A freely accessible, evidence based, objective system of analysis of posterior capsular opacification ; Evidence for its validity and reliability
Open Access
- 7 April 2005
- journal article
- research article
- Published by Springer Nature in BMC Ophthalmology
- Vol. 5 (1) , 9
Abstract
Background: The aim of this study was to develop a system of computerised analysis of digital images of posterior capsule opacification (PCO) that is evidence based, objective and freely available. The paper will present evidence for the reliability and validity of the developed system. Methods: The system of PCO analysis was developed considering current published evidence on visual significance of PCO and additional investigative analysis of PCO images. Details of the image processing and analysis steps are discussed and a final system that measures an entropy score weighted toward proximity to central areas is described. In order to assess validity, the systems ability to measure PCO progression is assessed along with the visual significance of its final computerised scores. Reliability of the system is also assessed. Results: The final system runs successfully and is simple to use. Analyses of PCO by the system show an ability to detect early progression of PCO as well as detection of visually significant PCO. Images with no clinical PCO produce very low scores in the analysis. Reliability of the system of analysis is shown to be satisfactory. Conclusion: This paper presents a system of PCO analysis that is evidence based, objective and clinically useful. Substantial evidence is provided for its validity and reliability.Keywords
This publication has 9 references indexed in Scilit:
- POCOmanJournal of Cataract & Refractive Surgery, 2004
- The Effect of Posterior Capsule Opacification on Visual FunctionInvestigative Ophthalmology & Visual Science, 2003
- Posterior capsule morphology determinants of visual functionGraefe's Archive for Clinical and Experimental Ophthalmology, 2003
- Removal of Reflections in the Photographic Assessment of PCO by Fusion of Digital Retroillumination ImagesInvestigative Ophthalmology & Visual Science, 2003
- Comparison of 4 methods for quantifying posterior capsule opacificationJournal of Cataract & Refractive Surgery, 2003
- Visual acuity and contrast sensitivity in different types of posterior capsule opacificationJournal of Cataract & Refractive Surgery, 2001
- Quantification of posterior capsular opacification in digital images after cataract surgery.2000
- Posterior capsular opacification after cataract surgeryEye, 1999
- Photographic image analysis system of posterior capsule opacificationJournal of Cataract & Refractive Surgery, 1997