Santina Rocchi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Santina Rocchi has a total of 147 co-authors. Here are the top co-authors by number of shared publications:
- Valerio Vignoli
University of Siena
81 shared publications - Ada Fort
University of Siena
80 shared publications - Tommaso Addabbo
University of Siena
38 shared publications Marco Mugnaini
Department of Information Engineering and Mathematics, University of Siena, Via Roma, 56 - 53100, Italy
17 shared publicationsM. Alioto
Information Engineering Dept., University of Siena, Via Roma, 56 Siena, 53100, Italy
16 shared publicationsM. Mugnaini
Dept. of Information Engineering and Mathematics, University of Siena. Via Roma, 56 - Siena, Italy
15 shared publications
Latest Publications
- 1 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 5-16
QCM Biosensors for the Detection of Tumor Released Exosomes
In this paper the development and the characterization of QCM biosensors for the detection of exosomes is presented. Exosomes are cell-derived vesicles that are present in many biological fluids, and that possess diagnostic potential in the oncologic field. From tests with physiological solutions and human plasma, the developed biosensors have proved to give a rapid response (within minutes) with high sensitivity and specificity against the PSMA antigen.
- 1 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 5-16
QCM Biosensors for the Detection of Tumor Released Exosomes
In this paper the development and the characterization of QCM biosensors for the detection of exosomes is presented. Exosomes are cell-derived vesicles that are present in many biological fluids, and that possess diagnostic potential in the oncologic field. From tests with physiological solutions and human plasma, the developed biosensors have proved to give a rapid response (within minutes) with high sensitivity and specificity against the PSMA antigen.
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 1488-1491
A heuristic reliable model for guarded capacitive sensors to measure displacements
In this paper we analyze and compare different analytical models proposed in literature to estimate the sensing capacitance of guarded capacitive sensors for displacement measurement. The analysis is carried out by means of parametric numerical calculations based on Finite Element Analysis. Adopting an heuristic approach, we propose to modify one of the presented models with a polynomial correcting factor to obtain a better accurate estimation of the sensing capacitance, for a wide range of distances. The robustness of the presented model has been validated by means of parametric numerical perturbations.
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 1488-1491
A heuristic reliable model for guarded capacitive sensors to measure displacements
In this paper we analyze and compare different analytical models proposed in literature to estimate the sensing capacitance of guarded capacitive sensors for displacement measurement. The analysis is carried out by means of parametric numerical calculations based on Finite Element Analysis. Adopting an heuristic approach, we propose to modify one of the presented models with a polynomial correcting factor to obtain a better accurate estimation of the sensing capacitance, for a wide range of distances. The robustness of the presented model has been validated by means of parametric numerical perturbations.
- 1 April 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Theoretical modeling of an electrostatic Gas-Path debris detection system with experimental validation
We discuss the general theoretical characterization of a Gas-Path debris detection monitoring system based on electrostatic sensors and charge amplifiers. We provide the analytical expression of the time-varying charge induced by the moving debris on the sensor surface, discussing the effects of the amplifier bandwidth on the shape of the output voltage signal. Theoretical results have been validated with experiments.
- 1 April 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Theoretical modeling of an electrostatic Gas-Path debris detection system with experimental validation
We discuss the general theoretical characterization of a Gas-Path debris detection monitoring system based on electrostatic sensors and charge amplifiers. We provide the analytical expression of the time-varying charge induced by the moving debris on the sensor surface, discussing the effects of the amplifier bandwidth on the shape of the output voltage signal. Theoretical results have been validated with experiments.
- 1 March 2015
- Published by Elsevier in Measurement
- Vol. 64, 138-146
Theoretical characterization of a gas path debris detection monitoring system based on electrostatic sensors and charge amplifiers
- 1 March 2015
- Published by Elsevier in Measurement
- Vol. 64, 138-146
Theoretical characterization of a gas path debris detection monitoring system based on electrostatic sensors and charge amplifiers
- 1 February 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Improved model for the capacitance estimation of guarded capacitive sensors
We present a polynomial correction factor to improve the analytical models proposed in literature to estimate the sensing capacitance of guarded capacitive for displacement measurement. The correction factor has been obtained by fitting parametric numerical calculations based on Finite Element Analysis. The proposed heuristic model provides accurate estimations for a wide range of measuring distances. The robustness of the model has been tested by varying the size of the insulator gap g, even considering the sensor mounted in a recess of the fixed grounded plate with different geometries.
