits
We propose an x-ray imaging system, multi-image x-ray interferometer module (MIXIM), with which a very high angular resolution can be achieved even with a small system size. MIXIM is composed of equally spaced multiple slits and an x-ray detector, and its angular resolution is inversely proportional to the distance between them. Here, we report our evaluation experiments of MIXIM with a newly adopted CMOS sensor with a high spatial resolution of 2.5 μm. Our previous experiments with a prototype MIXIM were limited to one-dimensional imaging, and more importantly, the achieved angular resolution was only ∼1 ″ , severely constrained due to the spatial resolution of the adopted sensor with a pixel size of 4.25 μm. By contrast, one-dimensional images obtained in this experiment had a higher angular resolution of 0.5″ when a configured system size was only ∼1 m, which demonstrates that MIXIM can simultaneously realize a high angular resolution and compact size. We also successfully obtained a two-dimensional profile of an x-ray beam for the first time for MIXIM by introducing a periodic pinhole mask. The highest angular resolution achieved in our experiments is smaller than 0.1″ with a mask-sensor distance of 866.5 cm, which shows the high scalability of MIXIM.
- 1 April 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 9 (02) , 025004-16
Multi-image x-ray interferometer module: I. Design concept and proof-of-concept experiments with fine-pitch slits
We propose an x-ray imaging system, multi-image x-ray interferometer module (MIXIM), with which a very high angular resolution can be achieved even with a small system size. MIXIM is composed of equally spaced multiple slits and an x-ray detector, and its angular resolution is inversely proportional to the distance between them. Here, we report our evaluation experiments of MIXIM with a newly adopted CMOS sensor with a high spatial resolution of 2.5 μm. Our previous experiments with a prototype MIXIM were limited to one-dimensional imaging, and more importantly, the achieved angular resolution was only ∼1 ″ , severely constrained due to the spatial resolution of the adopted sensor with a pixel size of 4.25 μm. By contrast, one-dimensional images obtained in this experiment had a higher angular resolution of 0.5″ when a configured system size was only ∼1 m, which demonstrates that MIXIM can simultaneously realize a high angular resolution and compact size. We also successfully obtained a two-dimensional profile of an x-ray beam for the first time for MIXIM by introducing a periodic pinhole mask. The highest angular resolution achieved in our experiments is smaller than 0.1″ with a mask-sensor distance of 866.5 cm, which shows the high scalability of MIXIM.
- 6 June 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 5 (03) , 035002-7
X-ray imaging polarimetry with a 2.5-μm pixel CMOS sensor for visible light at room temperature
X-ray polarimetry in astronomy has not been exploited well, despite its importance. The recent innovation of instruments is changing this situation. We focus on a complementary metal–oxide–semiconductor (CMOS) pixel detector with small pixel size and employ it as an x-ray photoelectron tracking polarimeter. The CMOS detector we employ is developed by GPixel Inc. and has a pixel size of 2.5 μm × 2.5 μm. Although it is designed for visible light, we succeed in detecting x-ray photons with an energy resolution of 176 eV (FWHM) at 5.9 keV at room temperature and the atmospheric condition. We measure the x-ray detection efficiency and polarimetry sensitivity by irradiating polarized monochromatic x-rays at BL20B2 in SPring-8, the synchrotron radiation facility in Japan. We obtain modulation factors of 7.63 % ± 0.07 % and 15.5 % ± 0.4 % at 12.4 and 24.8 keV, respectively. It demonstrates that this sensor can be used as an x-ray imaging spectrometer and polarimeter with the highest spatial resolution ever tested.
- 6 June 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 5 (03) , 035002-7
X-ray imaging polarimetry with a 2.5-μm pixel CMOS sensor for visible light at room temperature
X-ray polarimetry in astronomy has not been exploited well, despite its importance. The recent innovation of instruments is changing this situation. We focus on a complementary metal–oxide–semiconductor (CMOS) pixel detector with small pixel size and employ it as an x-ray photoelectron tracking polarimeter. The CMOS detector we employ is developed by GPixel Inc. and has a pixel size of 2.5 μm × 2.5 μm. Although it is designed for visible light, we succeed in detecting x-ray photons with an energy resolution of 176 eV (FWHM) at 5.9 keV at room temperature and the atmospheric condition. We measure the x-ray detection efficiency and polarimetry sensitivity by irradiating polarized monochromatic x-rays at BL20B2 in SPring-8, the synchrotron radiation facility in Japan. We obtain modulation factors of 7.63 % ± 0.07 % and 15.5 % ± 0.4 % at 12.4 and 24.8 keV, respectively. It demonstrates that this sensor can be used as an x-ray imaging spectrometer and polarimeter with the highest spatial resolution ever tested.
- Open Access
- 14 February 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 4 (01) , 011211-15
Soft X-ray Imager aboard Hitomi (ASTRO-H)
Hitomi,1,2 formerly known as ASTRO-H, is the sixth Japanese x-ray astronomy satellite, which was launched on February 17, 2016, aboard an H-IIA rocket from JAXA’s Tanegashima Space Center. The Soft X-ray Imager (SXI)3 4. 5. 6. 7. 8. – 9 is an imaging spectrometer aboard Hitomi covering the energy range between 0.4 and 12 keV. X-rays are focused by the Wolter type I mirror optics, the Soft X-ray Telescope (SXT-I),10 with a focal length of 5.6 m. An array of x-ray charge-coupled devices (CCDs) covers a large field of view (FoV) of . Almost the same energy range as the SXI is covered also by the Soft X-ray Spectrometer (SXS),11 which features a superb energy resolution of in full width at half maximum (FWHM) for 6 keV x-rays. However, the microcalorimeter array of the SXS covers only a small FoV of and the imaging capability is limited. The SXI, with its large FoV and small pixels, plays a complimentary role.- 14 February 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 4 (01) , 011211-15
Open AccessSoft X-ray Imager aboard Hitomi (ASTRO-H)
Hitomi,1,2 formerly known as ASTRO-H, is the sixth Japanese x-ray astronomy satellite, which was launched on February 17, 2016, aboard an H-IIA rocket from JAXA’s Tanegashima Space Center. The Soft X-ray Imager (SXI)3 4. 5. 6. 7. 8. – 9 is an imaging spectrometer aboard Hitomi covering the energy range between 0.4 and 12 keV. X-rays are focused by the Wolter type I mirror optics, the Soft X-ray Telescope (SXT-I),10 with a focal length of 5.6 m. An array of x-ray charge-coupled devices (CCDs) covers a large field of view (FoV) of . Almost the same energy range as the SXI is covered also by the Soft X-ray Spectrometer (SXS),11 which features a superb energy resolution of in full width at half maximum (FWHM) for 6 keV x-rays. However, the microcalorimeter array of the SXS covers only a small FoV of and the imaging capability is limited. The SXI, with its large FoV and small pixels, plays a complimentary role.