Latest Publications

  • Open Access

    The effect of magnetic resonance image slice thickness and voxel geometry on digital dental implant planning: an in vitro study

    by Hian Parize, Fábio Munhoz, Carlos Cordeiro, Norbert Meier, Johannes Kleinheinz, Dalva Cruz Laganá, Newton Sesma, Lauren Bohner

    Objectives: To evaluate the effect of magnetic resonance imaging (MRI) slice thickness and voxel geometry on digital dental implant planning compared to cone-beam computed tomography (CBCT). Methods: Edentulous phantoms were scanned using CBCT and two MRI protocols: anisotropic and isotropic. Two calibrated examiners digitally planned the position of four implants for each sample ( n = 8) per exam (CBCT, anisotropic and isotropic). Diagnostic accuracy was assessed using implant angular deviation and linear measurements. Image quality was evaluated using a questionnaire regarding visualization of anatomical structures. Cost-to-planning-time ratio was assessed by exam costs per minute of planning. The Friedman and Wilcoxon tests were used to evaluate differences in diagnostic accuracy, planning time, and cost-to-planning-time ratio. Image quality ratings on a 5-point scale were classified as non-valid (≤ 2) or valid (≥ 3) for clinical use. Reliability was assessed by percentage agreement, and differences were evaluated using the chi-square test. Results: A total of 96 implants were planned, with 32 in each exam. No significant differences were observed between exams for angular deviation ( p > 0.197), linear measurements ( p > 0.305), image quality ( p > 0.132), or planning time ( p = 0.093). However, CBCT had lower cost-to-planning-time ratio than anisotropic and isotropic MRI ( p = 0.012), which did not differ from each other ( p = 1.000). Inter-examiner agreement on image quality for anisotropic and isotropic MRI varied widely, with lower ratings for the mandibular nerve canal. Conclusion: No statistically significant differences were detected among the imaging protocols in diagnostic accuracy or image quality under the investigated in vitro conditions.

  • Open Access

    Bone quality assessment around dental implants in cone-beam CT images: effect of rotation mode and metal artefact reduction tool

    by Lauren Bohner, Hian Parize, João Victor Cunha Cordeiro, Natalia Koerich Laureano, Johannes Kleinheinz, Ricardo Armini Caldas, Dorothea Dagassan-Berndt

    Objectives: The purpose of this study was to evaluate how artefacts caused by titanium and zirconia dental implants affect the bone quality assessment in CBCT images. The effect of scan mode and the use of metal artefact reduction (MAR) algorithm on artefacts suppression were taken in consideration. Methods: Titanium and zirconia dental implants were installed in porcine bone samples and scanned with two CBCT devices with adjustments on scan mode and with the use of MAR. The control group consisted of bone sample without implant and scanned with full-rotation scan mode without MAR. Artefacts extension and bone quality around implants were measured by deviation of grey values and bone histomorphometry measurements (trabecular volume fraction, bone specific surface, trabecular thickness, and trabecular separation), respectively. Mean difference among groups was assessed by within ANOVA with Bonferroni correction. Correlation between bone quality measurements acquired in the experimental and control groups was assessed by Spearman correlation test (α = .05). Results: No statistical difference was found for artefacts extension in images acquired by half and full-rotation modes (P = .82). The application of MAR reduced artefacts caused by titanium and zirconia dental implants, showing no statistically significant difference from the control group (titanium: P = .20; zirconia: P = .31). However, there was no correlation between bone quality measurements (P < .05). Conclusions: Bone quality assessment was affected by the presence of artefacts caused by dental implants. Rotation mode did not affect the appearance of artefacts and bone qualitative measurements. MAR was able to decrease artefacts, however, it did not improve the accuracy of bone quality measurements.


