Junichiro Sado Junior
Research Subjects
Junichiro Sado Junior has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Andrei Machado Viegas da Trindade
Faculty of Medicine, University Evangelica of Goiás, Anápolis 75083-515, Brazil
2 shared publications - Claudia Santos Oliveira
Health Sciences Program, Santa Casa de São Paulo School of Medical Sciences, São Paulo 01221-020, SP, Brazil
2 shared publications - Helder Rocha da Silva Araújo
Department of Orthopaedics and Traumatology, Federal University of Goiás (UFG), Goiânia 74605-050, Brazil
2 shared publications - Karla Cristina Naves De Carvalho
Faculty of Medicine, University Evangelica of Goiás, Anápolis 75083-515, GO, Brazil
2 shared publications - Leonardo Pinheiro Rezende
Faculty of Medicine, University Evangelica of Goiás, Anápolis 75083-515, Brazil
2 shared publications - Rodolfo Borges Parreira
Human Movement Analysis Laboratory, University Evangelica of Goiás, Anápolis 75083-515, Brazil
2 shared publications
Latest Publications
- Open Access
- 14 October 2026
- Published by MDPI AG in Journal of Functional Morphology and Kinesiology
- Vol. 11 (4) , 420
Dissociation Between Instrumented Mobility and Self-Reported Function in Adults Aged 70 Years or Older After Unilateral Total Knee Arthroplasty: A Preliminary Longitudinal Study Using an Inertial Sensor and the WOMAC
Background and Objectives: Total knee arthroplasty (TKA) reliably reduces pain and improves self-reported function, yet objective mobility may remain impaired in older adults. We examined the relationship between inertial-sensor-based mobility and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) in adults aged 70 years or older after unilateral TKA. Methods: In this observational longitudinal study, 25 participants were assessed at up to three postoperative time points (M1, first available assessment; M2, 2024 follow-up; M3, 2025 follow-up). Outcomes were the instrumented Timed Up and Go (TUG) test with segmented turning variables, the 2-Minute Walk Test (2MWT), spatiotemporal gait variables recorded with a trunk-mounted inertial measurement unit, and the WOMAC. Paired changes in the instrumented outcomes were tested with Wilcoxon signed-rank tests under Benjamini–Hochberg false-discovery-rate (FDR) control and are reported with bootstrap confidence intervals (CIs); longitudinal change in the WOMAC was not tested, because the response format used at the first assessment could not be established from the available records, so WOMAC scores are used only within time point; associations used Spearman correlations with bootstrap CIs and leave-one-out influence diagnostics. Individual-level agreement was examined by standardising each of three externally validated objective outcomes against the inverted WOMAC total score within time point and classifying discordance across a range of cut-offs. Observed changes in the instrumented outcomes were benchmarked against published minimal detectable change (MDC) values. Results: Participants were 75.56 ± 4.00 years old and 64.0% were women; 14 were reassessed at M2 and 2 at M3. No instrumented global outcome changed after FDR adjustment, and the median changes in total TUG time (+0.07 s) and 2MWT distance (+12.80 m) remained below published MDC95 values (2.27 s and 14.96 m). Mid-turn duration shortened by a median of 0.80 s (95% CI −0.93 to −0.28) and mid-turn peak and mean angular velocities increased by 16.55°/s (8.00 to 30.10) and 7.40°/s (1.30 to 14.15), all with FDR-adjusted p = 0.036. At M2, the WOMAC total score was inversely associated with walking speed (rho = −0.762, 95% CI −0.973 to −0.307), cadence (rho = −0.761) and 2MWT distance (rho = −0.644); these three associations retained their sign and significance in every leave-one-out refit and changed little on adjustment for age, body mass index or postoperative duration, whereas all M1 associations were weak. Between 42.9% and 57.1% of participants fell outside a ±0.5 standardised concordance band at M2 depending on which validated outcome was used, with no consistent asymmetry in either direction, and the estimated prevalence ranged from 7.1% to 85.7% across plausible cut-offs. Conclusions: Group-level association between patient-reported and instrumented outcomes coexists with frequent individual-level discordance, but the magnitude of that discordance is not stably estimable in a cohort of this size. WOMAC scores should not be assumed to substitute for objective mobility testing after TKA, and confirmation in larger prospective cohorts is required.
