Olli Gröhn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Olli Gröhn has a total of 443 co-authors. Here are the top co-authors by number of shared publications:
- Alejandra Sierra
A.I. Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland
12 shared publications - Jaakko Paasonen
A. I. Virtanen Institute for Molecular Sciences, University of Eastern Finland , Neulaniementie 2, FI-70211, Kuopio
11 shared publications Jaakko Paasonen
A. I. Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland
9 shared publicationsShalom Michaeli
Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, USA
9 shared publicationsRaimo A. Salo
A.I. Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland
8 shared publicationsAsla Pitkänen
Department of Neurobiology, A.I. Virtanen Institute for Molecular Medicine, University of Eastern Finland, 70211, Kuopio, Finland
7 shared publications
Latest Publications
- Open Access
- 6 January 2026
- Published by Oxford University Press (OUP) in Cerebral Cortex
- Vol. 36 (1)
Secondary thalamic neuroinflammation associates with disturbed corticothalamic connectivity in a model of severe traumatic brain injury in male rats—a longitudinal study
Traumatic brain injury (TBI) is one of the leading causes of death and disability worldwide. The initial injury initiates a cascade of secondary injury mechanisms, including neuroinflammation and disruption of brain connectivity. In this study, we used the lateral fluid percussion injury model of TBI to investigate the relationship between secondary thalamic inflammation and corticothalamic connectivity disruptions. For this, we followed rats for six months post-injury, during which functional magnetic resonance imaging (fMRI) was conducted under light sedation, as well as diffusion tensor imaging (DTI) and positron emission tomography (PET). PET imaging with [18F]-FEPPA revealed neuroinflammation in the subacute stage in several ipsilateral thalamic nuclei, including the ventral posterior nucleus and lateral nucleus. In the fMRI analysis, we observed initial corticothalamic hypoconnectivity, which partially resolved by six months post-injury. DTI showed persistent increased mean, axial, and radial diffusivity in the ipsilateral thalamic nuclei from two months post-injury. Histological examination confirmed chronic thalamic neuroinflammation and neuronal loss eight months post-TBI. Correlation analyses showed that subacute thalamic neuroinflammation was associated with long-term structural and functional changes. These findings suggest that secondary thalamic inflammation contributes to enduring corticothalamic connectivity disruptions, which may underlie cognitive and sensorimotor deficits observed after TBI.
- 6 January 2026
- Published by Oxford University Press (OUP) in Cerebral Cortex
- Vol. 36 (1)
Open AccessSecondary thalamic neuroinflammation associates with disturbed corticothalamic connectivity in a model of severe traumatic brain injury in male rats—a longitudinal study
Traumatic brain injury (TBI) is one of the leading causes of death and disability worldwide. The initial injury initiates a cascade of secondary injury mechanisms, including neuroinflammation and disruption of brain connectivity. In this study, we used the lateral fluid percussion injury model of TBI to investigate the relationship between secondary thalamic inflammation and corticothalamic connectivity disruptions. For this, we followed rats for six months post-injury, during which functional magnetic resonance imaging (fMRI) was conducted under light sedation, as well as diffusion tensor imaging (DTI) and positron emission tomography (PET). PET imaging with [18F]-FEPPA revealed neuroinflammation in the subacute stage in several ipsilateral thalamic nuclei, including the ventral posterior nucleus and lateral nucleus. In the fMRI analysis, we observed initial corticothalamic hypoconnectivity, which partially resolved by six months post-injury. DTI showed persistent increased mean, axial, and radial diffusivity in the ipsilateral thalamic nuclei from two months post-injury. Histological examination confirmed chronic thalamic neuroinflammation and neuronal loss eight months post-TBI. Correlation analyses showed that subacute thalamic neuroinflammation was associated with long-term structural and functional changes. These findings suggest that secondary thalamic inflammation contributes to enduring corticothalamic connectivity disruptions, which may underlie cognitive and sensorimotor deficits observed after TBI.