  • Effect of Abutment Tooth Geometry On The Accuracy of Fixed Prosthodontics Casts Obtained by Digital and Analog Workflows—In Vitro Study

    by Hian Parize, Ana Paula Macedo, Bruno Frazão Gribel, Lauren Bohner, Mauricio Martins Provinciatti, Valdir Antonio Muglia

    Objective: Physical and digital casts are required for fixed dental prosthesis (FDP) fabrication. However, the effect of abutment tooth geometry on the accuracy of FDP casts obtained by digital and analog workflows remains unclear. This study evaluated the accuracy of obtaining dental casts for veneer and full crowns with digital and analog workflows.Materials and Methods: A typodont model of the maxilla with unprepared teeth and veneer and full crown preparations was digitalized with intraoral scanning (TRIOS 3; 3Shape), digital model (DM) group, and the digital files were exported to two additive manufacturing technologies, resulting in the groups digital light processing (DLP) (Hunter; FlashForge) and polyjet (PLJ) (Eden 500 V; Stratasys). In addition, plaster casts (PCs) were obtained with polyvinyl siloxane (Express XT; 3M ESPE) double impressions and type IV plaster (FujiRock; GC America) as a control group. The sample size per group (n = 6) was defined in the pilot study. The digitization of the typodont and experimental casts was performed with a laboratory scanner (inEos X5; Dentsply Sirona). The measurement deviation (trueness and precision) to the reference model was performed with reverse engineering software (Geomagic Control X 2018; 3D Systems). Two‐way ANOVA was used to assess the effect of manufacturing techniques and abutment tooth geometry on model accuracy (primary outcome). In addition, one‐way ANOVA was used to assess significant differences between manufacturing techniques for complete arches, including abutments and unprepared teeth (secondary outcome). Tukey post hoc tests were used to compare means among groups. All statistical analyses considered a significant level of p ≤ 0.05.Results: Statistically significant interactions were observed between manufacturing technique and abutment tooth geometry, affecting both trueness (p < 0.001) and precision (p < 0.001). For trueness, DM exhibited the lowest RMS values (p < 0.001), PC and DLP showed no significant difference (p = 0.056), and PLJ had significantly higher values than other techniques (p < 0.001), while premolar and molar preparations displayed significantly lower discrepancies compared to other types (p < 0.002). For precision, DM had the lowest values (p < 0.001), with PC also showing low values (p < 0.001), and no significant differences were observed between DLP and PLJ (p = 0.986). Veneer, premolar, and molar crown preparations demonstrated significantly lower RMS compared to anterior crowns.Conclusion: The design of the abutment tooth significantly influenced the trueness and precision of FDP casts obtained by digital and analog workflow. For trueness, DM exhibited the highest accuracy, outperforming PC, DLP, and PLJ and achieving better results with premolar and molar preparations compared to anterior crowns and veneers. For precision, DM was most accurate, followed by PC, DLP, and PLJ, with veneer, premolar, and molar crowns consistently outperforming anterior crowns.


  • Effect of magnetic resonance imaging protocol on decision‐making for positioning of dental implants in edentulous cases

    by Hian Parize, Norbert Meier, Johannes Kleinheinz, Dalva Cruz Laganá, Newton Sesma, Lauren Bohner

    Purpose: This study aimed to assess the influence of magnetic resonance imaging (MRI) protocol on the decision‐making for the positioning of dental implants in edentulous arches in comparison to planning based on cone beam computed tomography (CBCT).Materials and Methods: One phantom was scanned with CBCT and two MRI protocols (T1‐ and T2‐weighted). Two calibrated examiners performed digital implant planning (coDiagnostiX, Dental Wings), considering a digital prosthetic planning and alveolar ridge surface scan. Four implants were planned for each patient dataset, and the angular deviation between the long axis of the implants and the prosthetic planning occlusal plane was measured.Results: Each examiner planned 40 implants, 12 implants with CBCT and 28 implants with MRI (16 with T1 and 12 with T2 images). Significant differences in angle deviation were observed between CBCT, T1, and T2 in the anterior region for both examiners (p = 0.009 for examiner 1 and p = 0.042 for examiner 2). Implants planned with CBCT showed significantly lower angular deviation than those based on the T1 and T2 scans for both examiners (p = 0.028 and p = 0.046 for examiner 1 and p = 0.028 and p = 0.027 for examiner 2). No significant difference in angular deviation was found between T1 and T2 for both examiners (examiner 1: p = 0.600, examiner 2: p = 0.916).Conclusion: Compared to CBCT planning, the MRI protocol influenced decision‐making for anterior dental implants, with angular deviations within acceptable clinical thresholds, but further studies are needed to validate these findings.