- 14 October 2026
- Published by MDPI AG in Journal of Functional Morphology and Kinesiology
- Vol. 11 (4) , 420
Open AccessDissociation Between Instrumented Mobility and Self-Reported Function in Adults Aged 70 Years or Older After Unilateral Total Knee Arthroplasty: A Preliminary Longitudinal Study Using an Inertial Sensor and the WOMAC
Background and Objectives: Total knee arthroplasty (TKA) reliably reduces pain and improves self-reported function, yet objective mobility may remain impaired in older adults. We examined the relationship between inertial-sensor-based mobility and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) in adults aged 70 years or older after unilateral TKA. Methods: In this observational longitudinal study, 25 participants were assessed at up to three postoperative time points (M1, first available assessment; M2, 2024 follow-up; M3, 2025 follow-up). Outcomes were the instrumented Timed Up and Go (TUG) test with segmented turning variables, the 2-Minute Walk Test (2MWT), spatiotemporal gait variables recorded with a trunk-mounted inertial measurement unit, and the WOMAC. Paired changes in the instrumented outcomes were tested with Wilcoxon signed-rank tests under Benjamini–Hochberg false-discovery-rate (FDR) control and are reported with bootstrap confidence intervals (CIs); longitudinal change in the WOMAC was not tested, because the response format used at the first assessment could not be established from the available records, so WOMAC scores are used only within time point; associations used Spearman correlations with bootstrap CIs and leave-one-out influence diagnostics. Individual-level agreement was examined by standardising each of three externally validated objective outcomes against the inverted WOMAC total score within time point and classifying discordance across a range of cut-offs. Observed changes in the instrumented outcomes were benchmarked against published minimal detectable change (MDC) values. Results: Participants were 75.56 ± 4.00 years old and 64.0% were women; 14 were reassessed at M2 and 2 at M3. No instrumented global outcome changed after FDR adjustment, and the median changes in total TUG time (+0.07 s) and 2MWT distance (+12.80 m) remained below published MDC95 values (2.27 s and 14.96 m). Mid-turn duration shortened by a median of 0.80 s (95% CI −0.93 to −0.28) and mid-turn peak and mean angular velocities increased by 16.55°/s (8.00 to 30.10) and 7.40°/s (1.30 to 14.15), all with FDR-adjusted p = 0.036. At M2, the WOMAC total score was inversely associated with walking speed (rho = −0.762, 95% CI −0.973 to −0.307), cadence (rho = −0.761) and 2MWT distance (rho = −0.644); these three associations retained their sign and significance in every leave-one-out refit and changed little on adjustment for age, body mass index or postoperative duration, whereas all M1 associations were weak. Between 42.9% and 57.1% of participants fell outside a ±0.5 standardised concordance band at M2 depending on which validated outcome was used, with no consistent asymmetry in either direction, and the estimated prevalence ranged from 7.1% to 85.7% across plausible cut-offs. Conclusions: Group-level association between patient-reported and instrumented outcomes coexists with frequent individual-level discordance, but the magnitude of that discordance is not stably estimable in a cohort of this size. WOMAC scores should not be assumed to substitute for objective mobility testing after TKA, and confirmation in larger prospective cohorts is required.
