İsEn Güleç Koçyiğit
Research Subjects
İsEn Güleç Koçyiğit has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Aybüke Karaca Sakallı
Department of Endodontics, Faculty of Dentistry, Ankara Medipol University, Ankara, Turkey
2 shared publications - Bilge Özcan
DentTarz Academy Dental Clinic
2 shared publications - Lena Bal
Department of Restorative Dentistry, Faculty of Dentistry, Ankara Medipol University, 06570 Ankara, Turkey
2 shared publications - Cangül Keskin
Department of Endodontics, Faculty of Dentistry, Ondokuz Mayıs University, Samsun, Türkiye
1 shared publication - Gorkem Liman
GAZİ ÜNİVERSİTESİ, GAZİ EĞİTİM FAKÜLTESİ, FEN BİLİMLERİ BÖLÜMÜ
1 shared publication
Latest Publications
- 27 January 2026
- Published by Ankara Dis Hekimleri Odasi in ADO Klinik Bilimler Dergisi
- Vol. 15 (1) , 24-31
In Vitro Assessment of pH and Surface Contact Angle of Triton as a Novel All-In-One Disinfectant
Introduction: This study compared the pH levels and surface wettability of conventional endodontic irrigants with Triton, a novel all-in-one solution. Sodium hypochlorite (NaOCl), ethylenediaminetetraacetic acid (EDTA), chlorhexidine (CHX), and Triton were tested. Materials and Methods: Each irrigant (10 mL) was stored in glass tubes (n=10). pH was measured with an electronic pH meter on days 1, 2, 5, 7, and 14, with three repeated measurements at each time point. For contact angle analysis, 26 extracted anterior teeth were sectioned, standardized, and exposed to the irrigants. Angles were measured using a goniometer device (SEO Phonix Contact Angle, Republic of Korea). Data were analyzed using repeated-measures ANOVA followed by Bonferroni-adjusted pairwise comparisons (p<0.05). Results: Significant differences were found among irrigants for both pH and contact angle (p<0.05). All solutions showed lower pH values at day 14 compared to day 1 (p<0.05). In the Triton group, values at days 1, 2, and 5 were not significantly different, whereas decreases were observed at days 7 and 14 (p<0.05). CHX (14.73°) and NaOCl (15.82°) demonstrated the lowest contact angles, Triton an intermediate value (19.35°), and EDTA the highest (21.46°). Conclusion: Triton maintained stable pH values during the first week and provided satisfactory dentin wettability, superior to EDTA but lower than CHX and NaOCl. These properties support its potential as a next-generation irrigant that combines multiple functions in a single solution.
- 27 January 2026
- Published by Ankara Dis Hekimleri Odasi in ADO Klinik Bilimler Dergisi
- Vol. 15 (1) , 24-31
In Vitro Assessment of pH and Surface Contact Angle of Triton as a Novel All-In-One Disinfectant
Introduction: This study compared the pH levels and surface wettability of conventional endodontic irrigants with Triton, a novel all-in-one solution. Sodium hypochlorite (NaOCl), ethylenediaminetetraacetic acid (EDTA), chlorhexidine (CHX), and Triton were tested. Materials and Methods: Each irrigant (10 mL) was stored in glass tubes (n=10). pH was measured with an electronic pH meter on days 1, 2, 5, 7, and 14, with three repeated measurements at each time point. For contact angle analysis, 26 extracted anterior teeth were sectioned, standardized, and exposed to the irrigants. Angles were measured using a goniometer device (SEO Phonix Contact Angle, Republic of Korea). Data were analyzed using repeated-measures ANOVA followed by Bonferroni-adjusted pairwise comparisons (p<0.05). Results: Significant differences were found among irrigants for both pH and contact angle (p<0.05). All solutions showed lower pH values at day 14 compared to day 1 (p<0.05). In the Triton group, values at days 1, 2, and 5 were not significantly different, whereas decreases were observed at days 7 and 14 (p<0.05). CHX (14.73°) and NaOCl (15.82°) demonstrated the lowest contact angles, Triton an intermediate value (19.35°), and EDTA the highest (21.46°). Conclusion: Triton maintained stable pH values during the first week and provided satisfactory dentin wettability, superior to EDTA but lower than CHX and NaOCl. These properties support its potential as a next-generation irrigant that combines multiple functions in a single solution.
