Sunghyun Kim
Research Subjects
Sunghyun Kim has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- B. E. Kane
Laboratory for Physical Sciences 1 , 8050 Greenmead Dr., College Park, Maryland 20740
1 shared publication - Joyce E. Coppock
University of Maryland
1 shared publication - Sarah Westgate
University of Maryland 3 , College Park, Maryland 20742
1 shared publication
Latest Publications
- Open Access
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Collection, characterization, and precision measurement of levitated charged nanoparticles
We describe apparatus and experimental procedures for high stability precision measurements of levitated nanoscale particles confined in an ion trap in high vacuum. We discuss methods for particle generation and collection using electrospray emission, rapid characterization by direct imaging of thermal motion, and transfer of the particle from the trap where it is collected to a separate analysis trap in order to achieve better vacuum and lower noise. In the analysis trap at high vacuum (pressure p ≃ 10−8 Torr), we employ thermostatic control of the trapped particle oscillation amplitudes, allowing long-term, precision measurements of oscillation frequencies, from which the charge to mass ratio (Q/M) can be deduced. Under these conditions, we achieve Q/M measurement precision approaching 10−5. This sensitivity will enable, for example, investigations of the surface chemistry of μm-scale levitated materials in ultra-high vacuum environments.
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Open AccessCollection, characterization, and precision measurement of levitated charged nanoparticles
We describe apparatus and experimental procedures for high stability precision measurements of levitated nanoscale particles confined in an ion trap in high vacuum. We discuss methods for particle generation and collection using electrospray emission, rapid characterization by direct imaging of thermal motion, and transfer of the particle from the trap where it is collected to a separate analysis trap in order to achieve better vacuum and lower noise. In the analysis trap at high vacuum (pressure p ≃ 10−8 Torr), we employ thermostatic control of the trapped particle oscillation amplitudes, allowing long-term, precision measurements of oscillation frequencies, from which the charge to mass ratio (Q/M) can be deduced. Under these conditions, we achieve Q/M measurement precision approaching 10−5. This sensitivity will enable, for example, investigations of the surface chemistry of μm-scale levitated materials in ultra-high vacuum environments.