YLYan Liang

Yan Liang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yan Liang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:

  • Chen Cui

    Department of Magnetic Resonance Imaging, Imaging Center, Fuwai Hospital,State Key Laboratory of Cardiovascular Disease, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China

    1 shared publication
  • Daniel Giese

    Research & Clinical Translation, Magnetic Resonance Siemens Healthineers AG Erlangen Germany

    1 shared publication
  • Gang Yin

    Department of Magnetic Resonance Imaging, Imaging Center, Fuwai Hospital,State Key Laboratory of Cardiovascular Disease, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China

    1 shared publication
  • Jing An

    Siemens Shenzhen Magnetic Resonance Ltd. Shenzhen China

    1 shared publication
  • Kai Yang

    Department of Radiology, Fuwai Hospital, National Center for Cardiovascular Diseases, State Key Laboratory of Cardiovascular Disease, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China

    1 shared publication
  • Lin Chen

    Imaging Center, Fuwai Hospital and National Center for Cardiovascular Diseases Peking Union Medical College and Chinese Academy of Medical Sciences Beijing China

    1 shared publication

Latest Publications

  • Compressed Sensing–Accelerated Cartesian Real‐Time Phase Contrast MRI With Shared Velocity Encoding: A Clinical Performance Evaluation

    by Gang Yin, Yan Liang, Mi Li, Xinling Yang, Lin Chen, Kai Yang, Chen Cui, Xiuyu Chen, Jing An, Giese Daniel, et al.

    Background: Conventional segmented phase contrast (PC) MRI is the clinical reference standard for cardiovascular hemodynamic quantification, but prolonged acquisition times, mandatory breath‐holding, and susceptibility to arrhythmia limit its utility in vulnerable populations. Purpose: To validate the clinical performance of compressed sensing–accelerated real‐time (CSRT) PC MRI with shared velocity encoding (SVE) for fast, free‐breathing cardiac flow assessment. Study Type: Prospective. Population: 63 patients (46 male/17 female, mean age 51.5 ± 15.1 years) with diverse cardiac disease. Field Strength/Sequence: 3.0 T; single‐shot RF‐spoiled gradient echo sequence with SVE (free‐breathing CSRT PC MRI) and velocity encoded segmented gradient echo sequence (breath‐hold routine segmented (RS) PC MRI). Assessment: Hemodynamic parameters—peak velocity, peak flow rate, net flow rate, and peak mean velocity—were measured at the sinotubular junction plane for both CSRT and RS datasets. Scan time of the two sequences was recorded. Statistical Tests: Pearson/Spearman correlation analysis, intraclass correlation coefficient (ICC), Bland–Altman analysis, paired t ‐test/Wilcoxon test. A p value < 0.05 was considered significant. Results: RS acquisition time was 16.0 ± 2.3 s; total imaging time including breath‐hold instructions was 26.0 ± 2.3 s, whereas CSRT acquisition time was 10.0 s, yielding a statistically significant difference in scan duration. All hemodynamic parameters demonstrated strong significant correlation between CSRT PC and RS PC MRI ( r ≥ 0.89) and good‐to‐excellent inter‐method agreement (ICC ≥ 0.87). CSRT PC yielded significantly lower values for peak velocity (bias = −16.72 ± 11.48 cm/s [−13.31% ± 9.68%]), peak flow rate (bias = −36.28 ± 35.06 mL/s [−9.18% ± 8.98%]), and peak mean velocity (bias = −6.49 ± 7.06 cm/s [−11.02% ± 13.14%]) relative to the RS, but net flow rate was not significantly different between methods (bias = 0.15% ± 0.60 L/min [4.16% ± 17.28%, p = 0.058]). Data Conclusions: CSRT PC provided satisfactory agreement with conventional RS PC while shortening scan time and enabling free‐breathing acquisition. Evidence Level: 1. Technical Efficacy: Stage 1.