- Open Access
- 25 September 2026
- Published by MDPI AG in Journal of Functional Morphology and Kinesiology
- Vol. 11 (4) , 384
Global Spatiotemporal Gait Performance and Ambulation Capacity After Total Knee Arthroplasty: A Longitudinal Comparison of Fixed-Bearing and Mobile-Bearing Prostheses
Background: The choice between fixed-bearing (FB) and mobile-bearing (MB) prostheses in total knee arthroplasty (TKA) remains controversial, and longitudinal evidence based on objective instrumented assessment is limited. Objectives: To compare global spatiotemporal gait performance and ambulation capacity across three postoperative assessments in patients receiving FB versus MB/rotating-platform implants. Methods: In this retrospective, longitudinal, observational cohort study, patients who had undergone primary unilateral TKA were assessed at up to three postoperative visits approximately 12 months apart, the first at a median of 12 months after surgery. Gait speed, cadence, stride length, a step-time symmetry index and a gait quality index were obtained from a single lumbar-mounted inertial measurement unit during steady-state level walking, and ambulation capacity was measured with the 2-Minute Walk Test (2MWT). Linear mixed-effects models with a random intercept per patient, adjusted for age and sex, were fitted for all six outcomes, with time specified both as a linear term and, in a sensitivity analysis, as a categorical factor yielding estimated marginal means and between-group contrasts at each visit. Results: A total of 105 observations from 54 patients were analysed (29 FB, 25 MB/PS-RP). Groups were comparable at the first assessment on age, sex, body mass index, WOMAC score and all gait outcomes. No between-group difference reached statistical significance for any outcome, in either the linear or the categorical specification; all 18 visit-specific contrasts included the null value. Within the FB group, gait speed, stride length, the symmetry index, the gait quality index and 2MWT distance decreased significantly between the second and third assessments, a change based on six patients. Conclusions: Under the conditions of this study, no significant differences in global spatiotemporal gait performance or ambulation capacity were detected between FB and MB/rotating-platform prostheses. Because the study was not designed or powered as an equivalence trial, lacks preoperative and joint-level kinematic data, and cannot separate bearing design from the surgical approach with which it was collinear, these findings do not establish that the two designs perform equivalently.
- 25 September 2026
- Published by MDPI AG in Journal of Functional Morphology and Kinesiology
- Vol. 11 (4) , 384
Open AccessGlobal Spatiotemporal Gait Performance and Ambulation Capacity After Total Knee Arthroplasty: A Longitudinal Comparison of Fixed-Bearing and Mobile-Bearing Prostheses
Background: The choice between fixed-bearing (FB) and mobile-bearing (MB) prostheses in total knee arthroplasty (TKA) remains controversial, and longitudinal evidence based on objective instrumented assessment is limited. Objectives: To compare global spatiotemporal gait performance and ambulation capacity across three postoperative assessments in patients receiving FB versus MB/rotating-platform implants. Methods: In this retrospective, longitudinal, observational cohort study, patients who had undergone primary unilateral TKA were assessed at up to three postoperative visits approximately 12 months apart, the first at a median of 12 months after surgery. Gait speed, cadence, stride length, a step-time symmetry index and a gait quality index were obtained from a single lumbar-mounted inertial measurement unit during steady-state level walking, and ambulation capacity was measured with the 2-Minute Walk Test (2MWT). Linear mixed-effects models with a random intercept per patient, adjusted for age and sex, were fitted for all six outcomes, with time specified both as a linear term and, in a sensitivity analysis, as a categorical factor yielding estimated marginal means and between-group contrasts at each visit. Results: A total of 105 observations from 54 patients were analysed (29 FB, 25 MB/PS-RP). Groups were comparable at the first assessment on age, sex, body mass index, WOMAC score and all gait outcomes. No between-group difference reached statistical significance for any outcome, in either the linear or the categorical specification; all 18 visit-specific contrasts included the null value. Within the FB group, gait speed, stride length, the symmetry index, the gait quality index and 2MWT distance decreased significantly between the second and third assessments, a change based on six patients. Conclusions: Under the conditions of this study, no significant differences in global spatiotemporal gait performance or ambulation capacity were detected between FB and MB/rotating-platform prostheses. Because the study was not designed or powered as an equivalence trial, lacks preoperative and joint-level kinematic data, and cannot separate bearing design from the surgical approach with which it was collinear, these findings do not establish that the two designs perform equivalently.