Design of patient specific bone stiffness mimicking scaffold
- 6 July 2021
- journal article
- research article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 235 (12) , 1453-1462
Abstract
The difference in stiffness of a patient’s bone and bone implant causes stress shielding. Thus, implants which match the stiffness of bone of the patient result in better bone growth and osseointegration. Variation in porosity is one of the methods to obtain implants with different stiffness values. This study proposes a novel method to design biomimetic bone graft implant based on computed tomography (CT) scan data, that creates similar pre- and post-implant mechanical environment on peri-implant bone. The design methodology is demonstrated by taking three different sections of human femur bone, greater trochanter, diaphysis and epicondyle, with two different implant materials, Ti-6Al-4V and Ti-Mg. Bones from these three sections were replaced with porous implants of effective stiffness of replaced bone, as would have been required after a resection surgery. Models were simulated with physiological loading condition using finite element (FE) method. Variation of maximum von Mises stress and average strain on peri-prosthetic bone were found to be in the range of −6% to 10.7% and −7% to −17.9% for porous implants and 26% to 50% and −36% to −59% for solid implant respectively compared to natural bone. The results revealed that the porous implants, which have been designed based on CT scan data, can effectively produce mechanical response at peri-implant bone, which is very close to pre-implanted condition. Following this methodology, more osseointegration friendly mechanical environment can be achieved at peri-implant bone for any anatomical location independent of implant materials.Keywords
This publication has 38 references indexed in Scilit:
- Ti–6Al–4V triply periodic minimal surface structures for bone implants fabricated via selective laser meltingJournal of the Mechanical Behavior of Biomedical Materials, 2015
- Powder metallurgical low-modulus Ti–Mg alloys for biomedical applicationsMaterials Science and Engineering: C, 2015
- Failure mechanisms of additively manufactured porous biomaterials: Effects of porosity and type of unit cellJournal of the Mechanical Behavior of Biomedical Materials, 2015
- Effects of scaffold architecture on cranial bone healingInternational Journal of Oral and Maxillofacial Surgery, 2014
- Numerical simulation of load-induced bone structural remodelling using stress-limit criterionComputer Methods in Biomechanics and Biomedical Engineering, 2013
- Hierarchical honeycombs with tailorable propertiesInternational Journal of Solids and Structures, 2012
- Scaffolds for bone healing: Concepts, materials and evidenceInjury, 2011
- The effect of the density–modulus relationship selected to apply material properties in a finite element model of long boneJournal of Biomechanics, 2008
- Selective Electron Beam Melting of Cellular Titanium: Mechanical PropertiesAdvanced Engineering Materials, 2008
- Measurement of local strains induced into the femur by trochanteric Gamma nail implants with one or two distal screwsMedical Engineering & Physics, 2006