Xin Qi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Xin Qi has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Andrew M.. Rollins
Case Western Reserve University, Department of Biomedical Engineering, Cleveland, Ohio, United States
2 shared publications Michael V. Sivak
Case Western Reserve University, Department of Medicine, Cleveland, Ohio 44106
2 shared publicationsDavid J. Foran
Rutgers Cancer Institute of New Jersey, Department of Pathology and Laboratory Medicine, New Brunswi
1 shared publicationEric A. Singer
Rutgers Cancer Institute of New Jersey, Section of Urologic Oncology, New Brunswick, New Jersey
1 shared publicationEvita Sadimin
Rutgers Cancer Institute of New Jersey, Department of Pathology and Laboratory Medicine, New Brunswi
1 shared publicationGerard Isenberg
Case Western Reserve University, Department of Medicine, Cleveland, Ohio 44106
1 shared publication
Latest Publications
- Open Access
- 15 November 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 5 (04) , 047501-9
Recurrence analysis on prostate cancer patients with Gleason score 7 using integrated histopathology whole-slide images and genomic data through deep neural networks
Prostate cancer remains the most common noncutaneous malignant tumor in the Western world accounting for approximately one in five of newly diagnosed tumors in men and resulting in an estimated 29,430 deaths in 2018.1 In the United States, approximately one in seven men will be diagnosed with this disease.1 Based on Gleason score, prostate specific antigen (PSA) value, tumor stage, age, and race, patients with prostate cancer are stratified into low-, intermediate-, and high-risk groups.2,3
- 15 November 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 5 (04) , 047501-9
Open AccessRecurrence analysis on prostate cancer patients with Gleason score 7 using integrated histopathology whole-slide images and genomic data through deep neural networks
Prostate cancer remains the most common noncutaneous malignant tumor in the Western world accounting for approximately one in five of newly diagnosed tumors in men and resulting in an estimated 29,430 deaths in 2018.1 In the United States, approximately one in seven men will be diagnosed with this disease.1 Based on Gleason score, prostate specific antigen (PSA) value, tumor stage, age, and race, patients with prostate cancer are stratified into low-, intermediate-, and high-risk groups.2,3
- 1 January 2008
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 13 (5) , 054055-054055-11
Automated quantification of colonic crypt morphology using integrated microscopy and optical coherence tomography
Colonic crypt morphological patterns have shown a close correlation with histopathological diagnosis. Imaging technologies such as high-magnification chromoendoscopy and endoscopic optical coherence tomography (OCT) are capable of visualizing crypt morphology in vivo. We have imaged colonic tissue in vitro to simulate high-magnification chromoendoscopy and endoscopic OCT and demonstrate quantification of morphological features of colonic crypts using automated image analysis. 2-D microscopic images with methylene blue staining and correlated 3-D OCT volumes were segmented using marker-based watershed segmentation. 2-D and 3-D crypt morphological features were quantified. The accuracy of segmentation was validated, and measured features are in agreement with known crypt morphology. This work can enable studies to determine the clinical utility of high-magnification chromoendoscopy and endoscopic OCT, as well as studies to evaluate crypt morphology as a biomarker for colonic disease progression.
- 1 January 2008
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 13 (5) , 054055-054055-11
Automated quantification of colonic crypt morphology using integrated microscopy and optical coherence tomography
Colonic crypt morphological patterns have shown a close correlation with histopathological diagnosis. Imaging technologies such as high-magnification chromoendoscopy and endoscopic optical coherence tomography (OCT) are capable of visualizing crypt morphology in vivo. We have imaged colonic tissue in vitro to simulate high-magnification chromoendoscopy and endoscopic OCT and demonstrate quantification of morphological features of colonic crypts using automated image analysis. 2-D microscopic images with methylene blue staining and correlated 3-D OCT volumes were segmented using marker-based watershed segmentation. 2-D and 3-D crypt morphological features were quantified. The accuracy of segmentation was validated, and measured features are in agreement with known crypt morphology. This work can enable studies to determine the clinical utility of high-magnification chromoendoscopy and endoscopic OCT, as well as studies to evaluate crypt morphology as a biomarker for colonic disease progression.
- Open Access
- 1 January 2006
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 11 (4) , 044010-044010-10
Computer-aided diagnosis of dysplasia in Barrett’s esophagus using endoscopic optical coherence tomography
Barrett’s esophagus (BE) and associated adenocarcinoma have emerged as a major health care problem over the last two decades. Because of the widespread use of endoscopy, BE is being recognized increasingly in all Western countries. In clinical trials of endoscopic optical coherence tomography (EOCT), we defined certain image features that appear to be characteristic of precancerous (dysplastic) mucosa: decreased scattering and disorganization in the microscopic morphology. The objective of the present work is to develop computer-aided diagnosis (CAD) algorithms that aid the detection of dysplasia in BE. The image dataset used in the present study was derived from a total of 405 EOCT images (13 patients) that were paired with highly correlated histologic sections of corresponding biopsies. Of these, 106 images were included in the study. The CAD algorithm used was based on a standard texture analysis method (center-symmetric auto-correlation). Using histology as the reference standard, this CAD algorithm had a sensitivity of 82%, specificity of 74%, and accuracy of 83%. CAD has the potential to quantify and standardize the diagnosis of dysplasia and allows high throughput image evaluation for EOCT screening applications. With further refinements, CAD could also improve the accuracy of EOCT identification of dysplasia in BE.
- 1 January 2006
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 11 (4) , 044010-044010-10
Open AccessComputer-aided diagnosis of dysplasia in Barrett’s esophagus using endoscopic optical coherence tomography
Barrett’s esophagus (BE) and associated adenocarcinoma have emerged as a major health care problem over the last two decades. Because of the widespread use of endoscopy, BE is being recognized increasingly in all Western countries. In clinical trials of endoscopic optical coherence tomography (EOCT), we defined certain image features that appear to be characteristic of precancerous (dysplastic) mucosa: decreased scattering and disorganization in the microscopic morphology. The objective of the present work is to develop computer-aided diagnosis (CAD) algorithms that aid the detection of dysplasia in BE. The image dataset used in the present study was derived from a total of 405 EOCT images (13 patients) that were paired with highly correlated histologic sections of corresponding biopsies. Of these, 106 images were included in the study. The CAD algorithm used was based on a standard texture analysis method (center-symmetric auto-correlation). Using histology as the reference standard, this CAD algorithm had a sensitivity of 82%, specificity of 74%, and accuracy of 83%. CAD has the potential to quantify and standardize the diagnosis of dysplasia and allows high throughput image evaluation for EOCT screening applications. With further refinements, CAD could also improve the accuracy of EOCT identification of dysplasia in BE.