A randomised prospective evaluation of ceramic-on-ceramic and ceramic-on-highly cross-linked polyethylene bearings in the same patients with primary cementless total hip arthroplasty
- 3 August 2013
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 37 (11) , 2131-2137
Abstract
Very few studies have compared alumina-on-alumina ceramic and alumina-on-highly cross-linked polyethylene bearings in the same patient. The purpose of this prospective randomised study was to compare the clinical and radiographic results and the prevalence of osteolysis in cementless total hip arthroplasty using an alumina-on-alumina and alumina-on-highly cross-linked polyethylene bearings in young active patients. We prospectively compared the results of 100 patients (200 hips) who had undergone a cementless total hip arthroplasty with an alumina-on-alumina ceramic bearing in one hip and an alumina-on-highly cross-linked polyethylene in the other. There were 66 men and 34 women with a mean age of 45.3 years (range, 21–49 years) at the time of surgery. The mean follow-up was 12.4 years (range, 11–13 years). The patients were assessed clinically and radiographically at three months, one year, and annually thereafter. Harris hip, Western Ontario and McMaster Universities Osteoarthritis Index, and University of California, Los Angeles activity scores did not show statistically significant differences between the two groups of bearings preoperatively or at the time of final follow-up. Radiographic findings of the component were not significantly different between the two groups. The mean polyethylene linear penetration was 0.031 ± 0.004 mm per year. No hips in either group displayed osteolysis. The Kaplan-Meier survivorship with revision as the end point at 12.4 years was 100 % (95 % confidence interval [CI], 94–100 %) for the femoral component in both groups and 99 % (95 %CI, 93–100 %) for the acetabular component. The clinical and radiographic results of using an alumina-on-alumina ceramic and alumina-on-highly cross-linked polyethylene bearings were similar.Keywords
This publication has 44 references indexed in Scilit:
- Thirty years of experience with alumina-on-alumina bearings in total hip arthroplastyInternational Orthopaedics, 2010
- Excellent results with cementless total hip arthroplasty and alumina-on-alumina pairing: minimum ten-year follow-upInternational Orthopaedics, 2010
- Alumina-on-alumina ceramic versus metal-on-highly cross-linked polyethylene bearings in total hip arthroplasty: a comparative studyInternational Orthopaedics, 2009
- Alumina-on-alumina Total Hip Arthroplasty in Young Patients: Diagnosis is More Important than AgeClinical Orthopaedics and Related Research, 2009
- Wear Analysis in THA Utilizing Oxidized Zirconium and Crosslinked PolyethyleneClinical Orthopaedics and Related Research, 2009
- Squeaking HipsJournal of Bone and Joint Surgery, 2008
- High Incidence of Squeaking in THAs with Alumina Ceramic-on-ceramic BearingsClinical Orthopaedics and Related Research, 2008
- Wear, Debris, and Biologic Activity of Cross-linked Polyethylene in the KneeClinical Orthopaedics and Related Research, 2004
- A comparison of polyethylene wear in hips with cobalt-chrome or zirconia headsThe Journal of Bone and Joint Surgery. British volume, 2001
- Nonparametric Estimation from Incomplete ObservationsJournal of the American Statistical Association, 1958