MGM. Carmen García-Poyo

M. Carmen García-Poyo

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


M. Carmen García-Poyo has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Determination of metal oxide and metallic nanoparticles in indoor air samples using mixed cellulose esters filters and spICP-MS: dissolve and shoot

    by Carlos Gómez-Pertusa, M. Carmen García-Poyo, Guillermo Grindlay, Ricardo Pedraza, Adela Yañez, Luis Gras

    In recent years, there has been increasing concern about the adverse health effects of the metallic and metal-containing nanoparticles (NPs) present in indoor environments. Unfortunately, there is no well-stablish method to simultaneously characterize their number and composition. Recently, our research group proposed a strategy for the determination of metallic nanoparticles in air by means spICP-MS based on the aerosol collection on micro-quartz filters and the subsequent extraction using microwave heating in basic media. Although the proposed method allows accurate and precise characterization of NPs, it suffers from practical drawbacks: (i) micro-quartz filter fibers are released into the sample and must be removed prior to analysis to avoid clogging the nebulizer and (ii) the particle distribution detection limits (LODsize) achieved are not low enough (28 nm). In this work, we evaluate the NPs trapping capabilities and possible fiber release of filters of different nature commonly used for indoor air quality control (polytetrafluoroethylene (PTFE), nylon, polycarbonate, and mixed cellulose ester (MCE) filters) and NPs of different chemical composition (ZrO2-, TiO2-, Pt-, AuNPs), size (20–150 nm), and capping agent (citrate, polyethylene glycol, branched polyethyleneimine, and lipoic acid). The results show that MCE is an optimal solution because it is completely dissolved during the microwave heating step and NPs are recovered quantitatively irrespective of their composition and size. The LODs are also improved down to 15 nm and 120 particles per liter of air, low enough to be used for indoor air pollution control. Finally, the proposed method was successfully tested in a simulated (NPs enriched) indoor environment. Graphical abstract


  • Open Access

    Standardization of microwave-assisted extraction procedures for characterizing non-labile metallic nanoparticles in environmental solid samples by means of single particle ICP-MS

    by Carlos Gómez-Pertusa, M. Carmen García-Poyo, Guillermo Grindlay, Ricardo Pedraza, M. Adela Yañez, Luis Gras

    Microwave-assisted extraction (MAE) treatments seem to be a promising sample preparation strategy to isolate nanomaterials (NMs) from environmental samples prior to single particle inductively coupled plasma mass (spICP-MS) determination.


  • Cu fractionation, isotopic analysis, and data processing via machine learning: new approaches for the diagnosis and follow up of Wilson's disease via ICP-MS

    by M. Carmen García-Poyo, Sylvain Bérail, Anne Laure Ronzani, Luis Rello, Elena García-González, Flávio V. Nakadi, Maite Aramendía, Javier Resano, Martín Resano, Christophe Pécheyran

    Information about Cu fractionation and Cu isotopic composition can be paramount when investigating Wilson's disease (WD). This information can provide a better understanding of the metabolism of Cu. Most importantly, it may provide an easy way to diagnose and to follow the evolution of WD patients. For such purposes, protocols for Cu determination and Cu isotopic analysis via inductively coupled plasma mass spectrometry were investigated in this work, both in bulk serum and in the exchangeable copper (CuEXC) fractions. The CuEXC protocol provided satisfactory recovery values. Also, no significant mass fractionation during the whole analytical procedure (CuEXC production and/or Cu isolation) was detected. Analyses were carried out in controls (healthy persons), newborns, patients with hepatic disorders, and WD patients. While the results for Cu isotopic analysis are relevant (e.g., δ65Cu values were lower for both WD patients under chelating treatment and patients with hepatic problems in comparison with those values obtained for WD patients under Zn treatments, controls, and newborns) to comprehend Cu metabolism and to follow up the disease, the parameter that can help to better discern between WD patients and the rest of the patients tested (non-WD) was found to be the REC (relative exchangeable Cu). In this study, all the WD patients showed a REC higher than 17%, while the rest showed lower values. However, since establishing a universal threshold is complicated, machine learning was investigated to produce a model that can differentiate between WD and non-WD samples with excellent results (100% accuracy, albeit for a limited sample set). Most importantly, unlike other ML approaches, our model can also provide an uncertainty metric to indicate the reliability of the prediction, overall opening new ways to diagnose WD.