- Open Access
- 2 May 2025
- Published by MIT Press in Imaging Neuroscience
- Vol. 3
Multi-coil TMS for preclinical applications in ultra-high-field MRI
Monitoring cortical responses to neuromodulation on preclinical models can elucidate fundamental mechanisms of brain function. Concurrent brain stimulation and imaging is challenging, usually compromising spatiotemporal resolution, accuracy, and versatility. Here, we report on a non-invasive brain stimulation system with electronic control of neuromodulation parameters in a 9.4-T magnetic resonance imaging (MRI) environment. In the imaging scanner, multi-coil transcranial magnetic stimulation (mTMS) is delivered with a 2-coil array, and the MRI signal is measured with a radiofrequency coil. The mTMS can change the stimulus orientation with 1° resolution in a millisecond. Without physically rotating the coils, we evoked orientation-specific muscle responses after cortical stimulation on an anesthetized rat. The mTMS system was successfully implemented and tested with the small-animal MRI, showing minimal interference with B0 and B1+ fields and uncompromised image quality. A delay of 40 ms between the stimulation pulse and fMRI acquisition—similar or even shorter than those previously described in humans—led to artifact-free images. Concurrent electronically targeted brain stimulation and neuroimaging provides a valuable tool for exploring whole-brain network functions, endorsing more efficient treatment protocols.
- 2 May 2025
- Published by MIT Press in Imaging Neuroscience
- Vol. 3
Open AccessMulti-coil TMS for preclinical applications in ultra-high-field MRI
Monitoring cortical responses to neuromodulation on preclinical models can elucidate fundamental mechanisms of brain function. Concurrent brain stimulation and imaging is challenging, usually compromising spatiotemporal resolution, accuracy, and versatility. Here, we report on a non-invasive brain stimulation system with electronic control of neuromodulation parameters in a 9.4-T magnetic resonance imaging (MRI) environment. In the imaging scanner, multi-coil transcranial magnetic stimulation (mTMS) is delivered with a 2-coil array, and the MRI signal is measured with a radiofrequency coil. The mTMS can change the stimulus orientation with 1° resolution in a millisecond. Without physically rotating the coils, we evoked orientation-specific muscle responses after cortical stimulation on an anesthetized rat. The mTMS system was successfully implemented and tested with the small-animal MRI, showing minimal interference with B0 and B1+ fields and uncompromised image quality. A delay of 40 ms between the stimulation pulse and fMRI acquisition—similar or even shorter than those previously described in humans—led to artifact-free images. Concurrent electronically targeted brain stimulation and neuroimaging provides a valuable tool for exploring whole-brain network functions, endorsing more efficient treatment protocols.
- Open Access
Multimodal approach to characterize surgically removed epileptogenic zone from patients with focal drug-resistant epilepsy: from operating room to wet lab
Objective: We have established a comprehensive sample handling protocol designed for the multiscale assessment of epileptogenic tissue. This protocol aims to identify novel therapeutic targets and enhance the diagnosis and stratification of patients with drug-resistant epilepsy, thereby optimizing their treatment with anti-seizure medications and surgical interventions. Methods: Patients with drug-resistant focal epilepsy, recommended for surgical treatment, are recruited after detailed multidisciplinary preoperative evaluation at the Epilepsy Center at Kuopio University Hospital in Finland. A day before the resective surgery, patients undergo magnetic resonance imaging (MRI) including advanced methodologies. During the surgery, each piece of resected tissue is placed under oxygenation on ice-cold artificial cerebral spinal fluid-solution. The pieces are then immediately transported to the laboratory, assessed by a neuropathologist, and sliced for both clinical diagnosis and research. Two adjacent slices are provided for research and are sent to the University of Eastern Finland. Results: The developed sample handling protocol provides the opportunity for detailed characterization of the tissue from the same patient using emerging imaging, electrophysiology, and molecular biology technologies. We have optimized the conditions for preserving the resected tissue alive for electrophysiological measurements and simultaneously making possible ex vivo studies including multi-omics acquisition, electron microscopy, histology, and MRI. Our protocol enables the mapping of functional readouts to structural and molecular alterations in human tissue. Our goal is to integrate multimodal data and co-register the resected tissues within the whole brain’s in vivo MRI space. This approach aims to enhance the characterization and localization of epileptogenic zones and refine surgical treatment targets by identifying abnormalities in global connectivity and structural patterns. Significance: We have successfully developed a systematic protocol for the collection and analysis of multimodal data. This protocol aims to elucidate the structural, functional, and molecular characteristics that render tissue epileptogenic, thereby enhancing the diagnosis and subsequent care of patients with epilepsy. Key points: Introducing a systematic sample handling protocol to assess tissue epileptogenicity at structural, functional and molecular levels. A multimodal approach integrating advanced technology with detailed characterization of epileptogenic tissue properties to obtain patient-specific data. Correlation of data from preoperative MRI and resected tissue to predict tissue pathology from clinical MRI.
