Modeling Stented Coronary Arteries: Where We are, Where to Go
- 23 October 2012
- journal article
- research article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 41 (7) , 1428-1444
Abstract
In the last two decades, numerical models have become well-recognized and widely adopted tools to investigate stenting procedures. Due to limited computational resources and modeling capabilities, early numerical studies only involved simplified cases and idealized stented arteries. Nowadays, increased computational power allows for numerical models to meet clinical needs and include more complex cases such as the implantation of multiple stents in bifurcations or curved vessels. Interesting progresses have been made in the numerical modeling of stenting procedures both from a structural and a fluid dynamics points of view. Moreover, in the drug eluting stents era, new insights on drug elution capabilities are becoming essential in the stent development. Lastly, image-based methods able to reconstruct realistic geometries from medical images have been proposed in the recent literature aiming to better describe the peculiar anatomical features of coronary vessels and increase the accuracy of the numerical models. In this light, this review provides a comprehensive analysis of the current state-of-the-art in this research area, discussing the main methodological advances and remarkable results drawn from a number of significant studies.Keywords
This publication has 108 references indexed in Scilit:
- The Multi-Scale Modelling of Coronary Blood FlowAnnals of Biomedical Engineering, 2012
- INtimal hyPerplasia evAluated by oCT in de novo COROnary lesions treated by drug-eluting balloon and bare-metal stent (IN-PACT CORO): study protocol for a randomized controlled trialTrials, 2012
- Increased artery wall stress post-stenting leads to greater intimal thickeningLaboratory Investigation, 2011
- Multi-scale simulations of the dynamics of in-stent restenosis: impact of stent deployment and designInterface Focus, 2011
- Fusion of 3D QCA and IVUS/OCTThe International Journal of Cardiovascular Imaging, 2011
- Factors that affect mass transport from drug eluting stents into the artery wallBioMedical Engineering OnLine, 2010
- Deformation-induced hydrolysis of a degradable polymeric cylindrical annulusBiomechanics and Modeling in Mechanobiology, 2009
- Thrombus causes fluctuations in arterial drug delivery from intravascular stentsJournal of Controlled Release, 2008
- Simulation of stent deployment in a realistic human coronary arteryBioMedical Engineering OnLine, 2008
- Intravascular drug release kinetics dictate arterial drug deposition, retention, and distributionJournal of Controlled Release, 2007