David Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
David Huang has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Yali Jia
Oregon Health and Science University
6 shared publications Alex D. Pechauer
Casey Eye Institute
3 shared publicationsJie Wang
Oregon Health and Science University, Casey Eye Institute, Portland, Oregon
3 shared publications- Simon S. Gao
Genentech, Inc., South San Francisco, California
3 shared publications Acner Camino
Oregon Health and Science University, Casey Eye Institute, Portland, Oregon
2 shared publicationsBradley A. Bower
Duke Univ. (United States)
2 shared publications
Latest Publications
- Open Access
- 12 September 2019
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 6 (04) , 041108-9
Detecting and measuring areas of choriocapillaris low perfusion in intermediate, non-neovascular age-related macular degeneration
Optical coherence tomography angiography (OCTA)1,2 is an imaging modality that allows depth-resolved and noninvasive imaging of the retinal and choroidal flow.3 – 7 OCTA algorithms use the variation of optical coherence tomography (OCT) signal over time to detect blood flow against avascular tissue. Although significantly attenuated by the highly scattering retinal pigment epithelium (RPE), the OCT signal incoming from the choriocapillaris layer is generally enough to retrieve the blood flow information in both spectral domain and swept source OCT. Although the resolution of current OCTA devices is not sufficient to resolve either the true caliber of choroidal capillaries or the minuscule intravascular spaces,8 signal defects such as flow voids are large enough to be detected and measured.5,7
- 12 September 2019
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 6 (04) , 041108-9
Open AccessDetecting and measuring areas of choriocapillaris low perfusion in intermediate, non-neovascular age-related macular degeneration
Optical coherence tomography angiography (OCTA)1,2 is an imaging modality that allows depth-resolved and noninvasive imaging of the retinal and choroidal flow.3 – 7 OCTA algorithms use the variation of optical coherence tomography (OCT) signal over time to detect blood flow against avascular tissue. Although significantly attenuated by the highly scattering retinal pigment epithelium (RPE), the OCT signal incoming from the choriocapillaris layer is generally enough to retrieve the blood flow information in both spectral domain and swept source OCT. Although the resolution of current OCTA devices is not sufficient to resolve either the true caliber of choroidal capillaries or the minuscule intravascular spaces,8 signal defects such as flow voids are large enough to be detected and measured.5,7
- Open Access
- 12 July 2019
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 6 (04) , 041104-10
Monitoring retinal responses to acute intraocular pressure elevation in rats with visible light optical coherence tomography
Elevated intraocular pressure (IOP) is the best-characterized risk factor for glaucoma, the second leading cause of blindness worldwide,1 and lowering IOP can preserve vision for many glaucoma patients.2 However, despite the success of IOP-lowering drugs,3 the association of IOP with glaucoma and the mechanisms by which elevated IOP damages the retina as well as the optic nerve remain unclear and require further investigation.4
- 12 July 2019
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 6 (04) , 041104-10
Open AccessMonitoring retinal responses to acute intraocular pressure elevation in rats with visible light optical coherence tomography
Elevated intraocular pressure (IOP) is the best-characterized risk factor for glaucoma, the second leading cause of blindness worldwide,1 and lowering IOP can preserve vision for many glaucoma patients.2 However, despite the success of IOP-lowering drugs,3 the association of IOP with glaucoma and the mechanisms by which elevated IOP damages the retina as well as the optic nerve remain unclear and require further investigation.4
- Open Access
- 1 February 2017
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 22 (2) , 026001
Automated three-dimensional registration and volume rebuilding for wide-field angiographic and structural optical coherence tomography
We propose a three-dimensional (3-D) registration method to correct motion artifacts and construct the volume structure for angiographic and structural optical coherence tomography (OCT). This algorithm is particularly suitable for the nonorthogonal wide-field OCT scan acquired by a ultrahigh-speed swept-source system ( A-scan rate). First, the transverse motion artifacts are corrected by the between-frame registration based on en face OCT angiography (OCTA). After A-scan transverse translation between B-frames, the axial motions are corrected based on the rebuilt boundary of inner limiting membrane. Finally, a within-frame registration is performed for local optimization based on cross-sectional OCTA. We evaluated this algorithm on retinal volumes of six normal subjects. The results showed significantly improved retinal smoothness in 3-D-registered structural OCT and image contrast on en face OCTA.- 1 February 2017
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 22 (2) , 026001
Open AccessAutomated three-dimensional registration and volume rebuilding for wide-field angiographic and structural optical coherence tomography