Open AccessMultimodal approach to characterize surgically removed epileptogenic zone from patients with focal drug-resistant epilepsy: from operating room to wet lab
Objective: We have established a comprehensive sample handling protocol designed for the multiscale assessment of epileptogenic tissue. This protocol aims to identify novel therapeutic targets and enhance the diagnosis and stratification of patients with drug-resistant epilepsy, thereby optimizing their treatment with anti-seizure medications and surgical interventions. Methods: Patients with drug-resistant focal epilepsy, recommended for surgical treatment, are recruited after detailed multidisciplinary preoperative evaluation at the Epilepsy Center at Kuopio University Hospital in Finland. A day before the resective surgery, patients undergo magnetic resonance imaging (MRI) including advanced methodologies. During the surgery, each piece of resected tissue is placed under oxygenation on ice-cold artificial cerebral spinal fluid-solution. The pieces are then immediately transported to the laboratory, assessed by a neuropathologist, and sliced for both clinical diagnosis and research. Two adjacent slices are provided for research and are sent to the University of Eastern Finland. Results: The developed sample handling protocol provides the opportunity for detailed characterization of the tissue from the same patient using emerging imaging, electrophysiology, and molecular biology technologies. We have optimized the conditions for preserving the resected tissue alive for electrophysiological measurements and simultaneously making possible ex vivo studies including multi-omics acquisition, electron microscopy, histology, and MRI. Our protocol enables the mapping of functional readouts to structural and molecular alterations in human tissue. Our goal is to integrate multimodal data and co-register the resected tissues within the whole brain’s in vivo MRI space. This approach aims to enhance the characterization and localization of epileptogenic zones and refine surgical treatment targets by identifying abnormalities in global connectivity and structural patterns. Significance: We have successfully developed a systematic protocol for the collection and analysis of multimodal data. This protocol aims to elucidate the structural, functional, and molecular characteristics that render tissue epileptogenic, thereby enhancing the diagnosis and subsequent care of patients with epilepsy. Key points: Introducing a systematic sample handling protocol to assess tissue epileptogenicity at structural, functional and molecular levels. A multimodal approach integrating advanced technology with detailed characterization of epileptogenic tissue properties to obtain patient-specific data. Correlation of data from preoperative MRI and resected tissue to predict tissue pathology from clinical MRI.
- Open Access
- 23 January 2025
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 45 (5) , 855-870
Correlation of zero echo time functional MRI with neuronal activity in rats
Zero echo time (zero-TE) pulse sequences provide a quiet and artifact-free alternative to conventional functional magnetic resonance imaging (fMRI) pulse sequences. The fast readouts (<1 ms) utilized in zero-TE fMRI produce an image contrast with negligible contributions from blood oxygenation level-dependent (BOLD) mechanisms, yet the zero-TE contrast is highly sensitive to brain function. However, the precise relationship between the zero-TE contrast and neuronal activity has not been determined. Therefore, we aimed to derive a function to model the temporal dynamics of the zero-TE fMRI signal in response to neuronal activity. Furthermore, we examined the correlation of zero-TE fMRI with neuronal activity across stimulation frequencies. To these ends, we performed simultaneous electrophysiological recordings and zero-TE fMRI in rats subjected to whisker stimulation. The presented impulse response function provides a basis for the statistical modeling of neuronal activity-induced changes in the zero-TE fMRI signal. The temporal characteristics of the zero-TE fMRI response were found to be consistent with the previously postulated non-BOLD hemodynamic origin of the functional contrast. The zero-TE fMRI signal was well predicted by electrophysiological recordings, although systematic stimulation-dependent residuals were also observed, suggesting nonlinearities in neurovascular coupling. We conclude that zero-TE fMRI provides a robust proxy for neuronal activity.
