Automated three-dimensional registration and volume rebuilding for wide-field angiographic and structural optical coherence tomography
Open Access
- 1 February 2017
- journal article
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 22 (2) , 026001
Abstract
We propose a three-dimensional (3-D) registration method to correct motion artifacts and construct the volume structure for angiographic and structural optical coherence tomography (OCT). This algorithm is particularly suitable for the nonorthogonal wide-field OCT scan acquired by a ultrahigh-speed swept-source system ( A-scan rate). First, the transverse motion artifacts are corrected by the between-frame registration based on en face OCT angiography (OCTA). After A-scan transverse translation between B-frames, the axial motions are corrected based on the rebuilt boundary of inner limiting membrane. Finally, a within-frame registration is performed for local optimization based on cross-sectional OCTA. We evaluated this algorithm on retinal volumes of six normal subjects. The results showed significantly improved retinal smoothness in 3-D-registered structural OCT and image contrast on en face OCTA.
Keywords
Funding Information
- National Institutes of Health (R01 EY023285)
- Oregon Health and Science Foundation (OHSU), National Institutes of Health (R01 EY023285)
- National Eye Institute (R01 EY023285)
- National Institutes of Health (DP3 DK104397)
- National Institutes of Health (DP3 DK104397)
- Oregon Health and Science Foundation (OHSU), National Institutes of Health (DP3 DK104397)
- National Eye Institute (DP3 DK104397)
- National Institutes of Health (R01 EY024544)
- National Institutes of Health (R01 EY024544)
- Oregon Health and Science Foundation (OHSU), National Institutes of Health (R01 EY024544)
- National Eye Institute (R01 EY024544)
- National Institutes of Health (P30 EY010572)
- National Institutes of Health (P30 EY010572)
- Oregon Health and Science Foundation (OHSU), National Institutes of Health (P30 EY010572)
- National Eye Institute (P30 EY010572)
- National Natural Science Foundation of China (61471226)
- Oregon Health Science University (OHSU) foundation NSFC (61471226)
- Natural Science Foundation for Distinguished Young Scholars of Shandong Province (JQ201516)
This publication has 29 references indexed in Scilit:
- Coherence revival multiplexed, buffered swept source optical coherence tomography: 400 kHz imaging with a 100 kHz sourceOptics Letters, 2014
- Split-spectrum amplitude-decorrelation angiography with optical coherence tomographyOptics Express, 2012
- Intensity-based modified Doppler variance algorithm: application to phase instable and phase stable optical coherence tomography systemsOptics Express, 2011
- Eigendecomposition-Based Clutter Filtering Technique for Optical MicroangiographyIEEE Transactions on Biomedical Engineering, 2011
- In vivo volumetric imaging of human retinal circulation with phase-variance optical coherence tomographyBiomedical Optics Express, 2011
- Ultrahigh speed Spectral / Fourier domain OCT ophthalmic imaging at 70,000 to 312,500 axial scans per secondOptics Express, 2008
- Speckle variance detection of microvasculature using swept-source optical coherence tomographyOptics Letters, 2008
- Three dimensional optical angiographyOptics Express, 2007
- Optical coherence angiographyOptics Express, 2006
- Optical Coherence TomographyScience, 1991