Three-dimensional computer-assisted navigation for the placement of cannulated hip screws. A pilot study
Authors:
- Marcus Christian MüllerMMMarcus Christian Müller
- Peter BeleiPBPeter Belei
- Peter H PennekampPPPeter H Pennekamp
- Koroush KabirKKKoroush Kabir
- Dieter C WirtzDWDieter C Wirtz
- Christof BurgerCBChristof Burger
- Oliver WeberOWOliver Weber
- 23 February 2012
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 36 (7) , 1463-1469
Abstract
Purpose Medial femoral neck fractures are common, and closed reduction and internal fixation by three cannulated screws is an accepted method for the surgical treatment. Computer navigation for screw placement may reduce fluoroscopy time, the number of guidewire passes and optimise screw placement. Methods In the context of a sawbone study, a computer-assisted planning and navigation system based on 3D-imaging for guidewire placement in the femoral neck was tested to improve screw placement. Three screws were inserted into 12, intact, femoral sawbones using the conventional technique and into 12, intact, femoral sawbones guided by the computer-based navigation system. Guidewire and subsequent screw placement in the femoral neck were evaluated. Results Use of the navigation system resulted in a significant reduction of the number of drilling attempts (p ≤ 0.05) and achieved optimised accuracy of implant placement by attaining significantly better screw parallelism (p ≤ 0.05) and significantly enlarged neck-width coverage by the three screws (p ≤ 0.0001). Computer assistance significantly increased the number of fluoroscopic images (p ≤ 0.001) and the operation time (p ≤ 0.0001). Conclusions Three-dimensional computer-assisted navigation improves accuracy of cannulated screw placement in femoral neck while increasing the number of fluoroscopic images and operation time. Additional studies including fractured sawbones and cadaver models with the goal of reducing operation time are indispensable before introduction of this navigation system into clinical practice.Keywords
This publication has 23 references indexed in Scilit:
- Evaluation of a fluoroscopy-based navigation system enabling a virtual radiation-free preview of X-ray images for placement of cannulated hip screws. A cadaver studyComputer Aided Surgery, 2011
- Three-Dimensional Fluoroscopy For Evaluation of Articular Reduction and Screw Placement in Calcaneal FracturesFoot & Ankle International, 2007
- Image guidance in pelvic and acetabular surgery—Expectations, success and limitationsInjury, 2007
- Safety of Computer-assisted Surgery for Cannulated Hip ScrewsClinical Orthopaedics and Related Research, 2007
- Experimental validation of noninvasive referencing in navigated procedures on long bonesJournal of Orthopaedic Research, 2006
- The complications of displaced intracapsular fractures of the hipThe Journal of Bone and Joint Surgery. British volume, 2005
- Fluoroscopy-Based Surgical Navigation versus Fluoroscopic Guidance to Control Guide Wire Insertion for Osteosynthesis of Femoral Neck FracturesEuropean Journal of Trauma, 2004
- Untersuchungen zur Bildqualität, Hochkontrastauflösung und Dosis am Stamm- und Gliedmaßenskelett mit einem neuen dedizierten CT-System (ISO-C-3D)RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2002
- Radiation Exposure to the Orthopaedic Surgical Team During Fluoroscopy: "How Far Away Is Far Enough?"Journal of Orthopaedic Trauma, 1997
- Quality of Reduction and Cortical Screw Support in Femoral Neck Fractures An Analysis of 72 Fractures with a New Computerized Measuring MethodJournal of Orthopaedic Trauma, 1995