- 23 January 2025
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 45 (5) , 855-870
Open AccessCorrelation of zero echo time functional MRI with neuronal activity in rats
Zero echo time (zero-TE) pulse sequences provide a quiet and artifact-free alternative to conventional functional magnetic resonance imaging (fMRI) pulse sequences. The fast readouts (<1 ms) utilized in zero-TE fMRI produce an image contrast with negligible contributions from blood oxygenation level-dependent (BOLD) mechanisms, yet the zero-TE contrast is highly sensitive to brain function. However, the precise relationship between the zero-TE contrast and neuronal activity has not been determined. Therefore, we aimed to derive a function to model the temporal dynamics of the zero-TE fMRI signal in response to neuronal activity. Furthermore, we examined the correlation of zero-TE fMRI with neuronal activity across stimulation frequencies. To these ends, we performed simultaneous electrophysiological recordings and zero-TE fMRI in rats subjected to whisker stimulation. The presented impulse response function provides a basis for the statistical modeling of neuronal activity-induced changes in the zero-TE fMRI signal. The temporal characteristics of the zero-TE fMRI response were found to be consistent with the previously postulated non-BOLD hemodynamic origin of the functional contrast. The zero-TE fMRI signal was well predicted by electrophysiological recordings, although systematic stimulation-dependent residuals were also observed, suggesting nonlinearities in neurovascular coupling. We conclude that zero-TE fMRI provides a robust proxy for neuronal activity.
- Open Access
- 5 December 2024
- Published by MIT Press in Imaging Neuroscience
- Vol. 2, 1-16
Whole-brain responses to visual and auditory stimuli in anesthetized and minimally restrained awake mice using quiet zero echo time fMRI
Functional MRI (fMRI) is a flexible tool for sensory perception studies in animal models. However, animal fMRI studies are generally performed under anesthesia. Unfortunately, anesthesia affects brain function and sensory processing, complicating the interpretation of the findings. Since there is a growing need for fMRI protocols applicable for awake animals, we optimized a zero echo time Multi-Band Sweep Imaging with a Fourier Transformation (MB-SWIFT) fMRI approach for imaging awake mice. We implemented a 14-day habituation protocol that resulted in merely moderate motion of the mice while being head-fixed with the animals’ body and limbs being free to move. The sensory responsiveness between different states of consciousness was compared by imaging mice with visual and auditory stimulation schemes in the awake state and under ketamine–xylazine anesthesia. In awake mice, we observed a robust whole-brain activation of the ascending auditory and visual pathways, as well as higher sensory processing areas. Under ketamine–xylazine anesthesia, auditory responses were suppressed, and the temporal shapes of fMRI responses were different from those obtained in awake mice. Our results suggest that the quiet and motion-tolerant zero echo time MB-SWIFT approach allows complex behavioral fMRI designs in the awake state that promise to improve our understanding of the underlying mechanisms of perception.
- 5 December 2024
- Published by MIT Press in Imaging Neuroscience
- Vol. 2, 1-16
Open AccessWhole-brain responses to visual and auditory stimuli in anesthetized and minimally restrained awake mice using quiet zero echo time fMRI
Functional MRI (fMRI) is a flexible tool for sensory perception studies in animal models. However, animal fMRI studies are generally performed under anesthesia. Unfortunately, anesthesia affects brain function and sensory processing, complicating the interpretation of the findings. Since there is a growing need for fMRI protocols applicable for awake animals, we optimized a zero echo time Multi-Band Sweep Imaging with a Fourier Transformation (MB-SWIFT) fMRI approach for imaging awake mice. We implemented a 14-day habituation protocol that resulted in merely moderate motion of the mice while being head-fixed with the animals’ body and limbs being free to move. The sensory responsiveness between different states of consciousness was compared by imaging mice with visual and auditory stimulation schemes in the awake state and under ketamine–xylazine anesthesia. In awake mice, we observed a robust whole-brain activation of the ascending auditory and visual pathways, as well as higher sensory processing areas. Under ketamine–xylazine anesthesia, auditory responses were suppressed, and the temporal shapes of fMRI responses were different from those obtained in awake mice. Our results suggest that the quiet and motion-tolerant zero echo time MB-SWIFT approach allows complex behavioral fMRI designs in the awake state that promise to improve our understanding of the underlying mechanisms of perception.