- 29 September 2025
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 29 (10) , 481
Effect of combined use of reinforcement materials on the fracture resistance of MOD cavity restorations in endodontically treated teeth
Bucco-lingual/palatinal vertical fractures are among the most common fractures found in mesio-occluso-distal (MOD) cavity restorations of endodontically treated teeth. This study aimed to compare the effects of different new-generation reinforcement materials applied to two cervical and coronal segments of the teeth on the fracture resistance of endodontically treated teeth in their coronal restorations. A total of 84 freshly extracted, intact human mandibular molars were selected and treated endodontically according to standardized protocols. Standard MOD cavities were prepared, and the specimens were then randomly divided into seven groups (n = 12) based on the combinations of reinforcement materials applied to the cervical or coronal segments, and a control group. The control group had intact teeth. The experimental groups included combinations of flowable composite (Flow), posterior composite (PC), EverX flow (Xflow), EverX posterior (XP), PC, and Ribbond (RIB). After thermocycling, fracture resistance was evaluated using a universal testing machine, and failure patterns were examined under a stereomicroscope. Data were analyzed using the Kruskal-Wallis H test, following a Shapiro-Wilk test that indicated the data did not follow a normal distribution (p < .05). A statistically significant difference was observed between the groups (p < .05). Group 5, which had RIB flow and XP restoration structure, exhibited the highest fracture resistance (1827.90 N), while Group 1, which had Flow and PC restoration structure, demonstrated the lowest fracture resistance (1121.98 N). Fiber-reinforced structures demonstrate superior fracture resistance compared to the other groups (p < .05). There was no significant difference between conventional restoration and Ribbond in the coronal segment (p > .05). Using fiber-reinforced restoration in the cervical segment increases fracture resistance more than in the coronal segment. Fiber-reinforced composites are easily packable and demonstrate higher fracture resistance than Ribbond. Resin-reinforced composite combinations used in cervical and coronal applications improve fracture resistance and can be safely applied for MOD cavity restoration of endodontically treated teeth.
- 29 September 2025
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 29 (10) , 481
Effect of combined use of reinforcement materials on the fracture resistance of MOD cavity restorations in endodontically treated teeth
Bucco-lingual/palatinal vertical fractures are among the most common fractures found in mesio-occluso-distal (MOD) cavity restorations of endodontically treated teeth. This study aimed to compare the effects of different new-generation reinforcement materials applied to two cervical and coronal segments of the teeth on the fracture resistance of endodontically treated teeth in their coronal restorations. A total of 84 freshly extracted, intact human mandibular molars were selected and treated endodontically according to standardized protocols. Standard MOD cavities were prepared, and the specimens were then randomly divided into seven groups (n = 12) based on the combinations of reinforcement materials applied to the cervical or coronal segments, and a control group. The control group had intact teeth. The experimental groups included combinations of flowable composite (Flow), posterior composite (PC), EverX flow (Xflow), EverX posterior (XP), PC, and Ribbond (RIB). After thermocycling, fracture resistance was evaluated using a universal testing machine, and failure patterns were examined under a stereomicroscope. Data were analyzed using the Kruskal-Wallis H test, following a Shapiro-Wilk test that indicated the data did not follow a normal distribution (p < .05). A statistically significant difference was observed between the groups (p < .05). Group 5, which had RIB flow and XP restoration structure, exhibited the highest fracture resistance (1827.90 N), while Group 1, which had Flow and PC restoration structure, demonstrated the lowest fracture resistance (1121.98 N). Fiber-reinforced structures demonstrate superior fracture resistance compared to the other groups (p < .05). There was no significant difference between conventional restoration and Ribbond in the coronal segment (p > .05). Using fiber-reinforced restoration in the cervical segment increases fracture resistance more than in the coronal segment. Fiber-reinforced composites are easily packable and demonstrate higher fracture resistance than Ribbond. Resin-reinforced composite combinations used in cervical and coronal applications improve fracture resistance and can be safely applied for MOD cavity restoration of endodontically treated teeth.