SJSiyu Jin

Siyu Jin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Siyu Jin has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Absolute Optical Encoder Using a Reference–Incremental Fused Signal

    by Zhaowu Liu, Peng Zeng, Xu Liang, Wenhao Li, Yanxiu Jiang, Siyu Jin, Yujia Sun

    This letter proposes an absolute positioning method for distance encoding by fusing reference signals with incremental signals. Reference marks with extinction characteristics are embedded in a holographic grating with a high line density. When the reading head scans over these reference marks, the corresponding scale signal amplitude is modulated. The distance is encoded through intensity modulation of the scale signal, achieving absolute positioning with a single reading head and a single code track. A fused signal model based on a Gaussian detection beam is established, and the relationship between the modulation depth of the reference signal and both the Gaussian beam diameter and reference mark width is simulated and analyzed. A prototype system is built to validate the proposed model under $150\mu $ m and $250\mu $ m mark widths. An algorithm combining curve fitting, interpolation optimization, and dual-peak averaging is used to identify and extract the reference mark positions. For ten experimental data sets, the repeat positioning accuracy of the mark spacing is $0.15\mu $ m.

  • Frequency Estimation and Noise Reduction in Homodyne Grating Interferometer based on Third-Order Generalized Integrator-Frequency Locked Loop with Damping Ratio Adaptation

    by Weicheng Wang, Siyu Jin, Zhaowu Liu, Xin’gE Qian, Shuai Pi, Wenhao Li, Jun Lin

    A phase-locked loop (PLL)-based subdivision module can provide distance and velocity information to the homodyne grating interferometer integrated with a servo control system. However, the received sinusoidal signal pair from the homodyne grating interferometer is degraded by considerable low-frequency noise, harmonic components, and white noise, limiting displacement measurement accuracy. In this paper, a fast signal filtering method is proposed for homodyne grating interferometer based on the combination of two third-order generalized integrators (TOGIs) and a frequency-locked loop (FLL). FLL is designed with damping ratio adaption to obtain high-accuracy estimation of time-varying frequency of the homodyne grating interferometer signal, while two TOGIs are employed as frequency-adaptive band-pass filters using the FLL estimated frequency as the center frequency. Therefore, the proposed method enables accurate tracking of the fundamental components within the homodyne grating interferometer signals, thereby effectively reducing noise. The performance of the proposed method is evaluated through simulations and physical experiments under various conditions, including frequency step changes, white noise, low-frequency noise, harmonics, and sinusoidal motions covering constant velocity and acceleration regimes. The results demonstrated that the proposed method generally outperformed other methods, namely SOGI-FLL, SOGI-FLLWPF and SOGI-FLL-WIF. This study contributes to enabling more accurate and reliable displacement measurement using homodyne grating interferometers.

  • A Real-Time Determination Method for Homodyne Grating Interferometer Signal Nonlinear Error Based on Duty Cycle Measurement of States

    by Weicheng Wang, Jun Lin, Siyu Jin, Yu Bai, Lin Liu, Zhaowu Liu, Yishu Sun, Wenhao Li

    Nonlinear error is a serious obstruction for increasing the resolution and accuracy of the homodyne grating interferometer. To eliminate the nonlinear error, this paper presents a real-time method to determine the nonlinear error in the homodyne grating interferometer signal. Two thresholds separate the signal into four states, the duty cycle of each state will be measured and used to determine the nonlinear error parameters separately. The method proposed was implemented using MATLAB and an FPGA for the determination process. The simulation and experiment results indicated that the proposed method is easier to achieve with similar accuracy and precision compared with the methods based on the fitting algorithm. The nonlinear error could be reduced to about 37 nm from 79 nm in a 100 μm test, similar to the fitting algorithms.