Lung ultrasound during hemodialysis: the role in the assessment of volume status
- 25 July 2013
- journal article
- Published by Springer Nature in International Urology and Nephrology
- Vol. 46 (1) , 169-174
Abstract
Fluid balance is important in patients undergoing hemodialysis. “Dry” weight is usually estimated clinically, and also, bioimpedance is considered reliable. Ultrasonography of inferior vena cava (IVC) estimates central venous pressure, and lung ultrasound evaluates extravascular (counting B-lines artifact) lung water. Our study was aimed to clarify their usefulness in the assessment of volume status during hemodialysis. A total of 71 consecutive patients undergoing hemodialysis underwent lung and IVC ultrasound and bioimpedance spectroscopy immediately before and after dialysis. There was a significant reduction in the number of B-lines (3.13 vs 1.41) and in IVC diameters (end-expiratory diameter 1.71 vs 1.37; end-inspiratory diameter 1.19 vs 0.95) during dialysis. The reduction in B-lines correlated with weight reduction during dialysis (p 0.007); none of the parameters concerning the IVC correlated with fluid removal. At the end of the dialysis session, the total number of B-lines correlated with bioimpedance residual weight (p 0.002). The reduction in B-lines correlated with fluid loss due to hemodialysis, despite the small pre-dialysis number, confirming that lung ultrasound can identify even modest variations in extravascular lung water. IVC ultrasound, which reflects the intravascular filling grade, might not be sensitive enough to detect rapid volume decrease. Clinically estimated dry weight had a poor correlation with both bioimpedance and ultrasound techniques. Post-dialysis B-lines number correlates with residual weight assessed with bioimpedance, suggesting a role for ultrasound in managing hemodialysis patients.Keywords
This publication has 30 references indexed in Scilit:
- Assessment of ultrasound acoustic artifacts in patients with acute dyspnea: a multicenter studyActa Radiologica, 2012
- Assessment of Extracellular Fluid Volume and Fluid Status in Hemodialysis Patients: Current Status and Technical AdvancesSeminars in Dialysis, 2012
- Thoracic ultrasonography: A new method for the work-up of patients with dyspneaJournal of Ultrasound, 2011
- Inferior Vena Cava Diameter and Left Atrial Diameter Measure Volume but Not Dry WeightClinical Journal of the American Society of Nephrology, 2011
- Can Lung Comets Be Counted as “Objects”?JACC: Cardiovascular Imaging, 2011
- Fluid Retention Is Associated With Cardiovascular Mortality in Patients Undergoing Long-Term HemodialysisCirculation, 2009
- Wet or Dry in Dialysis—Can New Technologies Help?Seminars in Dialysis, 2009
- Current state of bioimpedance technologies in dialysisNephrology Dialysis Transplantation, 2007
- Usefulness of ultrasound lung comets as a nonradiologic sign of extravascular lung waterThe American Journal of Cardiology, 2004
- Multifrequency bioimpedance in assessment of dry weight in haemodialysisNephrology Dialysis Transplantation, 1996