- Open Access
- 14 August 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (17) , 175001
Modeling the stress and forces on multi-channel TMS coil arrays in high-field MRI scanners
Transcranial magnetic stimulation (TMS) is a non-invasive method for stimulating the cortex. Concurrent functional magnetic resonance imaging can show changes in TMS-induced activity in the whole brain, with the potential to inform brain function research and to guide the development of TMS therapy. However, the interaction of the strong current pulses in the TMS coil in the static main magnetic field of the MRI produces high Lorentz forces, which may damage the coil enclosure and compromise the patient’s safety. We studied the time-dependent mechanical behavior and durability of two multi-locus TMS (mTMS) coil arrays inside a high-field MRI bore with finite element modeling. In addition, coil arrays were built and tested based on the simulation results. We found that the current pulses produce shock waves and time-dependent stress distribution in the coil plates. The intensity and location of the maximum stress depend on the current waveform, the coil combination, and the transducer orientation relative to the MRI magnetic field. We found that 30% glass-fiber-filled polyamide is the most durable material out of the six options studied. In addition, novel insights for more durable TMS coil designs were obtained. Our study contributes to a comprehensive understanding of the underlying mechanisms responsible for the structural failure of mTMS coil arrays during stimulation within high static magnetic fields. This knowledge is essential for developing mechanically stable and safe mTMS-MRI transducers.
- 14 August 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (17) , 175001
Open AccessModeling the stress and forces on multi-channel TMS coil arrays in high-field MRI scanners
Transcranial magnetic stimulation (TMS) is a non-invasive method for stimulating the cortex. Concurrent functional magnetic resonance imaging can show changes in TMS-induced activity in the whole brain, with the potential to inform brain function research and to guide the development of TMS therapy. However, the interaction of the strong current pulses in the TMS coil in the static main magnetic field of the MRI produces high Lorentz forces, which may damage the coil enclosure and compromise the patient’s safety. We studied the time-dependent mechanical behavior and durability of two multi-locus TMS (mTMS) coil arrays inside a high-field MRI bore with finite element modeling. In addition, coil arrays were built and tested based on the simulation results. We found that the current pulses produce shock waves and time-dependent stress distribution in the coil plates. The intensity and location of the maximum stress depend on the current waveform, the coil combination, and the transducer orientation relative to the MRI magnetic field. We found that 30% glass-fiber-filled polyamide is the most durable material out of the six options studied. In addition, novel insights for more durable TMS coil designs were obtained. Our study contributes to a comprehensive understanding of the underlying mechanisms responsible for the structural failure of mTMS coil arrays during stimulation within high static magnetic fields. This knowledge is essential for developing mechanically stable and safe mTMS-MRI transducers.
- Open Access
- 18 March 2024
- Published by Wiley in NMR in Biomedicine
- Vol. 37 (8) , e5142
ComBating inter‐site differences in field strength: harmonizing preclinical traumatic brain injury MRI data
Integrating datasets from multiple sites and scanners can increase statistical power for neuroimaging studies but can also introduce significant inter‐site confounds. We evaluated the effectiveness of ComBat, an empirical Bayes approach, to combine longitudinal preclinical MRI data acquired at 4.7 or 9.4 T at two different sites in Australia. Male Sprague Dawley rats underwent MRI on Days 2, 9, 28, and 150 following moderate/severe traumatic brain injury (TBI) or sham injury as part of Project 1 of the NIH/NINDS‐funded Centre Without Walls EpiBioS4Rx project. Diffusion‐weighted and multiple‐gradient‐echo images were acquired, and outcomes included QSM, FA, and ADC. Acute injury measures including apnea and self‐righting reflex were consistent between sites. Mixed‐effect analysis of ipsilateral and contralateral corpus callosum (CC) summary values revealed a significant effect of site on FA and ADC values, which was removed following ComBat harmonization. Bland–Altman plots for each metric showed reduced variability across sites following ComBat harmonization, including for QSM, despite appearing to be largely unaffected by inter‐site differences and no effect of site observed. Following harmonization, the combined inter‐site data revealed significant differences in the imaging metrics consistent with previously reported outcomes. TBI resulted in significantly reduced FA and increased susceptibility in the ipsilateral CC, and significantly reduced FA in the contralateral CC compared with sham‐injured rats. Additionally, TBI rats also exhibited a reversal in ipsilateral CC ADC values over time with significantly reduced ADC at Day 9, followed by increased ADC 150 days after injury. Our findings demonstrate the need for harmonizing multi‐site preclinical MRI data and show that this can be successfully achieved using ComBat while preserving phenotypical changes due to TBI.