  • 3D virtual patient—Magnetically retained printed stackable system for implant guided placement: Case report

    by Camila Sales Jreige, Rafael Gama, Hian Parize, Gokcen Ates, Newton Sesma

    Objective: The aim of this report is to present the complete workflow of 3D virtual patient for planning and performing implant surgery with magnetically retained 3D‐printed stackable guides.Clinical Considerations: A 3D‐printed stackable system was proposed based on bone, dental, and facial references. Initially, a 66‐year‐old male patient was digitalized through photographs, cone beam computed tomography, and intraoral scans (Virtuo Vivo, Straumann). All files were merged to create a 3D virtual patient in the planning software (coDiagnostiX, Straumann). Sequential stackable guides were designed, printed, and cured. Magnets were inserted into connectors, and the interim protheses received color characterization. Four mounted guides were produced for the specific purposes of pin fixation, bone reduction, implant placement, and immediate provisionalization. After surgery and healing period, patient digital data were updated. Final implant positions were compared to planned values and inconsistencies were clinically acceptable. The mean angular deviation was 5.4° (3.2–7.3) and mean 3D discrepancies were of 0.90 mm (0.46–1.12) at the entry point and 1.68 mm (1.00–2.20) at implant apex. Case follow‐up revealed stability, patient's comfort, and no intercurrences.Conclusion: Magnetically retained stackable guides provide treatment accuracy and reduce surgical and prosthetic complications. The projected virtual patient enhances decision‐making and communication between the multidisciplinary team and the patient, while decreases time and costs.Clinical Significance: Bidimensional diagnosis and freehand implant placement have limitations and outcomes often rely on professionals' expertise. Performing facially driven virtual planning improves treatment predictability. This approach promotes function, esthetic harmony, and patient satisfaction. Implant guided surgery and 3D printed prostheses constitute a reproducible digital workflow that can be implemented into clinical practice to optimize dental care.


  • The crown lengthening double guide and the digital Perio analysis

    by Christian Coachman, Konstantinos Valavanis, Fernanda Camargo Silveira, Sergio Kahn, Alexandra Dias Tavares, Eduardo Mahn, Hian Parize, Felipe Miguel P. Saliba

    Objective: This article describes a surgical crown lengthening double guide, which was digitally obtained to improve diagnosis, treatment outcome, and follow‐up.Clinical considerations: The rehabilitation of anterior dental esthetics should involve interdisciplinary and facially driven planning for achieving pleasant long‐term outcomes. Surgical crown lengthening is one of the most common periodontal surgery, which can be assisted by digital tools to improve surgical planning and follow‐up.Conclusion: The double guide for surgical crown lengthening allows the proper management of hard and soft tissues for achieving a predefined goal based on biological requirements and facially driven planning. In addition, the digital quality control allows the follow‐up compared with the pre‐operative condition and planned treatment plan.Clinical significance: The use of digital tools allow the clinician to develop a facially driven planning with proper communication with the team and patient, leading to a shorter, more predictable, and less invasive surgical technique, reducing postoperative inflammation and increasing patient comfort.


  • Loose intra-articular body in the temporomandibular joint: case report of a successful conservative management

    by Yumi Chokyu DEL Rey, Hian Pari̇ze, Christiano Oli̇vei̇ra-Santos, Marina De Godoy Almei̇da

    Loose intra-articular bodies are a rare finding in the temporomandibular joint. Surgical removal of the loose bodies isoften described as the only treatment option; however, it presents possible postoperative complications. The aim of thispaper is to report the successful conservative management of a temporomandibular disorder associated with a singleloose intra-articular body. A 62-year-old woman presented with pain in the right temporomandibular joint andpre-auricular region, limited mouth opening and open-lock episodes. Panoramic radiography and cone-beam computedtomography exams revealed the presence of a single loose body located anterior to the right condyle. Magnetic resonanceimages showed bilateral anterior disc displacement without reduction. A non-invasive approach consisting of an occlusalsplint and low-level laser therapy associated with home-based physical therapy was performed for management ofclinical signs and symptoms. The patient was followed up for 2 years and presented significant pain reduction andimprovement in the range of mandibular movements. The combination of conservative therapies may be an alternativefor surgical intervention to control pain and improve mandibular function in patients with temporomandibulardysfunction associated with a loose body in the temporomandibular joint.


