Xingcheng Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xingcheng Yu has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Bo Zhang
School of Electrical Engineering, Shenyang University of Technology, Shenyang 110870, China
2 shared publications - Jiaxuan Liang
College of Computer Science and Technology, Shenyang Institute of Engineering, Shenyang 110136, China
1 shared publication - Junqi Yang
School of Computer Science and Technology, Shenyang Institute of Engineering, Shenyang 110136, China
1 shared publication - Qidan Zhang
College of Computer Science and Technology, Shenyang Institute of Engineering, Shenyang 110136, China
1 shared publication - Sheng Ma
School of Computer Science and Technology, Shenyang Institute of Engineering, Shenyang 110136, China
1 shared publication - Weitao Meng
School of Computer Science and Technology, Shenyang Institute of Engineering, Shenyang 110136, China
1 shared publication
Latest Publications
- Open Access
- 5 November 2026
- Published by MDPI AG in Electronics
- Vol. 15 (21) , 5127
An Analytical Transient Model for Three-Phase Transformer Reclosing Considering Hysteresis Residual Magnetism and Recovery Control of Cascading Failures in Cyber-Physical Power Systems
In cyber-physical power systems (CPPS), the inrush current generated during transformer reclosing can easily cause misjudgment of protection devices and thus serves as an important trigger for cascading failure propagation. Existing studies mostly rely on black-box electromagnetic transient simulations or simplified magnetization models, lacking analytical approaches that account for hysteresis and residual magnetism, and therefore fail to accurately characterize the coupling mechanism between physical transients and information-layer dynamics. To address this issue, an analytical transient model for three-phase transformer reclosing is established based on the Jiles–Atherton theory, in which the hysteresis loop and residual magnetism are embedded into the electromagnetic transient process as a differential–algebraic equation (DAE) set, and the semi-analytical dependence of the inrush peak, harmonic characteristics, and decay law on the residual flux and closing angle is derived. On this basis, an inrush-feature-driven probability model of protection misjudgment is constructed, a CPPS cascading failure propagation model incorporating physical–information state transitions is developed, and an adaptive reclosing recovery control strategy based on the node fault-state reachability is proposed. Simulations on the IEEE 39-bus system show that the proposed model accurately reproduces the quantitative influence of hysteresis residual magnetism on inrush characteristics (the peak error is within 10% compared with measured/detailed simulation results), and the proposed control strategy reduces the misjudgment rate per reclosing operation from 6.78% to 1.18% (a reduction of approximately 83%) and the post-recovery load loss from 0.182% to 0.001%, compared with the conventional reclosing scheme, significantly improving the resilience and recovery efficiency of the CPPS.
- 5 November 2026
- Published by MDPI AG in Electronics
- Vol. 15 (21) , 5127
Open AccessAn Analytical Transient Model for Three-Phase Transformer Reclosing Considering Hysteresis Residual Magnetism and Recovery Control of Cascading Failures in Cyber-Physical Power Systems
In cyber-physical power systems (CPPS), the inrush current generated during transformer reclosing can easily cause misjudgment of protection devices and thus serves as an important trigger for cascading failure propagation. Existing studies mostly rely on black-box electromagnetic transient simulations or simplified magnetization models, lacking analytical approaches that account for hysteresis and residual magnetism, and therefore fail to accurately characterize the coupling mechanism between physical transients and information-layer dynamics. To address this issue, an analytical transient model for three-phase transformer reclosing is established based on the Jiles–Atherton theory, in which the hysteresis loop and residual magnetism are embedded into the electromagnetic transient process as a differential–algebraic equation (DAE) set, and the semi-analytical dependence of the inrush peak, harmonic characteristics, and decay law on the residual flux and closing angle is derived. On this basis, an inrush-feature-driven probability model of protection misjudgment is constructed, a CPPS cascading failure propagation model incorporating physical–information state transitions is developed, and an adaptive reclosing recovery control strategy based on the node fault-state reachability is proposed. Simulations on the IEEE 39-bus system show that the proposed model accurately reproduces the quantitative influence of hysteresis residual magnetism on inrush characteristics (the peak error is within 10% compared with measured/detailed simulation results), and the proposed control strategy reduces the misjudgment rate per reclosing operation from 6.78% to 1.18% (a reduction of approximately 83%) and the post-recovery load loss from 0.182% to 0.001%, compared with the conventional reclosing scheme, significantly improving the resilience and recovery efficiency of the CPPS.
- Open Access
- 23 October 2026
- Published by MDPI AG in Electronics
- Vol. 15 (21) , 4912
False Data Injection Screening for Temperature Monitoring of Distribution Transformers Based on Lightweight Blockchain and Winding Structural Fingerprinting
Temperature monitoring underpins the protection and condition assessment of distribution transformers, whose dominant failure mode is overheating-induced insulation aging; this makes temperature data the prime target of false data injection (FDI) attacks. Because FDI acts on data rather than on the physical asset, this paper exploits the winding structure, which data injection cannot alter, as a physical trust anchor: a structural fingerprint is extracted from port measurements through frequency-dependent harmonic resistance; the systematic temperature-response differences between wire-wound and foil-wound windings build an independent physical cross-check channel; and a lightweight PBFT consortium blockchain notarizes the fingerprint baseline so that a compromised local database cannot rewrite it. Structural, physical, and command consistency indicators classify input-, output-, and model-parameter-tampering attacks. Finite-element simulations and 100-round randomized attack tests show a 9.6% structural temperature deviation that provides a clear physical screening margin: the three attack types are detected and classified within 4 s at a 100% detection rate (95% CI [96.4, 100]%) and a 0.3% false-alarm rate, while a stealthy ramp injection is caught after about 105 min and a sub-threshold constant offset is caught by trend monitoring in about 4 h. A seven-node chain implemented with real ECDSA-secp256k1 signatures achieves 0.42–0.90 s finality per notarization, 8.9–19.0 notarizations/s, and a 0.47 s view change, two orders of magnitude above the field notarization demand, meeting lightweight deployment requirements.
- 23 October 2026
- Published by MDPI AG in Electronics
- Vol. 15 (21) , 4912
Open AccessFalse Data Injection Screening for Temperature Monitoring of Distribution Transformers Based on Lightweight Blockchain and Winding Structural Fingerprinting
Temperature monitoring underpins the protection and condition assessment of distribution transformers, whose dominant failure mode is overheating-induced insulation aging; this makes temperature data the prime target of false data injection (FDI) attacks. Because FDI acts on data rather than on the physical asset, this paper exploits the winding structure, which data injection cannot alter, as a physical trust anchor: a structural fingerprint is extracted from port measurements through frequency-dependent harmonic resistance; the systematic temperature-response differences between wire-wound and foil-wound windings build an independent physical cross-check channel; and a lightweight PBFT consortium blockchain notarizes the fingerprint baseline so that a compromised local database cannot rewrite it. Structural, physical, and command consistency indicators classify input-, output-, and model-parameter-tampering attacks. Finite-element simulations and 100-round randomized attack tests show a 9.6% structural temperature deviation that provides a clear physical screening margin: the three attack types are detected and classified within 4 s at a 100% detection rate (95% CI [96.4, 100]%) and a 0.3% false-alarm rate, while a stealthy ramp injection is caught after about 105 min and a sub-threshold constant offset is caught by trend monitoring in about 4 h. A seven-node chain implemented with real ECDSA-secp256k1 signatures achieves 0.42–0.90 s finality per notarization, 8.9–19.0 notarizations/s, and a 0.47 s view change, two orders of magnitude above the field notarization demand, meeting lightweight deployment requirements.