- 18 March 2024
- Published by Wiley in NMR in Biomedicine
- Vol. 37 (8) , e5142
Open AccessComBating inter‐site differences in field strength: harmonizing preclinical traumatic brain injury MRI data
Integrating datasets from multiple sites and scanners can increase statistical power for neuroimaging studies but can also introduce significant inter‐site confounds. We evaluated the effectiveness of ComBat, an empirical Bayes approach, to combine longitudinal preclinical MRI data acquired at 4.7 or 9.4 T at two different sites in Australia. Male Sprague Dawley rats underwent MRI on Days 2, 9, 28, and 150 following moderate/severe traumatic brain injury (TBI) or sham injury as part of Project 1 of the NIH/NINDS‐funded Centre Without Walls EpiBioS4Rx project. Diffusion‐weighted and multiple‐gradient‐echo images were acquired, and outcomes included QSM, FA, and ADC. Acute injury measures including apnea and self‐righting reflex were consistent between sites. Mixed‐effect analysis of ipsilateral and contralateral corpus callosum (CC) summary values revealed a significant effect of site on FA and ADC values, which was removed following ComBat harmonization. Bland–Altman plots for each metric showed reduced variability across sites following ComBat harmonization, including for QSM, despite appearing to be largely unaffected by inter‐site differences and no effect of site observed. Following harmonization, the combined inter‐site data revealed significant differences in the imaging metrics consistent with previously reported outcomes. TBI resulted in significantly reduced FA and increased susceptibility in the ipsilateral CC, and significantly reduced FA in the contralateral CC compared with sham‐injured rats. Additionally, TBI rats also exhibited a reversal in ipsilateral CC ADC values over time with significantly reduced ADC at Day 9, followed by increased ADC 150 days after injury. Our findings demonstrate the need for harmonizing multi‐site preclinical MRI data and show that this can be successfully achieved using ComBat while preserving phenotypical changes due to TBI.
- Open Access
Epilepsy phenotype and its reproducibility after lateral fluid percussion‐induced traumatic brain injury in rats: Multicenter EpiBioS4Rx study project 1
Objective: This study was undertaken to assess reproducibility of the epilepsy outcome and phenotype in a lateral fluid percussion model of posttraumatic epilepsy (PTE) across three study sites.Methods: A total of 525 adult male Sprague Dawley rats were randomized to lateral fluid percussion‐induced brain injury (FPI) or sham operation. Of these, 264 were assigned to magnetic resonance imaging (MRI cohort, 43 sham, 221 traumatic brain injury [TBI]) and 261 to electrophysiological follow‐up (EEG cohort, 41 sham, 220 TBI). A major effort was made to harmonize the rats, materials, equipment, procedures, and monitoring systems. On the 7th post‐TBI month, rats were video‐EEG monitored for epilepsy diagnosis.Results: A total of 245 rats were video‐EEG phenotyped for epilepsy on the 7th postinjury month (121 in MRI cohort, 124 in EEG cohort). In the whole cohort (n = 245), the prevalence of PTE in rats with TBI was 22%, being 27% in the MRI and 18% in the EEG cohort (p > .05). Prevalence of PTE did not differ between the three study sites (p > .05). The average seizure frequency was .317 ± .725 seizures/day at University of Eastern Finland (UEF; Finland), .085 ± .067 at Monash University (Monash; Australia), and .299 ± .266 at University of California, Los Angeles (UCLA; USA; p < .01 as compared to Monash). The average seizure duration did not differ between UEF (104 ± 48 s), Monash (90 ± 33 s), and UCLA (105 ± 473 s; p > .05). Of the 219 seizures, 53% occurred as part of a seizure cluster (≥3 seizures/24 h; p >.05 between the study sites). Of the 209 seizures, 56% occurred during lights‐on period and 44% during lights‐off period (p > .05 between the study sites).Significance: The PTE phenotype induced by lateral FPI is reproducible in a multicenter design. Our study supports the feasibility of performing preclinical multicenter trials in PTE to increase statistical power and experimental rigor to produce clinically translatable data to combat epileptogenesis after TBI.
