ISME —incoherent sampling of multi‐echo data to minimize cardiac‐induced noise in brain maps of R2*$ {R}_2^{\ast } $ and magnetic susceptibility
Open Access
- 17 September 2025
- journal article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (2) , 897-911
Abstract
Purpose: Maps of the MRI parameters and magnetic susceptibility () enable the investigation of microscopic tissue changes in brain disease. However, cardiac‐induced signal instabilities increase the variability of brain maps of and . In this study, we introduce incoherent sampling of multi‐echo data (ISME)—a sampling strategy that minimizes the level of cardiac‐induced instabilities in brain maps of and . Methods: ISME uses phase‐encoding gradients to shift the k‐space frequency of the acquired data between consecutive readouts of a multi‐echo train. As a result, the multi‐echo data at a given k‐space index are acquired at different phases of the cardiac cycle. We compare the variability of and maps acquired with ISME and with standard multi‐echo trajectories in N = 10 healthy volunteers. We investigate the effect of both trajectories on the spatial aliasing of pulsating MR signals and propose a weighted least‐squares approach for the estimation of that accounts for the increase of the residuals with echo time. Results: ISME reduces the variability of and maps across repetitions by 25%/26%/21% and 24%/32%/23% in the cerebellum/brainstem/whole brain, respectively. With ISME, the spatial aliasing of pulsating MR signals is incoherent between raw echo images, leading to visually sharper maps. The proposed weighted least‐squares approach for the estimation of reduces the dependence of the fitting residuals on echo time and the variability of by an additional 3%/2%/1% in the cerebellum/brainstem/whole brain. Conclusion: ISME allows the mitigation of cardiac‐induced signal instabilities in brain maps of and , improving reproducibility.Keywords
Funding Information
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (320030_184784, CR00I5_235940, 32003B_182615, CRSII5_202276)
- Royal Society
This publication has 90 references indexed in Scilit:
- Measuring brain beats: Cardiac‐aligned fast functional magnetic resonance imaging signalsHuman Brain Mapping, 2022
- Restoring statistical validity in group analyses of motion‐corrupted MRI dataHuman Brain Mapping, 2022
- Improvement of reproducibility in quantitative susceptibility mapping (QSM) and transverse relaxation rates () after physiological noise correctionJournal of Magnetic Resonance Imaging, 2018
- Motion artifacts in MRI: A complex problem with many partial solutionsJournal of Magnetic Resonance Imaging, 2015
- Application of a Fourier-based method for rapid calculation of field inhomogeneity due to spatial variation of magnetic susceptibilityConcepts in Magnetic Resonance Part B, 2005
- Motion correction using the k‐space phase difference of orthogonal acquisitionsMagnetic Resonance in Medicine, 2002
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- Postacquisition suppression of large‐vessel BOLD signals in high‐resolution fMRIMagnetic Resonance in Medicine, 2001
- Physiological noise in oxygenation‐sensitive magnetic resonance imagingMagnetic Resonance in Medicine, 2001
- The NMR phased arrayMagnetic Resonance in Medicine, 1990