  • Time-absorbance profile ratio background correction: introducing TAP to correct for spectral overlap in high-resolution continuum source graphite furnace atomic absorption spectrometry

    by Flávio V. Nakadi, M. Carmen García-Poyo, Christophe Pécheyran, Martín Resano

    High-resolution continuum source graphite furnace atomic absorption spectrometry HR CS GFAAS provides information about the vicinity of the analytical line, thus effectively transforming a 2-dimension technique (time versus absorbance) into a 3-dimension one (by adding wavelength information), which represents a key advantage when dealing with potential spectral overlaps. Indeed, the occurrence of diatomic molecule absorption often results in high background values in classical AAS, affecting many analyses. The high spectral resolution provided by HR CS AAS in this third dimension enables the use of new tools, first to detect and later to solve this problem. Currently, the software of commercially available HR CS AAS spectrometers is equipped with an algorithm for interference correction, the so-called least-squares background correction (LSBC). Using a spectrum from the interfering species as a correction model, LSBC can correct for the spectral interference by subtracting it. Nevertheless, this approach still poses some problems (e.g., the need to identify the overlapping species). Moreover, there is still a lot of information contained in every measurement that is essentially unused and can help in correcting for spectral overlaps. The time-absorbance profile (TAP) of a species, measured under the same instrumental HR CS AAS conditions using a GF as the atomizer, should be the same at every wavelength measured. Therefore, using a TAP normalized spectrum of the interfering species should be sufficient to subtract it from the normalized absorbance of the atomic line, leaving only the analytical signal of the analyte. This paper proposes the use of such an approach for the first time and discusses in detail how the TAP method can be deployed, without the need to perform any additional measurements or know in advance the nature of the overlapping species. The usefulness of TAP correction for circumventing spectral overlaps and reaching a good agreement with certified/reference values is demonstrated in various situations (e.g., direct determination of Pb in NIST 1570a spinach leaves and NIST 1577b bovine liver, of Ni in NIST 1573 tomato leaves, and of Cu in dried plasma spots produced from whole blood Seronorm™), and its current limitations are highlighted as well.


  • Determination of Cu in bloodviadirect analysis of dried blood spots using high-resolution continuum source graphite furnace atomic absorption spectrometry

    by M. Carmen García-Poyo, Christophe Pécheyran, Luis Rello, Elena García-González, Sharay Alonso Rodríguez, Flávio V. Nakadi, Maite Aramendía, Martín Resano

    The performance of state-of-the-art high-resolution continuum source graphite furnace atomic absorption spectrometry (HR CS GFAAS) instrumentation and four novel devices to produce dried blood spots of perfectly defined volumes is evaluated with the aim of developing a simple, direct method for the determination of Cu in blood samples. In all cases, it is feasible to obtain accurate quantitative information using any of the four devices tested (Mitra, HemaXis DB10, Capitainer qDBS and HemaPEN) via simple external calibration with aqueous standards. One of the main differences in the performance of such devices is related to the blanks obtained, such that HemaXis DB10 and HemaPEN are preferred when abnormally low Cu levels (500 μg L−1 or lower), associated with some diseases, need to be determined. The results prove that accurate values with RSD values below 10% can be achieved for these devices even for such Cu levels, while for Capitainer qDBS and, to a higher extent, for Mitra, blank variations will ultimately increase the uncertainty. It is important to stress that analysis of four real samples using both venipuncture and all the DBS specimens showed a very good agreement. Thus, the approach proposed could be readily applied, such that patients with disorders requiring Cu control can prepare their own samples and submit them via postal mail to labs for HR CS GFAAS direct and fast analysis.


  • Laser ablation of microdroplets for copper isotopic analysis via MC-ICP-MS. Analysis of serum microsamples for the diagnosis and follow-up treatment of Wilson's disease

    by M. Carmen García-Poyo, Sylvain Bérail, Anne Laure Ronzani, Luis Rello, Elena García-González, Bénédicte Lelièvre, Paul Cales, Flavio V. Nakadi, Maite Aramendía, Martín Resano, et al.

    Cu isotopic analysis can provide valuable insight when investigating Wilson's disease (WD), but one of the problems related to this type of study is that usually low sample volumes are available and/or low Cu concentrations are found in these samples. This paper presents a new approach for Cu isotope ratio determination that requires only 1 μL of pre-treated serum sample per replicate (after Cu separation and preconcentration to a Cu concentration range between 0.3 and 4 mg L−1). Cu determination was carried out by direct μ-injection of 1 μL of pretreated serum samples into an ICP-MS, offering a LOD of 3 μg L−1. For Cu isotopic analysis, the method presented is based on micro-volume deposition on a pure silicon wafer and subsequent ablation analysis by fsLA-MC-ICP-MS. Cu isotopic analysis of NIST 3114 at 1 mg L−1 Cu concentration with the self-bracketing method provided average δ65Cu values of −0.01 ± 0.19‰ (2SD) and an internal precision value of 517 ppm. This method was deployed for the analysis of serum samples from WD patients under different treatments, as well as healthy newborns and patients with other liver disorders. The results seem to link decreased δ65Cu values to Cu release from the liver, further demonstrating the potential of this type of analysis in the biomedical context.