Open AccessEpilepsy phenotype and its reproducibility after lateral fluid percussion‐induced traumatic brain injury in rats: Multicenter EpiBioS4Rx study project 1
Objective: This study was undertaken to assess reproducibility of the epilepsy outcome and phenotype in a lateral fluid percussion model of posttraumatic epilepsy (PTE) across three study sites.Methods: A total of 525 adult male Sprague Dawley rats were randomized to lateral fluid percussion‐induced brain injury (FPI) or sham operation. Of these, 264 were assigned to magnetic resonance imaging (MRI cohort, 43 sham, 221 traumatic brain injury [TBI]) and 261 to electrophysiological follow‐up (EEG cohort, 41 sham, 220 TBI). A major effort was made to harmonize the rats, materials, equipment, procedures, and monitoring systems. On the 7th post‐TBI month, rats were video‐EEG monitored for epilepsy diagnosis.Results: A total of 245 rats were video‐EEG phenotyped for epilepsy on the 7th postinjury month (121 in MRI cohort, 124 in EEG cohort). In the whole cohort (n = 245), the prevalence of PTE in rats with TBI was 22%, being 27% in the MRI and 18% in the EEG cohort (p > .05). Prevalence of PTE did not differ between the three study sites (p > .05). The average seizure frequency was .317 ± .725 seizures/day at University of Eastern Finland (UEF; Finland), .085 ± .067 at Monash University (Monash; Australia), and .299 ± .266 at University of California, Los Angeles (UCLA; USA; p < .01 as compared to Monash). The average seizure duration did not differ between UEF (104 ± 48 s), Monash (90 ± 33 s), and UCLA (105 ± 473 s; p > .05). Of the 219 seizures, 53% occurred as part of a seizure cluster (≥3 seizures/24 h; p >.05 between the study sites). Of the 209 seizures, 56% occurred during lights‐on period and 44% during lights‐off period (p > .05 between the study sites).Significance: The PTE phenotype induced by lateral FPI is reproducible in a multicenter design. Our study supports the feasibility of performing preclinical multicenter trials in PTE to increase statistical power and experimental rigor to produce clinically translatable data to combat epileptogenesis after TBI.
- Open Access
A multi-channel TMS system enabling accurate stimulus orientation control during concurrent ultra-high-field MRI for preclinical applications
Monitoring cortical responses to neuromodulation protocols on preclinical models can elucidate fundamental mechanisms of brain function. Concurrent brain stimulation and imaging is challenging, usually compromising spatiotemporal resolution, accuracy, and versatility. Here we report a non-invasive brain stimulation system with electronic control of neuromodulation parameters in a 9.4-T magnetic resonance imaging (MRI) environment. In the imaging scanner, transcranial magnetic stimulation is delivered with a set of two coils and the MRI signals are recorded with a radiofrequency coil. The coil set provides millisecond-scale electronic control of the stimulus orientation with 1° resolution. Without physically rotating the coils, we evoked orientation-specific muscle responses after cortical stimulation on an anesthetized rat. We show that the stimulation pulses do not affect the anatomical imaging quality, and imaging signals are disrupted only if recorded before 10 ms after pulse delivery. Concurrent electronically targeted brain stimulation and neuroimaging sets the stage for the causal investigation of whole-brain network functions, endorsing more efficient treatment protocols.
Open AccessA multi-channel TMS system enabling accurate stimulus orientation control during concurrent ultra-high-field MRI for preclinical applications
Monitoring cortical responses to neuromodulation protocols on preclinical models can elucidate fundamental mechanisms of brain function. Concurrent brain stimulation and imaging is challenging, usually compromising spatiotemporal resolution, accuracy, and versatility. Here we report a non-invasive brain stimulation system with electronic control of neuromodulation parameters in a 9.4-T magnetic resonance imaging (MRI) environment. In the imaging scanner, transcranial magnetic stimulation is delivered with a set of two coils and the MRI signals are recorded with a radiofrequency coil. The coil set provides millisecond-scale electronic control of the stimulus orientation with 1° resolution. Without physically rotating the coils, we evoked orientation-specific muscle responses after cortical stimulation on an anesthetized rat. We show that the stimulation pulses do not affect the anatomical imaging quality, and imaging signals are disrupted only if recorded before 10 ms after pulse delivery. Concurrent electronically targeted brain stimulation and neuroimaging sets the stage for the causal investigation of whole-brain network functions, endorsing more efficient treatment protocols.