- 1 February 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Improved model for the capacitance estimation of guarded capacitive sensors
We present a polynomial correction factor to improve the analytical models proposed in literature to estimate the sensing capacitance of guarded capacitive for displacement measurement. The correction factor has been obtained by fitting parametric numerical calculations based on Finite Element Analysis. The proposed heuristic model provides accurate estimations for a wide range of measuring distances. The robustness of the model has been tested by varying the size of the insulator gap g, even considering the sensor mounted in a recess of the fixed grounded plate with different geometries.
- 1 February 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Metal oxide nanograined chemosensor: Influence of film microstructure on gas sensing
In this work the case of spherical grains will be discussed in order to point out that the reduction of the sensing film grain size changes the behavior, not always giving a better performance in terms of sensitivity, with respect to large grained films. The model was focused on p-type materials and some simulation results for YCoO3 are shown and discussed.
- 1 February 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Metal oxide nanograined chemosensor: Influence of film microstructure on gas sensing
In this work the case of spherical grains will be discussed in order to point out that the reduction of the sensing film grain size changes the behavior, not always giving a better performance in terms of sensitivity, with respect to large grained films. The model was focused on p-type materials and some simulation results for YCoO3 are shown and discussed.
- 9 January 2015
- Published by Springer Nature
- p. 387-391
Gas Turbine Thermoelements Availability Analysis
- 9 January 2015
- Published by Springer Nature
- p. 387-391
Gas Turbine Thermoelements Availability Analysis
- 1 February 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
HMM used for component parameters apportionment
This paper deals with the problem of the correct allocation of the reliability failure and repair rates of simple systems composed of two elements only, once the service shop history is fully mapped and theoretical hypothesis on system parameters are available. Actually, the problem of data collection and the management of censored ones is one of the most important affecting both reliability, availability and safety analysis. Usually the design is based on a partial collection of biased and censored field data. To improve the predictions and make them more adherent to actual field system life, in this paper, the authors suggest to implement a simple homogeneous Markov model and compare the transition probabilities with the ones coming from a Hidden Markov Structure (HMS or HM Model). The results obtained allows for retrofitting the supposed system failure and repair rates. In this paper the classical Markov Model approach is presented and compared with the HMM one, on one simple and generalized example. In such framework, parameters apportionment, assumes the meaning of system parameters tuning based on the shop history outcomes to match actual system behavior.
- 1 February 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
HMM used for component parameters apportionment
This paper deals with the problem of the correct allocation of the reliability failure and repair rates of simple systems composed of two elements only, once the service shop history is fully mapped and theoretical hypothesis on system parameters are available. Actually, the problem of data collection and the management of censored ones is one of the most important affecting both reliability, availability and safety analysis. Usually the design is based on a partial collection of biased and censored field data. To improve the predictions and make them more adherent to actual field system life, in this paper, the authors suggest to implement a simple homogeneous Markov model and compare the transition probabilities with the ones coming from a Hidden Markov Structure (HMS or HM Model). The results obtained allows for retrofitting the supposed system failure and repair rates. In this paper the classical Markov Model approach is presented and compared with the HMM one, on one simple and generalized example. In such framework, parameters apportionment, assumes the meaning of system parameters tuning based on the shop history outcomes to match actual system behavior.
- 1 February 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A new wireless interface for resistive chemical sensors
This paper presents the design, realization, and performance measurements of a wireless interface prototype for chemoresistive sensors. The new design aims at reducing the hardware components of the sensing node in order to have an efficient sensing mechanism in terms of time and power consumption. In our design the signal transmitted by the sensing node is directly proportional to the sensing film resistance. This means that minimum signal conditioning and no data processing at all are needed. With conventional sensing node, the processing time to produce an output signal from the measurement may have a significant impact. With our approach, this time is only needed on the sink node where higher performance processors can be used. The system is tested with a commercial variable resistance gas sensor (MOX) and proved to be suitable for various combinations of CO and NO 2 gas concentrations.
- 1 February 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A new wireless interface for resistive chemical sensors
This paper presents the design, realization, and performance measurements of a wireless interface prototype for chemoresistive sensors. The new design aims at reducing the hardware components of the sensing node in order to have an efficient sensing mechanism in terms of time and power consumption. In our design the signal transmitted by the sensing node is directly proportional to the sensing film resistance. This means that minimum signal conditioning and no data processing at all are needed. With conventional sensing node, the processing time to produce an output signal from the measurement may have a significant impact. With our approach, this time is only needed on the sink node where higher performance processors can be used. The system is tested with a commercial variable resistance gas sensor (MOX) and proved to be suitable for various combinations of CO and NO 2 gas concentrations.