We propose a three-dimensional (3-D) registration method to correct motion artifacts and construct the volume structure for angiographic and structural optical coherence tomography (OCT). This algorithm is particularly suitable for the nonorthogonal wide-field OCT scan acquired by a ultrahigh-speed swept-source system ( A-scan rate). First, the transverse motion artifacts are corrected by the between-frame registration based on en face OCT angiography (OCTA). After A-scan transverse translation between B-frames, the axial motions are corrected based on the rebuilt boundary of inner limiting membrane. Finally, a within-frame registration is performed for local optimization based on cross-sectional OCTA. We evaluated this algorithm on retinal volumes of six normal subjects. The results showed significantly improved retinal smoothness in 3-D-registered structural OCT and image contrast on en face OCTA. - 24 August 2016
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 21 (08) , 086015
Calibration of optical coherence tomography angiography with a microfluidic chip
A microfluidic chip with microchannels ranging from 8 to was used to mimic blood vessels down to the capillary level. Blood flow within the microfluidic channels was analyzed with split-spectrum amplitude-decorrelation angiography (SSADA)-based optical coherence tomography (OCT) angiography. It was found that the SSADA decorrelation value was related to both blood flow speed and channel width. SSADA could differentiate nonflowing blood inside the microfluidic channels from static paper. The SSADA decorrelation value was approximately linear with blood flow velocity up to a threshold of ( over the range of channel widths). Beyond this threshold, it approached a saturation value . was higher for wider channels, and approached a maximum value as the channel width became much larger than the beam focal spot diameter. These results indicate that decorrelation values (flow signal) in capillary networks would be proportional to both flow velocity and vessel caliber but would be capped at a saturation value in larger blood vessels. These findings are useful for interpretation and quantification of clinical OCT angiography results.- 24 August 2016
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 21 (08) , 086015
Calibration of optical coherence tomography angiography with a microfluidic chip
A microfluidic chip with microchannels ranging from 8 to was used to mimic blood vessels down to the capillary level. Blood flow within the microfluidic channels was analyzed with split-spectrum amplitude-decorrelation angiography (SSADA)-based optical coherence tomography (OCT) angiography. It was found that the SSADA decorrelation value was related to both blood flow speed and channel width. SSADA could differentiate nonflowing blood inside the microfluidic channels from static paper. The SSADA decorrelation value was approximately linear with blood flow velocity up to a threshold of ( over the range of channel widths). Beyond this threshold, it approached a saturation value . was higher for wider channels, and approached a maximum value as the channel width became much larger than the beam focal spot diameter. These results indicate that decorrelation values (flow signal) in capillary networks would be proportional to both flow velocity and vessel caliber but would be capped at a saturation value in larger blood vessels. These findings are useful for interpretation and quantification of clinical OCT angiography results.- Open Access
- 1 July 2016
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 21 (7) , 076010
Quantification of choroidal neovascularization vessel length using optical coherence tomography angiography
Quantification of choroidal neovascularization (CNV) as visualized by optical coherence tomography angiography (OCTA) may have importance clinically when diagnosing or tracking disease. Here, we present an automated algorithm to quantify the vessel skeleton of CNV as vessel length. Initial segmentation of the CNV on en face angiograms was achieved using saliency-based detection and thresholding. A level set method was then used to refine vessel edges. Finally, a skeleton algorithm was applied to identify vessel centerlines. The algorithm was tested on nine OCTA scans from participants with CNV and comparisons of the algorithm’s output to manual delineation showed good agreement.
- 1 July 2016
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 21 (7) , 076010
Open AccessQuantification of choroidal neovascularization vessel length using optical coherence tomography angiography
Quantification of choroidal neovascularization (CNV) as visualized by optical coherence tomography angiography (OCTA) may have importance clinically when diagnosing or tracking disease. Here, we present an automated algorithm to quantify the vessel skeleton of CNV as vessel length. Initial segmentation of the CNV on en face angiograms was achieved using saliency-based detection and thresholding. A level set method was then used to refine vessel edges. Finally, a skeleton algorithm was applied to identify vessel centerlines. The algorithm was tested on nine OCTA scans from participants with CNV and comparisons of the algorithm’s output to manual delineation showed good agreement.