- Open Access
- 2 December 2022
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 23 (23) , 15208
Plasma Neurofilament Light Chain (NF-L) Is a Prognostic Biomarker for Cortical Damage Evolution but Not for Cognitive Impairment or Epileptogenesis Following Experimental TBI
Plasma neurofilament light chain (NF-L) levels were assessed as a diagnostic biomarker for traumatic brain injury (TBI) and as a prognostic biomarker for somatomotor recovery, cognitive decline, and epileptogenesis. Rats with severe TBI induced by lateral fluid-percussion injury (n = 26, 13 with and 13 without epilepsy) or sham-operation (n = 8) were studied. During a 6-month follow-up, rats underwent magnetic resonance imaging (MRI) (day (D) 2, D7, and D21), composite neuroscore (D2, D6, and D14), Morris-water maze (D35–D39), and a 1-month-long video-electroencephalogram to detect unprovoked seizures during the 6th month. Plasma NF-L levels were assessed using a single-molecule assay at baseline (i.e., naïve animals) and on D2, D9, and D178 after TBI or a sham operation. Plasma NF-L levels were 483-fold higher on D2 (5072.0 ± 2007.0 pg/mL), 89-fold higher on D9 (930.3 ± 306.4 pg/mL), and 3-fold higher on D176 32.2 ± 8.9 pg/mL after TBI compared with baseline (10.5 ± 2.6 pg/mL; all p < 0.001). Plasma NF-L levels distinguished TBI rats from naïve animals at all time-points examined (area under the curve [AUC] 1.0, p < 0.001), and from sham-operated controls on D2 (AUC 1.0, p < 0.001). Plasma NF-L increases on D2 were associated with somatomotor impairment severity (ρ = −0.480, p < 0.05) and the cortical lesion extent in MRI (ρ = 0.401, p < 0.05). Plasma NF-L increases on D2 or D9 were associated with the cortical lesion extent in histologic sections at 6 months post-injury (ρ = 0.437 for D2; ρ = 0.393 for D9, p < 0.05). Plasma NF-L levels, however, did not predict somatomotor recovery, cognitive decline, or epileptogenesis (p > 0.05). Plasma NF-L levels represent a promising noninvasive translational diagnostic biomarker for acute TBI and a prognostic biomarker for post-injury somatomotor impairment and long-term structural brain damage.
- 2 December 2022
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 23 (23) , 15208
Open AccessPlasma Neurofilament Light Chain (NF-L) Is a Prognostic Biomarker for Cortical Damage Evolution but Not for Cognitive Impairment or Epileptogenesis Following Experimental TBI
Plasma neurofilament light chain (NF-L) levels were assessed as a diagnostic biomarker for traumatic brain injury (TBI) and as a prognostic biomarker for somatomotor recovery, cognitive decline, and epileptogenesis. Rats with severe TBI induced by lateral fluid-percussion injury (n = 26, 13 with and 13 without epilepsy) or sham-operation (n = 8) were studied. During a 6-month follow-up, rats underwent magnetic resonance imaging (MRI) (day (D) 2, D7, and D21), composite neuroscore (D2, D6, and D14), Morris-water maze (D35–D39), and a 1-month-long video-electroencephalogram to detect unprovoked seizures during the 6th month. Plasma NF-L levels were assessed using a single-molecule assay at baseline (i.e., naïve animals) and on D2, D9, and D178 after TBI or a sham operation. Plasma NF-L levels were 483-fold higher on D2 (5072.0 ± 2007.0 pg/mL), 89-fold higher on D9 (930.3 ± 306.4 pg/mL), and 3-fold higher on D176 32.2 ± 8.9 pg/mL after TBI compared with baseline (10.5 ± 2.6 pg/mL; all p < 0.001). Plasma NF-L levels distinguished TBI rats from naïve animals at all time-points examined (area under the curve [AUC] 1.0, p < 0.001), and from sham-operated controls on D2 (AUC 1.0, p < 0.001). Plasma NF-L increases on D2 were associated with somatomotor impairment severity (ρ = −0.480, p < 0.05) and the cortical lesion extent in MRI (ρ = 0.401, p < 0.05). Plasma NF-L increases on D2 or D9 were associated with the cortical lesion extent in histologic sections at 6 months post-injury (ρ = 0.437 for D2; ρ = 0.393 for D9, p < 0.05). Plasma NF-L levels, however, did not predict somatomotor recovery, cognitive decline, or epileptogenesis (p > 0.05). Plasma NF-L levels represent a promising noninvasive translational diagnostic biomarker for acute TBI and a prognostic biomarker for post-injury somatomotor impairment and long-term structural brain damage.