  • Narrow-Diameter Implants in the Anterior Region: A Meta-analysis

    by Hian Parize, Lauren Bohner, Lorena Gama, André Porporatti, Luis Mezzomo, William Martin, Thais Gonçalves

    Hian Nivaldo Parize, Undergraduate student/Lauren Oliveira Lima Bohner, PhD, Researcher/Lorena Tavares Gama, DDS, Graduate student/Andr? Lu?s Porporatti, PhD, Professor/Luis Andr? Mendon?a Mezzomo, PhD, Professor/William Christopher Martin, DMD, MS, FACP, Clinical Professor/Thais Marques Simek Vega Gon?alves, PhD, Professor: Purpose: Implants in the anterior region are challenging, and literature reporting outcomes of narrow-diameter implants (NDIs) in anterior sites is scarce. This systematic review summarized evidence of functional and esthetic performance of anterior single crowns supported by NDIs. Materials and Methods: Ten databases were searched to find studies evaluating anterior single crowns supported by NDIs. Risk of bias was assessed, and random-effects meta-analyses were applied to analyze mean differences in survival, success, and marginal bone level (MBL). The review was registered in the PROSPERO database (CRD42018089886). Results: Twenty-one studies meeting the screening criteria were included for qualitative analysis, and three for meta-analysis. A total of 892 NDIs, placed in 736 patients, were analyzed. Follow-up duration varied from 12 months to 14 years (mean: 40 months), and 16 failures (implant loss) were recorded. Fixed-effect meta-analysis (I2 = 0%) of survival rate revealed a risk difference of 0.02 (95% CI: ?0.03 to 0.08), between NDIs and controls (regular-diameter implants), without differences between groups (P = .39). Success rates ranged from 84.2% to 100% (mean: 95.2%). Random-effects meta-analysis (I2 = 56%) of MBL indicated a mean difference of 0.02 mm (95% CI: ?0.21 to 0.25), without differences between groups (P = .87). Conclusion: Single crowns supported by NDIs are a predictable treatment, since their survival rate and MBL are comparable to those supported by regular-diameter implants. Due to data shortage reporting esthetic outcomes, more studies are needed to evaluate the long-term performance of the single crowns supported by NDIs in the anterior region.


  • Evaluation of cell proliferation in cystic lesions associated with impacted third molars

    by Bubacar Embaló, Hian Nivaldo Parize, Elena Riet Correa Rivero

    The purpose of this study was to evaluate the metabolism and epithelial cell proliferation of odontogenic keratocyst (OKC), dentigerous cyst (DC), and unicystic ameloblastoma (UA) by quantifying the nucleolar organizing regions (AgNORs) and Ki‐67 protein immunoexpression. Forty‐eight cases (16 OKC, 16 DC, and 16 UA) were evaluated retrospectively. The metabolism and epithelial cell proliferation was measured by the Ki‐67 positive cell percentage index and by the mean AgNOR count in each group. The Ki‐67 and AgNOR counts were significantly higher in OKC comparing to the DC and UA (p < .001). Ki‐67 positive cells were observed higher in suprabasal cell layers of OKC with uniform distribution, a few of them were predominantly observed in basal cell layer in DC and UA. The AgNOR count was significantly higher in the OKC basal cell layers and observed throughout the lining epithelium of DC and UA. Ki‐67 and AgNOR reinforced the aggressive character of OKC, presenting high metabolism and cellular proliferation compared to DC and UA, possibly due to its more aggressive clinical behavior and high recurrence rate.Research Highlights: We evidence higher metabolism and epithelial cell proliferation in OKC when compared to UA and DC, supporting its aggressive aspect and its high rate of recurrence. OKC had intense and predominant labeling of Ki‐67 on the suprabasal layer unlike UA and DC.