- Open Access
- 1 December 2015
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 20 (12) , 126002
Imaging the anterior eye with dynamic-focus swept-source optical coherence tomography
A custom-built dynamic-focus swept-source optical coherence tomography (SS-OCT) system with a central wavelength of 1310 nm was used to image the anterior eye from the cornea to the lens. An electrically tunable lens was utilized to dynamically control the positions of focusing planes over the imaging range of 10 mm. The B-scan images were acquired consecutively at the same position but with different focus settings. The B-scan images were then registered and averaged after filtering the out-of-focus regions using a Gaussian window. By fusing images obtained at different depth focus locations, high-resolution and high signal-strength images were obtained over the entire imaging depth. In vivo imaging of human anterior segment was demonstrated. The performance of the system was compared with two commercial OCT systems. The human eye ciliary body was better visualized with the dynamic-focusing SS-OCT system than using the commercial 840 and 1310 nm OCT systems. The sulcus-to-sulcus distance was measured, and the result agreed with that acquired with ultrasound biomicroscopy.
- 1 December 2015
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 20 (12) , 126002
Open AccessImaging the anterior eye with dynamic-focus swept-source optical coherence tomography
A custom-built dynamic-focus swept-source optical coherence tomography (SS-OCT) system with a central wavelength of 1310 nm was used to image the anterior eye from the cornea to the lens. An electrically tunable lens was utilized to dynamically control the positions of focusing planes over the imaging range of 10 mm. The B-scan images were acquired consecutively at the same position but with different focus settings. The B-scan images were then registered and averaged after filtering the out-of-focus regions using a Gaussian window. By fusing images obtained at different depth focus locations, high-resolution and high signal-strength images were obtained over the entire imaging depth. In vivo imaging of human anterior segment was demonstrated. The performance of the system was compared with two commercial OCT systems. The human eye ciliary body was better visualized with the dynamic-focusing SS-OCT system than using the commercial 840 and 1310 nm OCT systems. The sulcus-to-sulcus distance was measured, and the result agreed with that acquired with ultrasound biomicroscopy.
- Open Access
- 1 June 2015
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 20 (6) , 066004
En faceDoppler total retinal blood flow measurement with 70 kHz spectral optical coherence tomography
An automated algorithm was developed for total retinal blood flow (TRBF) using 70-kHz spectral optical coherence tomography (OCT). The OCT was calibrated for the transformation from Doppler shift to speed based on a flow phantom. The TRBF scan pattern contained five repeated volume scans () obtained in 3 s and centered on central retinal vessels in the optic disc. The TRBF was calculated using an en face Doppler technique. For each retinal vein, blood flow was measured at an optimal plane where the calculated flow was maximized. The TRBF was calculated by summing flow in all veins. The algorithm tracked vascular branching so that either root or branch veins are summed, but never both. The TRBF in five repeated volumes were averaged to reduce variation due to cardiac cycle pulsation. Finally, the TRBF was corrected for eye length variation. Twelve healthy eyes and 12 glaucomatous eyes were enrolled to test the algorithm. The TRBF was for healthy control and for glaucomatous participants (). The intravisit repeatability was 8.6% for healthy controls and 8.4% for glaucoma participants. The proposed automated method provided repeatable TRBF measurement.- 1 June 2015
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 20 (6) , 066004
Open AccessEn faceDoppler total retinal blood flow measurement with 70 kHz spectral optical coherence tomography
An automated algorithm was developed for total retinal blood flow (TRBF) using 70-kHz spectral optical coherence tomography (OCT). The OCT was calibrated for the transformation from Doppler shift to speed based on a flow phantom. The TRBF scan pattern contained five repeated volume scans () obtained in 3 s and centered on central retinal vessels in the optic disc. The TRBF was calculated using an en face Doppler technique. For each retinal vein, blood flow was measured at an optimal plane where the calculated flow was maximized. The TRBF was calculated by summing flow in all veins. The algorithm tracked vascular branching so that either root or branch veins are summed, but never both. The TRBF in five repeated volumes were averaged to reduce variation due to cardiac cycle pulsation. Finally, the TRBF was corrected for eye length variation. Twelve healthy eyes and 12 glaucomatous eyes were enrolled to test the algorithm. The TRBF was for healthy control and for glaucomatous participants (). The intravisit repeatability was 8.6% for healthy controls and 8.4% for glaucoma participants. The proposed automated method provided repeatable TRBF measurement. - Open Access
- 1 January 2008
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 13 (6) , 064003-9
Retinal blood flow measurement by circumpapillary Fourier domain Doppler optical coherence tomography
