Comprehensive Diagnostic Assessment of Inverter Failures in a Utility-Scale Solar Power Plant: A Case Study Based on Field and Laboratory Validation
Open Access
Abstract
Recurrent catastrophic inverter failures significantly undermine the reliability and economic viability of utility-scale photovoltaic (PV) power plants. This paper presents a comprehensive investigation of severe inverter destruction incidents at the Kopli Solar Power Plant, Estonia, by integrating controlled laboratory simulations with extensive field monitoring. Initially, detailed laboratory experiments were conducted to replicate critical DC-side short-circuit scenarios, particularly focusing on negative DC input terminal faults. The results consistently showed these faults rapidly escalating into multi-phase short-circuits and sustained ground-fault arcs due to inadequate internal protection mechanisms, semiconductor breakdown, and delayed relay response. Subsequently, extensive field-based waveform analyses of multiple inverter failure events captured identical fault signatures, thereby conclusively validating laboratory-identified failure mechanisms. Critical vulnerabilities were explicitly identified, including insufficient isolation relay responsiveness, inadequate semiconductor transient ratings, and ineffective internal insulation leading to prolonged arc conditions. Based on the validated findings, the paper proposes targeted inverter design enhancements—particularly advanced DC-side protective schemes, rapid fault-isolation mechanisms, and improved internal insulation practices. Additionally, robust operational and monitoring guidelines are recommended for industry-wide adoption to proactively mitigate future inverter failures. The presented integrated methodological framework and actionable recommendations significantly contribute toward enhancing inverter reliability standards and operational stability within grid-connected photovoltaic installations.Keywords
This publication has 20 references indexed in Scilit:
- Effective Protection Distance of SPD in PV System Under Lightning SurgeIEEE Journal of Photovoltaics, 2024
- Analysis and Suppression of Active Power Backflow of Three-Phase Common DC-Bus Cascaded H-Bridge PV Grid-Connected Inverter During LVRTIEEE Journal of Emerging and Selected Topics in Power Electronics, 2021
- A Machine Learning Evaluation of Maintenance Records for Common Failure Modes in PV InvertersIEEE Access, 2020
- Review of O&M Practices in PV Plants: Failures, Solutions, Remote Control, and Monitoring ToolsIEEE Journal of Photovoltaics, 2020
- Harmonic Analysis of Multi-Parallel Grid- Connected Inverters in Distribution Networks: Emission and Immunity Issues in the Frequency Range of 0-150 kHzIEEE Access, 2020
- Reliability Modeling of PV Systems Based on Time-Varying Failure RatesIEEE Access, 2020
- The Effect of Inverter Failures on the Return on Investment of Solar Photovoltaic SystemsIEEE Access, 2017
- Technique for Fast Detection of Short Circuit Current in PV Distributed GeneratorIEEE Power and Energy Technology Systems Journal, 2016
- DC Arc Flash Studies for Solar Photovoltaic Systems: Challenges and RecommendationsIEEE Transactions on Industry Applications, 2015
- Impact of Photovoltaic-Oriented DC Stray Current Corrosion on Large-Scale Solar Farms' Grounding and Third-Party Infrastructure: Modeling and AssessmentIEEE Transactions on Industry Applications, 2015