Compressed Sensing–Accelerated Cartesian Real‐Time Phase Contrast MRI With Shared Velocity Encoding: A Clinical Performance Evaluation
- 27 September 2026
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
Abstract
Background: Conventional segmented phase contrast (PC) MRI is the clinical reference standard for cardiovascular hemodynamic quantification, but prolonged acquisition times, mandatory breath‐holding, and susceptibility to arrhythmia limit its utility in vulnerable populations. Purpose: To validate the clinical performance of compressed sensing–accelerated real‐time (CSRT) PC MRI with shared velocity encoding (SVE) for fast, free‐breathing cardiac flow assessment. Study Type: Prospective. Population: 63 patients (46 male/17 female, mean age 51.5 ± 15.1 years) with diverse cardiac disease. Field Strength/Sequence: 3.0 T; single‐shot RF‐spoiled gradient echo sequence with SVE (free‐breathing CSRT PC MRI) and velocity encoded segmented gradient echo sequence (breath‐hold routine segmented (RS) PC MRI). Assessment: Hemodynamic parameters—peak velocity, peak flow rate, net flow rate, and peak mean velocity—were measured at the sinotubular junction plane for both CSRT and RS datasets. Scan time of the two sequences was recorded. Statistical Tests: Pearson/Spearman correlation analysis, intraclass correlation coefficient (ICC), Bland–Altman analysis, paired t ‐test/Wilcoxon test. A p value < 0.05 was considered significant. Results: RS acquisition time was 16.0 ± 2.3 s; total imaging time including breath‐hold instructions was 26.0 ± 2.3 s, whereas CSRT acquisition time was 10.0 s, yielding a statistically significant difference in scan duration. All hemodynamic parameters demonstrated strong significant correlation between CSRT PC and RS PC MRI ( r ≥ 0.89) and good‐to‐excellent inter‐method agreement (ICC ≥ 0.87). CSRT PC yielded significantly lower values for peak velocity (bias = −16.72 ± 11.48 cm/s [−13.31% ± 9.68%]), peak flow rate (bias = −36.28 ± 35.06 mL/s [−9.18% ± 8.98%]), and peak mean velocity (bias = −6.49 ± 7.06 cm/s [−11.02% ± 13.14%]) relative to the RS, but net flow rate was not significantly different between methods (bias = 0.15% ± 0.60 L/min [4.16% ± 17.28%, p = 0.058]). Data Conclusions: CSRT PC provided satisfactory agreement with conventional RS PC while shortening scan time and enabling free‐breathing acquisition. Evidence Level: 1. Technical Efficacy: Stage 1.Keywords
Funding Information
- National Natural Science Foundation of China (82471973)
- Natural Science Foundation of Beijing Municipality (7242110)
This publication has 25 references indexed in Scilit:
- Evaluation of Real‐Time Cardiovascular Flow MRI Using Compressed Sensing in a Phantom and in Patients With Valvular Disease or ArrhythmiaJournal of Magnetic Resonance Imaging, 2025
- Highly accelerated free-breathing real-time 2D flow imaging using compressed sensing and shared velocity encodingEuropean Radiology, 2023
- Clinical Applications of Four-Dimensional Flow MRIMagnetic Resonance Imaging Clinics of North America, 2023
- Real-time phase contrast MRI versus conventional phase contrast MRI at different spatial resolutions and velocity encodingsClinical Imaging, 2022
- Highly accelerated free‐breathing real‐time phase contrast cardiovascular MRI via complex‐difference deep learningMagnetic Resonance in Medicine, 2021
- Highly accelerated, real‐time phase‐contrast MRI using radial k‐space sampling and GROG‐GRASP reconstruction: a feasibility study in pediatric patients with congenital heart diseaseNMR in Biomedicine, 2020
- A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability ResearchJournal of Chiropractic Medicine, 2016
- Real-time phase contrast magnetic resonance imaging for assessment of haemodynamics: from phantom to patientsEuropean Radiology, 2015
- Advances in real-time phase-contrast flow MRI using asymmetric radial gradient echoesMagnetic Resonance in Medicine, 2015
- Shared velocity encoding: A method to improve the temporal resolution of phase‐contrast velocity measurementsMagnetic Resonance in Medicine, 2011