Optical coherence tomography (OCT)1 provides high-resolution cross-sectional imaging2, 3, 4, 5, 6 and is commonly used in the diagnosis and management of retinal diseases7, 8, 9 and glaucoma.10, 11 In addition to obtaining morphological images, OCT can also detect a Doppler shift of reflected light, which provides information about flow and movement.12, 13, 14 Several investigators have studied the visualization of blood flow and flow dynamics using Doppler OCT,15, 16, 17, 18, 19 but the measurement of the total flow velocity and volume requires additional information about the incident angle between the OCT probe beam and the blood vessel. This information is not available within a single cross-sectional OCT image. Determination of the incident angle requires three-dimensional (3-D) imaging of the blood vessel using more than one cross-sectional scan. Measurement of flow in branch retinal vessels in vivo has recently been accomplished using Doppler Fourier domain OCT (FD-OCT).20, 21 Phantom flow measurements showed22 that the difference between the measured flow and actual flow is less than 10%. However, sequentially imaging each retinal blood vessel is time-consuming and not a practical way of measuring the total retinal perfusion in a clinical setting. It is desirable to measure the total retinal blood flow in a single scan. Three-dimensional circular scan imaging has been proposed as a method for measuring retinal blood flow.23 However, 3-D imaging of the peripapillary area requires many seconds and cardiac cycles, and the measurement of several flow values within a cardiac cycle was demonstrated for an arc scan across only two vessels.23
- 1 January 2008
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 13 (6) , 064003-9
Open AccessRetinal blood flow measurement by circumpapillary Fourier domain Doppler optical coherence tomography
Optical coherence tomography (OCT)1 provides high-resolution cross-sectional imaging2, 3, 4, 5, 6 and is commonly used in the diagnosis and management of retinal diseases7, 8, 9 and glaucoma.10, 11 In addition to obtaining morphological images, OCT can also detect a Doppler shift of reflected light, which provides information about flow and movement.12, 13, 14 Several investigators have studied the visualization of blood flow and flow dynamics using Doppler OCT,15, 16, 17, 18, 19 but the measurement of the total flow velocity and volume requires additional information about the incident angle between the OCT probe beam and the blood vessel. This information is not available within a single cross-sectional OCT image. Determination of the incident angle requires three-dimensional (3-D) imaging of the blood vessel using more than one cross-sectional scan. Measurement of flow in branch retinal vessels in vivo has recently been accomplished using Doppler Fourier domain OCT (FD-OCT).20, 21 Phantom flow measurements showed22 that the difference between the measured flow and actual flow is less than 10%. However, sequentially imaging each retinal blood vessel is time-consuming and not a practical way of measuring the total retinal perfusion in a clinical setting. It is desirable to measure the total retinal blood flow in a single scan. Three-dimensional circular scan imaging has been proposed as a method for measuring retinal blood flow.23 However, 3-D imaging of the peripapillary area requires many seconds and cardiac cycles, and the measurement of several flow values within a cardiac cycle was demonstrated for an arc scan across only two vessels.23
- Open Access
- 1 January 2007
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 12 (4) , 041215-041215-8
In vivo total retinal blood flow measurement by Fourier domain Doppler optical coherence tomography
There is considerable interest in new methods for the assessment of retinal blood flow for the diagnosis of eye diseases. We present in vivo normal human volumetric retinal flow measurement using Fourier domain Doppler optical coherence tomography. We used a dual-plane scanning pattern to determine the angle between the blood flow and the scanning beam in order to measure total flow velocity. Volumetric flow in each blood vessel around the optic nerve head was integrated in one cardiac cycle in each measurement. Measurements were performed in the right eye of one human subject. The measured venous flow velocity ranged from to . The arterial flow velocity ranged from to . The total retinal venous and arterial flow both added up to approximately . We believe this is the first demonstration of total retinal blood flow measurement using the OCT technique.- 1 January 2007
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 12 (4) , 041215-041215-8
Open AccessIn vivo total retinal blood flow measurement by Fourier domain Doppler optical coherence tomography
There is considerable interest in new methods for the assessment of retinal blood flow for the diagnosis of eye diseases. We present in vivo normal human volumetric retinal flow measurement using Fourier domain Doppler optical coherence tomography. We used a dual-plane scanning pattern to determine the angle between the blood flow and the scanning beam in order to measure total flow velocity. Volumetric flow in each blood vessel around the optic nerve head was integrated in one cardiac cycle in each measurement. Measurements were performed in the right eye of one human subject. The measured venous flow velocity ranged from to . The arterial flow velocity ranged from to . The total retinal venous and arterial flow both added up to approximately . We believe this is the first demonstration of total retinal blood flow measurement using the OCT technique.