Time-absorbance profile ratio background correction: introducing TAP to correct for spectral overlap in high-resolution continuum source graphite furnace atomic absorption spectrometry
- 27 September 2021
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 36 (11) , 2370-2382
Abstract
High-resolution continuum source graphite furnace atomic absorption spectrometry HR CS GFAAS provides information about the vicinity of the analytical line, thus effectively transforming a 2-dimension technique (time versus absorbance) into a 3-dimension one (by adding wavelength information), which represents a key advantage when dealing with potential spectral overlaps. Indeed, the occurrence of diatomic molecule absorption often results in high background values in classical AAS, affecting many analyses. The high spectral resolution provided by HR CS AAS in this third dimension enables the use of new tools, first to detect and later to solve this problem. Currently, the software of commercially available HR CS AAS spectrometers is equipped with an algorithm for interference correction, the so-called least-squares background correction (LSBC). Using a spectrum from the interfering species as a correction model, LSBC can correct for the spectral interference by subtracting it. Nevertheless, this approach still poses some problems (e.g., the need to identify the overlapping species). Moreover, there is still a lot of information contained in every measurement that is essentially unused and can help in correcting for spectral overlaps. The time-absorbance profile (TAP) of a species, measured under the same instrumental HR CS AAS conditions using a GF as the atomizer, should be the same at every wavelength measured. Therefore, using a TAP normalized spectrum of the interfering species should be sufficient to subtract it from the normalized absorbance of the atomic line, leaving only the analytical signal of the analyte. This paper proposes the use of such an approach for the first time and discusses in detail how the TAP method can be deployed, without the need to perform any additional measurements or know in advance the nature of the overlapping species. The usefulness of TAP correction for circumventing spectral overlaps and reaching a good agreement with certified/reference values is demonstrated in various situations (e.g., direct determination of Pb in NIST 1570a spinach leaves and NIST 1577b bovine liver, of Ni in NIST 1573 tomato leaves, and of Cu in dried plasma spots produced from whole blood Seronorm™), and its current limitations are highlighted as well.Keywords
Funding Information
- European Regional Development Fund (POCTEFA EFA 176/16/DBS)
- Gobierno de Aragón (Grupo E43_20R)
- Ministerio de Ciencia, Innovación y Universidades (PGC2018-093753B-I00)
This publication has 33 references indexed in Scilit:
- Determination of Silicon in Lubricant Oil by High-Resolution Continuum Source Flame Atomic Absorption Spectrometry Using Least-Square Background Correction and Internal StandardizationAnalytical Letters, 2011
- Solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry to monitor the biodistribution of gold nanoparticles in mice tissue after intravenous administrationJournal of Analytical Atomic Spectrometry, 2010
- Correction of structured molecular background by means of high-resolution continuum source electrothermal atomic absorption spectrometry—Determination of antimony in sediment reference materials using direct solid samplingTalanta, 2009
- Internal standardization and least-squares background correction in high-resolution continuum source flame atomic absorption spectrometry to eliminate interferences on determination of Pb in phosphoric acidSpectrochimica Acta Part B: Atomic Spectroscopy, 2008
- Investigation of artifacts caused by deuterium background correction in the determination of phosphorus by electrothermal atomization using high-resolution continuum source atomic absorption spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 2008
- Determination of aluminum in highly concentrated iron samples: Study of interferences using high-resolution continuum source atomic absorption spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 2007
- Determination of lead in biological samples by high-resolution continuum source graphite furnace atomic absorption spectrometry with direct solid samplingJournal of Analytical Atomic Spectrometry, 2006
- High-resolution continuum-source atomic absorption spectrometry: what can we expect?Journal of the Brazilian Chemical Society, 2003
- Investigation of interferences in the determination of thallium in marine sediment reference materials using high-resolution continuum-source atomic absorption spectrometry and electrothermal atomizationSpectrochimica Acta Part B: Atomic Spectroscopy, 2002
- Observation, identification and correction of structured molecular background by means of continuum source AAS—determination of selenium and arsenic in human urineJournal of Analytical Atomic Spectrometry, 2000